Download PC wiring system
Transcript
VALVES GENERAL CATALOG WIRING SYSTEM INDEX Features Wide Variation Units Application Examples Connection Examples Features of Branch Units Features of Terminal Blocks Handling Instructions and Precautions Specifications Okiflex Cable Crimping Tool Check Unit Order Codes Cable Assembly Order Codes Connection Map Connection Example between Branch Unit and Equipment PC WIRING SYSTEM Discontinued 985 987 989 990 991 992 993 995 1021 1022 1023 1025 1028 1033 1035 Caution Before use, be sure to read the “Safety Precautions” on p. 31. 984 Easy, Quick, and Simple Wiring for Valves and Sensors! ●Programmable controller 32 inputs 32 inputs 32 outputs 32 outputs ●Compatible PC manufacturers • OMRON • YASKAWA ELECTRIC • Mitsubishi Electric • SHARP • Fuji Electric FA Components • YOKOGAWA ELECTRIC • & Systems • Matsushita Electric Works • Hitachi • KEYENCE • TOSHIBA • KOYO ELECTRONICS INDUSTRIES ※For details, see p.1033. − Outputb + Inputa Power supply DC24V Inputa a16 outputs a16 outputs ■Branch unit (For output) 32 outputs→16 outputs×2 (direct connecting type) p.996 Fujitsu FCN connector or MIL standard connector 32 outputs 32 inputs ■Branch unit (For output) 32 outputs→16 outputs×2 Discontinued (mountable on DIN rail) ■Branch unit (For input) 32 inputs→16 inputs×2 (mountable on DIN rail) Converts the 40-pin, 32 inputs pin arrangement that varies from one company PC to another, to the commonly used 16 inputs, 20-pin arrangement. p.997 Converts the 40-pin, 32 outputs pin arrangement that varies from one company PC to another, to the commonly used 16 outputs, 20-pin arrangement. 16 inputs 16 inputs 16 outputs 16 outputs p.999 ■32-input unit Achieves space savings. p.1001 Cascade connection Uses easy to handle crimping type connector 8 inputs 8 inputs ■16-input unit ■8-input unit ■8-input unit (mountable on DIN rail) p.1005 (mountable on DIN rail) p.1005 (Box-mounting type) p.1006 Photo-electric switches, proximity switches, sensor switches for cylinders, limit switches, and other input devices can be connected. 985 Branch Unit Offers Commonality ●The branch unit branches off the 32-I/O of the various PC manufacturers into the 16-I/O common pin arrangement. ●Converts to common pin arrangement to ensure connection with the Koganei manifold type solenoid valves, relay terminals, etc. of other companies, without undue concern for pin arrangement. ●Can supply power to PC I/O units. ●Branch units compatible with the I/O connectors of all PC manufacturers are available. Parallel Type for Simplicity ●Unlike with serial transmission, there is no need to worry about transmission delay time. ●Visually and intuitively easy to understand, for simple maintenance during setup, debugging and breakdowns. ●No need for expensive systems; cuts initial costs as well. Increased Wiring Savings ●Special cable with power line is a remarkable flat cable that incorporates a flat cable and the power line within a single insulation, eliminating the need for separate wiring of power line. ●Cutting the special cable at any point and one operation crimping connection help to achieve wiring savings equivalent to serial transmission systems. ●One operation crimping connector helps to standardize wiring work, to prevent incorrect wiring, and to vastly improve operations efficiency. Solenoid valves F Series (F10) Cascade connection 8 outputs 8 outputs Discontinued Solenoid valves F series (F15) ■Connector type 8-output p.1015 unit (main unit) ■Compatible manifold type solenoid valve ■Okiflex cable Special cable includes a flat cable and power line in a single insulation. 20 leads and 40 leads are available. p.1021 Solenoid valves F series With wiring specification -F201 (Positive common specification) FM-SOLID MANIFOLD X80M, X88M series With wiring module FMCR-F201, FMC-F201 (Positive common specification) ※Maximum control solenoids: 16 For details, see p.993. ■16-output common reduction unit Unit reduces common terminals to achieve superior space-saving benefits. PC WIRING SYSTEM ※32-output unit is also available. p.1019 ■16-output unit (mountable on DIN rail) p.1007 Solenoid valves, relays, lamps, and other output equipment can be connected. ※8 and 32-output units are also available. (The branch unit is not used when using the 32-output unit.) Solenoid valves GF series (GF10) ※Pre-wired common 986 PC Wiring System Wide Variation Units Branch unit ●The branch unit branches off the 32-I/O of the various PC manufacturers into the 16-I/O common pin arrangement. ●Converts to the common pin arrangement to ensure connection with the Koganei manifold type solenoid valves, relay terminals etc. of other companies, without undue concern for pin arrangement. ●Can supply power to PC I/O units. ●Branch units compatible to the I/O connectors of all PC manufacturers are available. ●A direct connecting type with direct plug-in to the I/O connector is also available. FCN connector type PC direct connecting type MIL connector type DIN rail mounting type ※For details, see p.995∼1000. 32-input/output unit ●Compatible to the various companies’ PC 32- and 64-I/O connectors. Offers more space savings than conventional terminal blocks. ●Color markers are also provided for easy identification of terminal block No. markings. Discontinued FCN connector type MIL connector type DIN rail mounting type ※For details, see p.1001∼1004. 8- and 16-input/output unit ●8- or 16-I/O unit. ●Used in combination with branch unit. ●The 8-input/output unit is equipped with 2 connectors, and can be added-on by using cascade connections. In addition, a jumper switch allows “HI” or “LO” address settings. ●A metal box mounting type is also available to enable installation outside of control panels. DIN rail mounting type Box-mounting type ※For details, see p.1005∼1008. Connector type 8- and 16-input/output unit ●A plug connector allows connection to input/output equipment. ●8- or 16-I/O unit. ●Used in combination with branch unit. ●A connector type 8-input/output unit (main unit) is equipped with 2 connectors, and can also be connected by using a cascade connection to subunits, or manifold solenoid valves, etc. (Main unit) DIN rail mounting type ※For details, see p.1013∼1016. 