Table 7. Service Processor Error Codes (continued)
Error Code
Description
Action/ Possible Failing FRU
406B 020E
Wire tests detected memory pair A
fault
Memory Pair A, Location: P1-M1.1 x2
406B 0211
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.13
406B 0212
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.3
406B 0213
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.14
406B 0214
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.4
406B 021D
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.3 x4
406B 0221
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.11
406B 0222
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.5
406B 0223
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.12
406B 0224
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.6
406B 022D
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.5 x4
406B 0231
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.9
406B 0232
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.7
406B 0233
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.10
406B 0234
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.8
406B 023D
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.7 x4
406B 02FF
Wire tests detected memory failure
on riser card 1 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 57, and run
minimum configuration for further
isolation.
406B 0300
Wire tests detected processor card
fault
Processor card Location: P1-C1
406B 0301
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M8
406B 0302
Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
Chapter 5. Error Code to FRU Index
165