Download Aladin Square User manual - Scubapro
Transcript
if after Square has changed NOTE: the decompression schedule to reflect the missed gas switch, you descend again below the MOD for gas d, Square reintroduces gas d into the calculations and the decompression schedule changes accordingly. 2.5.1.4 2.5.1.2 Switching back to a gas mixture with lower oxygen concentration There may be situations in which you have to switch back to gas 1 from gas d. This can happen for instance if you want to descend again below the MOD for gas d, or if for instance you have run out of gas d during the decompression. At this point you can manually initiate the gas switch by pressing SEL button. Square will display the text gas 1, blinking. At this point press SEL button to confirm the switch. Square will display the text gas 1 and adapt the decompression schedule accordingly. 2.5.1.5 Gas switch not carried out at the planned depth If you fail to confirm the change to gas d within the 30 seconds of when Square suggested it, gas d is excluded from the decompression calculation and the decompression schedule is adapted accordingly, basically reflecting the fact that you will finish the dive using gas 1 only. 34 Manual gas switch at a depth deeper than its MOD There may be situations in which you have no other choice but to switch to a gas mixture although you are below the MOD for that mixture. Square does not prevent you from doing this, but the MOD alarm will immediately start. Press SEL button to start the gas switch procedure. Square will show the text gas d blinking on the display. This helps you verify that you are performing a switch to a safe gas. At this point press SEL button to confirm the switch. 2.5.1.6 2.5.1.3 Delayed gas switch You can catch up on a planned gas mixture switch at any time by selecting the gas manually. Press SEL button to start the gas switch procedure. Square will show the text gas d and its MOD blinking on the display. This helps you verify that you are performing a switch to a safe gas. At this point press SEL button to confirm the switch. Square will display the text gas d without blinking and adapt the decompression schedule accordingly. Submerging below the MOD after a gas switch If after having switched to gas d you inadvertently drop again below the MOD for that mixture, the MOD alarm will immediately start. Either switch back to gas 1, or ascend above the MOD for gas d. 2.6 Warnings and alarms Square can alert you of potentially dangerous situations via warnings and alarms. You can only modify the warning and alarm settings via PC interface. ALADIN SQUARE USER MANUAL