987 (Sub-unit) 8 LO-only input/output unit 8 HI-only input/output unit ●8-I/O unit. ●Unit fixed at LO/HI eliminates need for installing the jumper (short-circuit socket). ●Used in combination with branch unit. ●The unit is equipped with 2 connectors, and can be added-on by using cascade connections. ●A metal box mounting type is also available to enable installation outside of control panels. DIN rail mounting type Box-mounting type ※For details, see p.994, 1009∼1012. 16- and 32-output common reduction unit ●Unit reduces common terminal blocks for excellent space-saving benefits. Includes a 16-output type and a 32-output type compatible with all companies’ PCs. ●32-output unit is compatible with all companies’ PC 32- and 64-output connectors. Color markers are also provided for easy identification of terminal block No. markings. ●Use the 16-output unit in combination with a branch unit. (16-output unit) (32-output unit) Discontinued FCN connector type MIL connector type DIN rail mounting type ※For details, see p.1017∼1019. Cable assembly (Made to order) ●Various cable assemblies with crimped connectors onto Okiflex cables are also available. ●Cable lengths offered from 0.5m [1.65ft.] to 20m [65.6ft.], by the 0.5m [1.65ft.] pitch. ※For details, see p.1028∼1032. ●Various kinds of crimping connectors ●Okiflex cable Remarkable cable incorporates a flat cable with power line within a single insulation for easy crimping onto a connector. ●Crimping tool Crimping tools are compatible with all crimping connectors used in PC wiring systems. ●Check unit Allows easy function checking of various units, manifold type solenoid valves, and sensors. ※For details, see p.1021∼1026. Various connectors Okiflex cable Crimping tool Check unit PC WIRING SYSTEM Associated products 988 PC Wiring System Application Examples ducts onal pro Conventi k like this loo e u us n yo Whe wiring PC Control panel Control panel 16-I/O×2 ● For connections between a programmable controller and input or output equipment. 32-I/O e a PC Effectiveness PC 32-input or output unit ●Reduces wiring man-hours. ●Prevents wiring mistakes. ●Reduces space occupied. Input or output equipment Input or output equipment Remark: Power supply wiring is omitted from the diagram. ●For connections to manifold type solenoid valves, etc. Manifold type solenoid valve (16 solenoids) 32 outputs→16 outputs×2 Discontinued Manifold type solenoid valve (16 solenoids) Effectiveness ●Reduces wiring man-hours. ●Prevents wiring mistakes. ●Simple wiring work by using connectors ●Also enables commercially available relay terminals, etc. to connect. PC Note: Solenoid valves are -F201 flat cable connector specification. 32-I/O Branch unit(for output) 32 outputs→16 outputs×2 Note: Power supply wiring is omitted from the diagram. ●For inputs from sensor switches, etc. 8-input unit (Box-mounting type) 32 inputs→16 inputs×2 16 inputs→8 inputs×2 Cascade connection 8-input unit (Box-mounting type) 16-input unit (Box-mounting type) PC 32-I/O Branch unit (for input) 32 inputs→16 inputs×2 989 Effectiveness ●Reduces wiring man-hours. ●Prevents wiring mistakes. ●Compatible with fewer I/O. Remark: Power supply wiring is omitted from the diagram. PC Wiring System Connection Examples DC24V Power supply PC Branch unit (for input) 32-input unit Branch unit (for output) Note 1 Note 1 Wiring connection example Power line Discontinued Crimp type terminal Crimp type sleeve Okiflex cable Heat-shrink tube Red colored wire Flat cable Crimping connector Note 3 Triangle mark 32-output unit 16-input unit 8-input unit Note 2 Note 1 Relay terminal 8-output unit Note 2 Note 1 8 manifold type solenoid valves Notes: 1. The rated current for each unit is a maximum of 2.0A (a maximum of 1.0A for the 8-input/output unit). When the transit current in each unit exceeds 2.0A (a maximum of 1.0A for the 8-input/output unit), use the same power supply terminal to connect the 2 power lines, and do not let current flow through the unit. 2. When connecting the 8-input/output unit to manifold solenoid valves and relay terminals, as shown in the diagram above, set the unit jumper to the “HI” side. 3. For the crimping of each type of a connector, see the separately issued User’s Manual for PC wiring systems (Document No.HV002). 990 PC WIRING SYSTEM 16 manifold type solenoid valves Features of Branch Units in PC Wiring System ■Benefit No.1 Use of a branch unit allows branching of 32-I/O→16-I/O×2. Branch units convert the 32-I/O, 40-pin arrangement that varies from one company PC to another, to the commonly used 16-I/O, 20-pin arrangement. Because this pin arrangement follows the Koganei manifold solenoid valve series (wiring specification is the -F201 type, with positive common specification), and the various common specifications for peripheral equipment of various companies on p.1035, connections can be made without undue concern for connector pin arrangement, etc. ■Benefit No.2 Use of a branch unit enables power supply to the PC side I/O units. Okiflex cable with Branch unit (for output) PC side I/O unit integral power line 40 leads 32 outputs (Sink type) 8- and 16-output unit, or manifold type solenoid valve, etc. +− C CN1 1 2 3 4 RS- 00 01 02 ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ A B A B A B ・ ・ ・ ・ ・ − + COM ※Circuit details, etc. have been omitted. ・ +− DC24V + Power supply − ■Benefit No.3 Discontinued Use of a branch unit reduces voltage drops, and enables long distance wiring. ●Example of connection with large voltage drop PC side I/O unit (Output) Wiring cannot extend for a long distance! Flat cable General terminal block COM Power supply for internal circuit ※Circuit details, etc. have been omitted. + DC24V Power supply − Solenoid Power line (Separate wiring) ●Since the common current line with the largest flow passes an exceedingly long distance to return to the negative polarity of the power supply, the voltage drop increases quite a large amount. ●Example of connection using a branch unit to reduce the voltage drop Install a branch unit near the I/O unit, and use the branch unit’s power supply terminal. PC side I/O unit (Output) Branch unit (For output) Okiflex cable with integral power line Wiring can go long distance! 