Download Verification report

Transcript
7
Cable bending
Not available
8
Electrostatic discharge
IEC 61000-4-2:2001
Performance criterion: B
9
Radiated RF immunity
IEC 61000-4-3:2006
Performance criterion: A
10
Conducted radio
frequency
IEC 61000-4-6:2007
Performance criterion: A
11
Burst/Fast transients
IEC 61000-4-4:2004
Performance criterion: B
12
Surge voltage
IEC 61000-4-5:2005
Performance criterion: B
13
Radiated emission
Conducted emission
Power frequency
H-field immunity
CISPR 16-2-3:2006
Voltage dips and
interruptions
IEC 61000-4-11:2001
Performance criterion: B
14
15
16
CISPR 16-2-1:2008
IEC 61000-4-8:2001
Performance criterion: A
ditions, except for cracking of
black plastic part.
No malfunction was observed during the exposure. Further, no
damages or deteriorations were
observed during the visual inspection at standard atmospheric conditions.
No malfunction was observed during the exposure and the function
of the test objects was OK after
the exposure. Performance criterion: B.
No malfunction was observed during the exposure and the function
of the test objects was OK after
the exposure.
No malfunction was observed during the exposure, and the function
of the test objects was OK after
the exposure.
No malfunction was observed during the exposure and the function
of the test objects was OK after
the exposure.
No malfunction was observed during the exposure and the function
of the test objects was OK after
the exposure.
The radiated emissions were within the specified limits.
The conducted emissions were
within the specified limits.
No malfunction was observed during the exposure and the function
of the test objects as OK after exposure.
No malfunction was observed during the exposure and the function
of the test objects was OK after
the exposure.
During the EMC immunity testing the following generic acceptance criteria for compliance were in force:
 Performance Criterion A: (For continuous phenomena): The EUT shall continue
to operate as intended during and after the test. No degradation of performance
or loss of function is allowed as defined in the relevant equipment standard and
in the technical specification published by the manufacturer.
 Performance Criterion B: (For transient phenomena): The EUT shall continue to
operate as intended after the tests. No degradation of performance or loss of
function is allowed as defined in the technical specification published by the
manufacturer. During the test, degradation or loss of function or performance
LevelTec Verification Report
17