16-output unit COM Power supply for internal circuit ※Circuit details, etc. have been omitted. +− DC24V + Power supply − Solenoid ●Since the common current line with the largest flow can be routed an exceedingly short distance to return to the negative polarity of the power supply, the voltage drop remains small, and longer distance wiring is possible. In addition, use of an Okiflex cable eliminates the need for separate wiring for the power line. 991 Features of Terminal Blocks Used in PC Wiring System For PC wiring systems, screw-pushed terminal blocks made by the major terminal block manufacturer Weidmuller are used. 1. A large contact surface and high contact pressure guarantee highly reliable and stable contact in ambient environments. 2. The pitch between terminals on the terminal block is just 5.08mm [0.200in.], as compared to the generally used pitch 7.62 ∼12mm [0.300∼0.472in.], offering large space savings. This design saves a lot of space when using the same number of terminals, or enables more terminals to be used in the same space, and reduces wiring work for common. 3. Since even stranded wire ensures high reliability without the use of crimp type terminals, the crimping process has not been required, reducing wiring man-hour to less than one-third than before. It also accepts bar terminals, crimp type sleeves, and other conventional wiring parts. 4. Because the electric contacts are not exposed, it makes use without covers (which are all too often lost during maintenance, anyway). In addition, the construction is designed to avoid terminal screw dropping losses. 5. When tightening the terminal screw, the effects of a double nut maintain high vibration resistance, and prevent looseness in the screw. In addition, a special heat treatment of the clamp improves mechanical stress. 6. Meets the UL, CSA, VDE and other standards (terminal block alone). ■Double Nut Effect Tightening the terminal screw generates a reaction force that causes the bent portion near the top of the clamp to restore, thus achieving the double nut effect. Before tightening After tightening Discontinued ■Easy-to-Use Common Terminal The input or output unit provides a large number of positive (+) and negative (−) common terminals. Use of an input unit also eases connections to the 3lead wire type sensor switch, etc. No need to provide a separate common terminal block Power line(+):Brown Limit switch Blue Brown Blue Black Brown Power line(−):Blue 2-lead wire type proximity switch 3-lead wire type sensor switch for cylinder ■Terminal Block Screw Use of new Phillips type head screws has further eased work. Conventional product New type Caution: For the terminal screw tightening torques, see each specifications. 992 PC WIRING SYSTEM ● Photo shows a 16-input unit. Handling Instructions and Precautions Precautions for Use 1. Always use a voltage of DC24V or less. 2. After wiring is complete, check for incorrect connections before turning on the power. 3. Never disconnect any connectors when the power is on. Also, never apply unnecessary stress on the connectors. 4. Use a dedicated crimping tool when performing cable crimping work. In addition, always check the crimped conditions before operation. 5.The Okiflex cable is a cable for fixed wiring. Never apply any repetitive bending or tensile force to it. About the Flat Cable Connector Pin Arrangement Branch units in the PC wiring system convert the 32-I/O, 40-pin arrangement that varies from one company PC to another, to the commonly used 16-I/O, 20-pin arrangement. This pin arrangement accommodates the PC wiring system’s 8- and 16-input/output units (excluding input/output units for the Mitsubishi Electric FX2 and FX2C series), the Koganei manifold type solenoid valve series, and the various common specifications for peripheral equipment of various companies on p.1035. Take particular care about connecting to any other peripheral equipment. Cautions: 1. The “positive polarity” and “negative polarity” positions differ between the input system and output system. Since an improper connection between the input system and output system equipment can cause a “short circuit”, take particular care for this. Cautions: 2. Although the pin arrangement varies between the Koganei manifold and PC wiring system, the physical arrangement characteristics are the same. For connection to other companies’ peripheral equipment, use the triangle mark and nose position as the reference. ●For input systems Indication example 1 Indication example 2 Actual arrangement 20 leads flat cable No. 1 wire(Red mark) Triangle mark 10 9 8 7 6 5 4 3 2 1 20 19 18 17 16 15 14 13 12 11 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 − + 07 06 05 04 03 02 01 00 − + 15 (F) 14 (E) 13 (D) 12 (C) 11 (B) 10 (A) 09 08 − + 15(F) 14(E) 13(D) 12(C) 11(B) 10(A) 09 08 Nose − + 07 06 05 04 03 02 01 00 Discontinued ●For output systems Indication example 1 Indication example 2 Actual arrangement 20 leads flat cable No. 1 wire(Red mark) Triangle mark 10 9 8 7 6 5 4 3 2 1 20 19 18 17 16 15 14 13 12 11 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 + − 07 06 05 04 03 02 01 00 + − 15 (F) 14 (E) 13 (D) 12 (C) 11 (B) 10 (A) 09 08 + − 15(F) 14(E) 13(D) 12(C) 11(B) 10(A) 09 08 Nose + − 07 06 05 04 03 02 01 00 Connections to Koganei Manifold Type Solenoid Valves When using a branch unit to connect the Koganei manifold type solenoid valves, see the table below for compatible manifolds: Compatible manifold Solenoid valves F series Wiring specification Positive common specification Wiring specification -F201 FM-SOLID MANIFOLD Positive common specification Wiring module FMCR-F201 X80M series FM-SOLID MANIFOLD Positive common specification Wiring module FMC-F201 X88M series 1. Pin arrangement of connector 2. Detailed diagram of wiring systems ●Solenoid valves F series ●Positive common X80M series Flat cable connector -F201 ●FM-SOLID MANIFOLD X80M, X88M series Flat cable connector FMCR-F201, FMC-F201 Power supply terminal Triangle mark Built-in to the base LED for power supply 10, 20 1 Solenoid 8 11 18 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 9, 19 1∼8 11∼18 9,19 10, 20 : Control pins : Control pins : (−) pins (short-circuited within module) : (+) pins (short-circuited within module) Notes: 1. The connector pin numbers are assigned for the sake of convenience. Use the ▼ mark as the reference. 2. While the pin location identification method differs from the PC wiring system, the arrangement is equivalent in real usage. Reverse connection protection diode Solenoid valves F series/X88M series 10, 20 Power supply terminal Solenoid LED for power supply 1 8 11 Solenoid 18 9, 19 Reverse connection protection diode 993 Precautions for Use of the 8- and 16-Input/Output Units Precautions for Use of the Connector Type Input/Output Unit (DIN rail mounting type, Box-mounting type) 1. About cascade connections 1. About the nameplate Every PC manufacturer has its own way of assigning I/O addresses. A general use (can be used with any manufacturer) nameplate kit is available. Cut it as required, and then fit it into the terminal nameplate portion. Fit the nameplate so that the address runs from the left of the ▲ mark on the circuit board to right to increase. The connector type 8-input/output unit can be used in cascade connections between main units and sub-units, or in cascade connections between main units and other equipment. Caution: As the connector type input/output unit does not include a jumper (short-circuit socket), caution should be exercised when selecting a product. ●Connection example for cascade connectionsNote 3 2. About cascade connections (8-input/output unit) For cascade connections, use the jumper (short-circuit socket) to assign the addresses to either the “LO” side 0 ∼7 or the “HI” side 8∼F(15). In setting the “LO” side address, the “LO” side is shorted. It has been set to the “LO” side when shipped from the factory. 7 6 F E 7 6 F E 1 0 9 8 1 0 9 8 L H L q First unit: Connector type 8-input/output unit (main unit) Second unit: Connector type 8-input/output unit (sub-unit) Connector type 8-input/output unit (main unit) FMA-TC1108 FMA-TC1008 Connector type 8-input/output unit (sub-unit) FMA-TD1108 FMA-TD1008 H “LO” Setting “HI” Setting Cautions: When the 8-input/output unit is used for 2 cascade connections, do not set each jumper setting as LO and LO, or HI and HI, for not sharing the same address. Cautions: (In the case of input, it becomes OR circuits with 2 sensors, and operating problems will occur.) CN-PC2Note 4 CN-PC1 Address CN-PC1 Address 0∼7 8∼F (15) w First unit: Connector type 8-output unit (main unit) Second unit: Manifold ●Connection example for cascade connectionsNote 1 q First unit: 8-input/output unit Second unit: 8-input/output unit Connector type 8-output unit (main unit) FMA-TC1008 Manifold mounted F201 When the first 8-input/output unit is set to the “LO” side address, set the second 8-input/output unit to the “HI” side. CN-PC1 8-input/output unit CN1 FMA-TM1108 (-MB) FMA-TM1008 (-MB) CN-PC2Note 4 8-input/output unit FMA-TM1108 (-MB) FMA-TM1008 (-MB) Discontinued Jumper setting Address CN2 Note2 CN1 Jumper setting Address LO 0∼7 Address HI 8∼F (15) 0∼7 Address 8∼F (15) Notes: 3. For cascade connections, see the circuit diagram. 4. The CN-PC1 and CN-PC2 do not have identical pin arrangements. (For details, see the circuit diagram.) w First unit: 8-output unit Second unit: Manifold For the manifold, use the “LO” side address. Therefore, use the “HI” setting for the 8-output unit. Note: When the manifold address is set on the “HI” side, the address is 8 ∼F(15), or when the manifold is connected to the first unit, the manifold should be a special specification. Consult us. Manifold mounted F201 Jumper setting Address Note2 For the housings and terminals for the mounted wafer (3 pins), use the items shown below: Koganei model: FMA-BM03A (10 housings and 30 terminals make 1 set.) ●Applicable housing CN2 Made by Molex Japan Model No. 51103-0300 HI 8∼F (15) Jumper setting Address Without setting 0∼7 Notes:1. For cascade connections, see the circuit diagram. 2. CN1 and CN2 have identical pin arrangements. (For details, see the circuit diagram.) 3. About the 8 LO/HI-only input/output unit Unit for fixed LO/HI that does not require jumper (short-circuit socket) settings. ●LO-only unit FMA-TJ1108, FMA-TJ2108 FMA-TJ1008, FMA-TJ2008 Address allocation is fixed to the “LO” side (0∼7). ●Applicable terminal Made by Molex Japan Model No. 50351-8100 Applicable wire Lead wire size : AWG No.28...22 Insulation outer diameter : φ1.15∼φ1.8mm [φ0.0453∼φ0.071in.] Exposed wire length : 2.3∼2.8mm [0.091∼0.110in.] PC WIRING SYSTEM CN1 8-output unit FMA-TM1008 (-MB) 2. About the 3-pin connector Applicable crimping tool Made by Molex Japan Model No. 57295-5000 Extractor Model No. 57309-6000 ●HI-only unit FMA-TK1108, FMA-TK2108 FMA-TK1008, FMA-TK2008 Address allocation is fixed to the “HI” side (8∼F(15)). 994 Branch Unit, Programmable Controller Direct Connecting Type For OMRON, Input/For Mitsubishi Electric, Input ●Branch unit (Input)[For OMRON] ●FMA-TF3120-OR ●Branch unit (Input)[For Mitsubishi Electric] ●FMA-TF3120-MBA, FMA-TF3120-MBB Dimensions Dimensions (mm) ●FMA-TF3120-MBA 18.2 18.2 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 12 2 21 13 14 22 1A 1F 13 13 3 CN0 ※ FCN-364J040 [Fujitsu] + A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 Discontinued 1B 11 1 70.1 70.1 B3 B4 B5 A2 14 CN1 B2 A1 12 14 15 4 5 23.1 27.4 16.5 LPA2/2 [Nihon Weidmuller] B1 18 1C CN2 CN2 CN2 CN0 FCN-364J040 [Fujitsu] 20 (5.2) 23.1 27.4 16.5 Circuit diagram LPA2/2 [Nihon Weidmuller] 11 IN CN1 CN1 (5.2) 23.1 27.4 Circuit diagram 10 18.2 IN IN (5.2) 16.5 + ●FMA-TF3120-MBB 70.1 (mm) 23 15 16 24 19 1E 12 17 16 17 6 7 25 19 1A 1B 1C 1D 1E 28 29 26 2A 2B 2C 2D 2E 18 19 8 9 10 2F 20 21 22 23 24 25 26 11 13 14 16 17 12 15 27 27 18 18 1D 11 16 1F 17 2C 1015 20 10 2B 11 1 JM1P-0202 [IDEC Izumi] CN1 12 2 2A 2F 23 24 13 3 14 15 4 5 29 2E 22 27 16 6 17 7 28 2D 21 26 18 8 19 9 1C 1A 1F 14 20 10 11 1 JM1P-0202 [IDEC Izumi] CN2 Specifications 1B 20 25 13 12 2 13 3 14 15 4 5 19 1E 12 17 16 17 6 7 28 29 19 1A 1B 1C 1D 1E 2A 2B 2C 2D 2E 18 1D 11 16 18 19 8 9 2C 1015 2B 11 1 JM1P-0202 [IDEC Izumi] CN1 12 2 2A 2F 23 24 20 10 2F 1F 13 3 14 15 4 5 29 2E 22 27 16 6 17 7 28 2D 21 26 18 8 19 9 20 25 20 10 JM1P-0202 [IDEC Izumi] CN2 ※Differs from Mitsubishi Electric’s pin arrangement identification method. Parts Branch unit (Input) Branch unit (Input) Model FMA-TF3120-OR FMA-TF3120-MBA, FMA-TF3120-MBB OMRON Mitsubishi Electric PC manufacturer Compatible PC Compatible with 32-input model Compatible with 64-input model (32-input×2) C200H-ID216 A1SX41 C500-ID219, C200H-ID217 AX42, A1SX42Note DC24V Rated voltage Rated current Dielectric strength Tightening torque for the terminal screw AWG 0.3A/input, 2A/unit 0.3A/input, 2A/unit AC250V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) 7mm [0.276in.] LPA2/2〈Made by Nihon Weidmuller〉 FCN-364J040〈Made by Fujitsu〉 Installed connector (20 pins, half pitch) JM1P-0202〈Made by IDEC Izumi〉 Mating connector (20 pins, half pitch) JM1S-0203〈Made by IDEC Izumi〉 Operating temperature range Mass −25∼55°C [−13∼131°F] 25g [0.88oz.] Note : When using with the Mitsubishi Electric A1SX42, use it in combination with one FMA-TF3120-MBA and one FMA-TF3120-MBB. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 995 Branch Unit, Programmable Controller Direct Connecting Type For OMRON, Output/For Mitsubishi Electric, Output ●Branch unit (Output)[For OMRON] ●FMA-TF3020-OR ●Branch unit (Output)[For Mitsubishi Electric] ●FMA-TF3020-MBA, FMA-TF3020-MBB Dimensions Dimensions (mm) ●FMA-TF3020-MBA 18.2 18.2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 12 2 21 13 14 22 1A 1F 13 13 3 14 15 4 5 23.1 27.4 16.5 CN0 ※ FCN-364J040 [Fujitsu] + A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 Discontinued 12 1B 11 1 70.1 70.1 B2 A1 14 CN1 B1 18 1C (5.2) 23.1 27.4 LPA2/2 [Nihon Weidmuller] CN0 FCN-364J040 [Fujitsu] 20 CN2 CN2 CN2 (5.2) 16.5 Circuit diagram LPA2/2 [Nihon Weidmuller] 11 OUT CN1 CN1 23.1 27.4 Circuit diagram 10 18.2 OUT OUT (5.2) 16.5 + ●FMA-TF3020-MBB 70.1 (mm) 23 15 16 24 19 1E 12 17 25 19 1A 1B 1C 1D 1E 28 29 16 17 6 7 18 19 8 9 20 21 22 23 24 25 26 11 13 14 16 17 27 17 26 2A 2B 2C 2D 2E 10 2F 12 15 18 27 18 1D 11 16 1F 2C 1015 20 10 2B 11 1 JM1P-0202 [IDEC Izumi] CN1 12 2 2A 2F 23 24 13 3 14 15 4 5 29 2E 22 27 16 6 17 7 18 8 1C 28 2D 21 26 19 9 20 10 11 1 1A 1F 13 12 2 13 3 14 15 4 5 19 1E 12 17 16 17 6 7 28 29 2A 2B 2C 2D 2E 19 1A 1B 1C 1D 1E 18 1D 11 16 18 19 8 9 2C 1015 2B 12 11 2 1 20 10 2F 1F 2A 2F 23 24 JM1P-0202 [IDEC Izumi] CN1 JM1P-0202 [IDEC Izumi] CN2 Specifications 1B 14 20 25 A2 A1 13 3 14 15 4 5 29 2E 22 27 16 6 17 7 28 2D 21 26 18 8 19 9 20 25 20 10 JM1P-0202 [IDEC Izumi] CN2 ※Differs from Mitsubishi Electric’s pin arrangement identification method. Parts Branch unit (Output) Branch unit (Output) Model FMA-TF3020-OR FMA-TF3020-MBA, FMA-TF3020-MBB OMRON Mitsubishi Electric PC Compatible with 32-output model Compatible with 64-output model (32-output×2) C200H-OD218 A1SY41 C500-OD213, C200H-OD219 AY42, A1SY42Note DC24V Rated voltage Rated current Dielectric strength Tightening torque for the terminal screw AWG 0.3A/output, 2A/unit 0.3A/output, 2A/unit AC250V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) 7mm [0.276in.] LPA2/2〈Made by Nihon Weidmuller〉 FCN-364J040〈Made by Fujitsu〉 Installed connector (20 pins, half pitch) JM1P-0202〈Made by IDEC Izumi〉 Mating connector (20 pins, half pitch) JM1S-0203〈Made by IDEC Izumi〉 Operating temperature range Mass PC WIRING SYSTEM PC manufacturer Compatible −25∼55°C [−13∼131°F] 25g [0.88oz.] Note : When using with the Mitsubishi Electric A1SY42, use it in combination with one FMA-TF3020-MBA and one FMA-TF3020-MBB. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 996 For the circuit diagrams and specifications of branch units for other manufacturers, consult us. ●Branch unit (Input) ●FMA-TF4120-OR ●FCN connector type ●Branch unit (Input) ●FMA-TE4120-OR ●MIL connector type Dimensions Dimensions CN1 10.5 CN0 28.3 IN OUT CN2 8 7 6 5 RS C2 4.1 45 28.3 CN0 RS 103 CN1 CN2 49 5.1 (3.5) 45 10.5 16.7 10.5 C1 103 16.7 10.5 (mm) 4.1 (mm) 4 3 2 1 Branch Unit, DIN Rail Mounting Type For OMRON, Input 49 5.1 (3.5) 50.5 5 4.5 4.5 50.5 5 5 Circuit diagram Circuit diagram CN0 FCN-364P040 [Fujitsu] LPA1/2 [Nihon Weidmuller] + B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 18 11 20 1F 17 LPA1/2 [Nihon Weidmuller] B1 10 1E 16 1D 15 5 19 1A 1B 1C 1D 1E 28 29 CN0 FL40A2MS [Oki Electric Cable] LPA1/2 [Nihon Weidmuller] + + LPA1/2 [Nihon Weidmuller] 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1F 18 19 1A 1B 1C 1D 1E 28 29 Discontinued 12 21 13 22 1C 14 14 23 1B 13 15 16 24 25 1A 12 17 26 19 11 10 2A 2B 2C 2D 2E 11 12 20 18 2F 27 2E 26 14 15 16 2D 25 24 2C 2B 23 22 2A 29 21 28 1F 17 20 1E 16 21 1D 15 22 1C 14 23 1B 13 24 25 1A 12 26 19 11 1F 17 2F 27 10 13 + 2A 2B 2C 2D 2E 2F 27 18 2F 27 10 26 2E 2D 25 2C 24 2B 23 22 2A 29 21 28 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 Specifications Parts Branch unit (Input) FCN connector type Branch unit (Input) MIL connector type Model FMA-TF4120-OR FMA-TE4120-OR PC manufacturer Compatible PC OMRON Compatible with 32-input model C200H-ID216, CQM1-ID213 Compatible with 64-input model (32-input×2) C500-ID219, C200H-ID217 Rated voltage DC24V Rated current 0.3A/input, 2A/unit AC500V r.m.s. Dielectric strength Tightening torque for the terminal screw 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 AWG Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) Installed MIL connector (20 pins) Mating connector (40 pins) Mating MIL connector (20 pins) LPA1/2〈Made by Nihon Weidmuller〉 FCN-364P040〈Made by Fujitsu〉 FL20A2MS〈Made by Oki Electric Cable〉 FCN-367J040〈Made by Fujitsu〉 Note FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] Operating temperature range Mass FL40A2MS〈Made by Oki Electric Cable〉Note 85g [3.00oz.] 80g [2.82oz.] : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 997 For the circuit diagrams and specifications of branch units for other manufacturers, consult us. ●Branch unit (Input) ●FMA-TF4120-MB ●FCN connector type ●Branch unit (Input) ●FMA-TE4120-MB ●MIL connector type Dimensions Dimensions CN1 10.5 CN0 28.3 IN OUT CN2 8 7 6 5 RS C2 4.1 45 28.3 CN0 RS 103 CN1 CN2 49 5.1 (3.5) 45 10.5 16.7 10.5 C1 103 16.7 10.5 (mm) 4.1 (mm) 4 3 2 1 Branch Unit, DIN Rail Mounting Type For Mitsubishi Electric, Input 49 5.1 (3.5) 50.5 5 4.5 4.5 50.5 5 5 Circuit diagram Circuit diagram LPA1/2 [Nihon Weidmuller] A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 20 21 22 23 24 25 26 11 13 14 16 17 1E 16 1D 15 1C 14 + + LPA1/2 [Nihon Weidmuller] CN0 FL40A2MS [Oki Electric Cable] 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 20 21 22 23 24 25 26 15 1B 13 1A 12 19 11 29 2A 2B 2C 2D 2E 2F 10 19 1A 1B 1C 1D 1E 18 12 13 14 15 16 18 2E 26 2D 25 24 2C 2B 23 22 2A 29 21 1F 28 17 20 1E 16 1D 15 1C 14 1B 13 1A 12 19 11 28 29 2A 2B 2C 2D 2E 19 1A 1B 1C 1D 1E 2F 17 1F 2F 27 10 11 + 27 Discontinued 12 18 1F A2 A1 LPA1/2 [Nihon Weidmuller] 27 28 10 17 LPA1/2 [Nihon Weidmuller] CN0 ※ FCN-364P040 [Fujitsu] + 5 18 1F 2F 27 10 26 2E 2D 25 24 2C 23 2B 22 2A 29 21 28 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 FL20A2MS [Oki Electric Cable] CN2 ※Differs from Mitsubishi Electric’s pin arrangement identification method. Specifications Parts Branch unit (Input) FCN connector type Branch unit (Input) MIL connector type Model FMA-TF4120-MB FMA-TE4120-MB PC A1SX41, AJ35TC1-32D Compatible with 32-input model AX42, A1SX42 Compatible with 64-input model (32-input×2) Rated voltage DC24V Rated current 0.3A/input, 2A/unit AC500V r.m.s. Dielectric strength Tightening torque for the terminal screw 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 AWG Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) Installed MIL connector (20 pins) Mating connector (40 pins) Mating MIL connector (20 pins) LPA1/2〈Made by Nihon Weidmuller〉 FCN-364P040〈Made by Fujitsu〉 FL20A2MS〈Made by Oki Electric Cable〉 FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] Operating temperature range Mass FL40A2MS〈Made by Oki Electric Cable〉Note 85g [3.00oz.] 80g [2.82oz.] Note : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 998 PC WIRING SYSTEM Compatible Mitsubishi Electric PC manufacturer For the circuit diagrams and specifications of branch units for other manufacturers, consult us. ●Branch unit (Output) ●FMA-TF4020-OR ●FCN connector type ●Branch unit (Output) ●FMA-TE4020-OR ●MIL connector type Dimensions Dimensions CN1 10.5 C2 8 7 6 5 RS IN OUT CN1 CN2 CN2 49 5.1 (3.5) 45 CN0 28.3 4.1 45 28.3 CN0 RS 103 16.7 10.5 10.5 C1 103 16.7 10.5 (mm) 4 3 2 1 (mm) 4.1 Branch Unit, DIN Rail Mounting Type For OMRON, Output 49 5.1 (3.5) 50.5 4.5 4.5 50.5 5 5 5 Circuit diagram Circuit diagram CN0 FCN-364P040 [Fujitsu] LPA1/2 [Nihon Weidmuller] + B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 18 19 1A 1B 1C 1D 1E 1F 1E 16 12 20 21 1D 15 1C 14 LPA1/2 [Nihon Weidmuller] + LPA1/2 [Nihon Weidmuller] CN0 FL40A2MS [Oki Electric Cable] + 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1F 18 19 1A 1B 1C 1D 1E Discontinued 11 13 14 15 16 17 22 23 24 25 26 10 28 17 LPA1/2 [Nihon Weidmuller] B1 10 5 1B 13 1A 12 19 11 29 2A 2B 2C 2D 2E 18 2F 27 2E 26 2D 25 12 13 14 15 16 17 20 21 22 23 24 25 26 2F 28 27 10 11 24 2C 23 2B 22 2A 29 21 28 1F 20 17 1E 16 1D 15 1C 14 1B 13 1A 12 19 11 29 + 1F 2A 2B 2C 2D 2E 2F 27 18 2F 27 10 2E 26 2D 25 24 2C 23 2B 22 2A 29 21 28 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 Specifications Parts Branch unit (Output) FCN connector type Branch unit (Output) MIL connector type Model FMA-TF4020-OR FMA-TE4020-OR Compatible PC PC manufacturer OMRON Compatible with 32-output model C200H-OD218, CQM1-OD213 Compatible with 64-output model (32-output×2) C500-OD213, C200H-OD219 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG No.26...14 Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) Installed MIL connector (20 pins) Mating connector (40 pins) Mating MIL connector (20 pins) 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FCN-364P040〈Made by Fujitsu〉 FL20A2MS〈Made by Oki Electric Cable〉 FCN-367J040〈Made by Fujitsu〉 Note FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note FL20A2FO〈Made by Oki Electric Cable〉 or equivalent −25∼80°C [−13∼176°F] Operating temperature range Mass FL40A2MS〈Made by Oki Electric Cable〉Note 85g [3.00oz.] 80g [2.82oz.] : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 999 For the circuit diagrams and specifications of branch units for other manufacturers, consult us. ●Branch unit (Output) ●FMA-TF4020-MB ●FCN connector type ●Branch unit (Output) ●FMA-TE4020-MB ●MIL connector type Dimensions Dimensions CN1 10.5 C2 IN OUT 8 7 6 5 RS CN1 CN2 CN2 49 5.1 (3.5) 45 CN0 28.3 4.1 45 28.3 CN0 RS 103 16.7 10.5 10.5 C1 103 16.7 10.5 (mm) 4 3 2 1 (mm) 4.1 Branch Unit, DIN Rail Mounting Type For Mitsubishi Electric, Output 49 5.1 (3.5) 50.5 4.5 4.5 50.5 5 5 5 Circuit diagram Circuit diagram LPA1/2 [Nihon Weidmuller] + CN0 FCN-364P040 [Fujitsu] ※ A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 B7 B6 B5 B4 B3 B2 B1 20 21 22 23 24 25 26 11 12 1E 16 1D 15 1C 14 + + LPA1/2 [Nihon Weidmuller] CN0 FL40A2MS [Oki Electric Cable] 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 40 38 36 34 32 30 28 26 24 22 18 16 14 12 10 8 6 4 2 20 21 22 23 24 25 26 20 14 15 16 1B 13 1A 12 19 11 29 2A 2B 2C 2D 2E 2F 17 10 19 1A 1B 1C 1D 1E 18 12 13 14 15 16 18 2E 26 2D 25 24 2C 23 2B 22 2A 29 21 28 1F 17 20 1E 16 1D 15 1C 14 1B 13 1A 12 19 11 28 29 19 1A 1B 1C 1D 1E 2A 2B 2C 2D 2E 2F 17 1F 2F 27 10 11 + 27 Discontinued 13 18 1F A2 A1 LPA1/2 [Nihon Weidmuller] 27 28 17 LPA1/2 [Nihon Weidmuller] B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 10 5 18 1F 2F 27 10 26 2E 2D 25 24 2C 23 2B 22 2A 29 21 28 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 FL20A2MS [Oki Electric Cable] CN1 FL20A2MS [Oki Electric Cable] CN2 ※Differs from Mitsubishi Electric’s pin arrangement identification method. Specifications Parts Branch unit (Output) FCN connector type Branch unit (Output) MIL connector type Model FMA-TF4020-MB FMA-TE4020-MB PC Mitsubishi Electric Compatible with 32-output model A1SY41, AJ35TC1-32T Compatible with 64-output model (32-output×2) AY42, A1SY42 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG No.26...14 Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed connector (40 pins) Installed MIL connector (20 pins) Mating connector (40 pins) Mating MIL connector (20 pins) 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FCN-364P040〈Made by Fujitsu〉 FL20A2MS〈Made by Oki Electric Cable〉 FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] Operating temperature range Mass FL40A2MS〈Made by Oki Electric Cable〉Note 85g [3.00oz.] 80g [2.82oz.] Note : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1000 PC WIRING SYSTEM Compatible PC manufacturer 32-input Unit For OMRON, Input For the circuit diagrams and specifications of input units for other manufacturers, consult us. ●32-input unit ●FMA-TM1132-OR ●FCN connector type ●32-input unit ●FMA-TL1132-OR ●MIL connector type Dimensions Dimensions (mm) 178 10.5 10.5 178 10.5 (3.5) 1 - CH IN 4.1 CH (3.7) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 RS- 53.5 55 5.1 10 11 12 13 14 15 + φ 1 CH - CH IN 4.1 + φ 45 28.3 45 28.3 RS- 16.7 (3.5) 16.7 10.5 (mm) (3.7) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 4.5 4.5 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 5 5 5 Circuit diagram LPA1/2 [Nihon Weidmuller] FCN-364P040 [Fujitsu] B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 1 + 2 - 3 + 4 - 5 + 6 - LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] +- 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 15 0 +- Discontinued 7 + 5 Circuit diagram B1 0 53.5 55 5.1 10 11 12 13 14 15 8 - 9 + 10 - 11 + 12 - 13 + 14 - 15 + 0 - 1 + 2 - 3 + 4 - 5 + 6 - 7 + 8 - 9 + 10 - 11 + 12 - 13 + 14 - + - 1 + 2 - 3 + 4 - 5 + 6 - 7 + 8 - 9 + LP2N 5.08/64 [Nihon Weidmuller] 10 - 11 + 12 - 13 + 14 - 15 + 0 - 1 + 2 - 3 + 4 - 5 + 6 - 7 + 8 - 9 + 10 - 11 + 12 - 13 + 14 - 15 + - LP2N 5.08/64 [Nihon Weidmuller] Specifications Parts 32-input unit FCN connector type Model FMA-TM1132-OR Compatible PC 32-input unit MIL connector type FMA-TL1132-OR PC manufacturer OMRON Compatible with 32-input model C200H-ID216, CQM1-ID213 Compatible with 64-input model (32-input×2) C500-ID219, C200H-ID217 Rated voltage DC24V Rated current 0.3A/input, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for input/terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for input/terminal block for power supply) Connecting wire size (terminal block for input/terminal block for power supply) Solid wire〈H05 (07) V-U〉(terminal block for input/terminal block for power supply) Stranded wire〈H05 (07) V-K〉 No.26...12/No.26...14 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for input 7mm [0.276in.] LP2N5.08/64〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass Note 215g [7.58oz.] 210g [7.41oz.] : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1001 32-input Unit For Mitsubishi Electric, Input For the circuit diagrams and specifications of input units for other manufacturers, consult us. ●32-input unit ●FMA-TM1132-MB ●FCN connector type ●32-input unit ●FMA-TL1132-MB ●MIL connector type Dimensions Dimensions (mm) 178 10.5 10.5 (3.5) 4.1 IN OUT (3.7) 0 1 2 3 4 5 6 7 8 9 A B C D E F RS− 53.5 55 5.1 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F CH 0 IN OUT CH 1 4.1 CH 1 45 28.3 CH 0 10.5 (3.5) 16.7 45 28.3 RS− 178 16.7 10.5 (mm) (3.7) 0 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 1 2 3 4 5 6 7 8 9 A B C D E F + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 4.5 4.5 5 53.5 55 5.1 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 5 5 Circuit diagram 5 Circuit diagram FCN-364P040 [Fujitsu] LPA1/2 [Nihon Weidmuller] ※ A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] +- 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 1F 0 +- Discontinued 0 1 + 2 - 3 + 4 - 5 + 6 7 + - 8 - 9 + A B + - C - D + E - F + 10 - 11 + 12 - 13 + 14 - 15 + 16 - 17 + 18 - 19 + 1A - 1B + 1C - 1D + 1E - + - 1 + 2 - 3 + 4 - 5 + 6 - 7 + 8 9 + - A - B + C - D + E - F + 10 - 11 + 12 - 13 + 14 - 15 + 16 - 17 + 18 - 19 + 1A - 1B + 1C - 1D + 1E - 1F + - LP2N 5.08/64 [Nihon Weidmuller] LP2N 5.08/64 [Nihon Weidmuller] ※Differs from Mitsubishi Electric’s pin arrangement identification method. Specifications Parts 32-input unit FCN connector type 32-input unit MIL connector type Model FMA-TM1132-MB FMA-TL1132-MB PC Mitsubishi Electric Compatible with 32-input model A1SX41, AJ35TC1-32D Compatible with 64-input model (32-input×2) AX42, A1SX42 Rated voltage DC24V Rated current 0.3A/input, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for input/terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for input/terminal block for power supply) No.26...12/No.26...14 Connecting wire size (terminal block for input/terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05(07)V-U〉(terminal block for input/terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for input 7mm [0.276in.] LP2N5.08/64〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass 215g [7.58oz.] 210g [7.41oz.] Note : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1002 PC WIRING SYSTEM Compatible PC manufacturer 32-output Unit For OMRON, Output For the circuit diagrams and specifications of output units for other manufacturers, consult us. ●32-output unit ●FMA-TM1032-OR ●FCN connector type ●32-output unit ●FMA-TL1032-OR ●MIL connector type Dimensions Dimensions (mm) 10.5 10.5 178 10.5 (3.5) - CH OUT (3.7) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 RS- 28.3 1 CH 45 + φ 4.1 45 28.3 RS- 16.7 (3.5) + φ 53.5 55 5.1 10 11 12 13 14 15 16.7 178 1 CH - CH OUT 4.1 10.5 (mm) (3.7) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4.5 4.5 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 5 5 5 Circuit diagram LPA1/2 [Nihon Weidmuller] B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 1 + 2 + 3 + 4 + 5 + 6 + +- LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 +- Discontinued 7 + 5 Circuit diagram FCN-364P040 [Fujitsu] 0 53.5 55 5.1 10 11 12 13 14 15 8 + 9 + 10 + 11 + 12 + 13 + 14 + 15 + 0 + 1 + 2 + 3 + 4 + 5 + 6 + 7 + 8 + 9 + 10 + 11 + 12 + 13 + 14 + 3 0 15 + 1 + 5 1 + 7 2 + 9 3 + 11 4 + 13 5 + 15 6 + 17 7 + 19 8 21 9 + + 23 10 + 25 11 + 27 12 + 29 13 + 31 14 + 33 15 + 35 0 + 37 1 + 39 2 + 3 + 4 + 5 + 6 + 7 + 8 + 9 + 10 + 11 + 12 + 13 + 14 + 15 + + LP2N 5.08/64 [Nihon Weidmuller] LP2N 5.08/64 [Nihon Weidmuller] Specifications Parts 32-output unit FCN connector type Model FMA-TM1032-OR Compatible PC 32-output unit MIL connector type FMA-TL1032-OR PC manufacturer OMRON Compatible with 32-output model C200HOD218, CQM1-OD213 Compatible with 64-output model (32-output×2) C500-OD213, C200H-OD219 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for output/terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for output/terminal block for power supply) No.26...12/No.26...14 Connecting wire size (terminal block for output / terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05 (07) V-U〉(terminal block for output / terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for output 7mm [0.276in.] LP2N5.08/64〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass Note 215g [7.58oz.] 210g [7.41oz.] : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1003 32-output Unit For Mitsubishi Electric, Output For the circuit diagrams and specifications of output units for other manufacturers, consult us. ●32-output unit ●FMA-TM1032-MB ●FCN connector type ●32-output unit ●FMA-TL1032-MB ●MIL connector type Dimensions Dimensions (mm) 178 10.5 10.5 178 10.5 (3.5) CH IN OUT 4.1 1 (3.7) 0 1 2 3 4 5 6 7 8 9 A B C D E F RS− 53.5 55 5.1 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F CH 0 IN OUT CH 1 4.1 CH 0 45 28.3 45 28.3 RS− 16.7 (3.5) 16.7 10.5 (mm) (3.7) 0 1 2 3 4 5 6 7 8 9 A B C D E F 53.5 55 5.1 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4.5 4.5 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 5 5 5 Circuit diagram 5 Circuit diagram FCN-364P040 [Fujitsu] A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 LPA1/2 [Nihon Weidmuller] ※ A7 A6 A5 A4 A3 A2 A1 LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] 39 +- 40 1F 0 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 +- Discontinued B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 1 0 + 2 + 3 + 4 + 5 + 6 + 7 + 8 + 9 + A + B8 B + B7 C + B6 D + B5 E + B4 F + B3 10 + B2 11 + B1 12 + 13 + 14 + 15 + 16 + 17 + 18 + 19 + 1A + 1B + 1C + 1D + 1E + + + 38 36 1 + 34 2 + 32 3 + 30 4 + 28 5 + 26 6 + 24 7 + 22 8 20 9 + + 18 A + 16 B + 14 C + 12 D + 10 E + 8 F + 6 10 + 4 11 + 2 12 + 13 + 14 + 15 + 16 + 17 + 18 + 19 + 1A + 1B + 1C + 1D + 1E + 1F + + LP2N 5.08/64 [Nihon Weidmuller] LP2N 5.08/64 [Nihon Weidmuller] ※Differs from Mitsubishi Electric’s pin arrangement identification method. Specifications Parts 32-output unit FCN connector type 32-output unit MIL connector type Model FMA-TM1032-MB FMA-TL1032-MB PC Mitsubishi Electric Compatible with 32-output model A1SY41, AJ35TC1-32T Compatible with 64-output model (32-output×2) AY42, A1SY42 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for output / terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for output / terminal block for power supply) No.26...12/No.26...14 Connecting wire size (terminal block for output / terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05 (07) V-U〉(terminal block for output / terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05(07)V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for output 7mm [0.276in.] LP2N5.08/64〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass 215g [7.58oz.] 210g [7.41oz.] Note : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS.The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1004 PC WIRING SYSTEM Compatible PC manufacturer 8- and 16-input Unit DIN Rail Mounting Type ●8-input unit ●(DIN rail mounting type) ●FMA-TM1108 ●16-input unit ●(DIN rail mounting type) ●FMA-TM1116 Dimensions Dimensions 45 28.3 16.7 1 2 3 4 + L 4.1 RS- C 45 28.3 CN2 7 6 5 4 3 2 1 0 − CN1 10.5 10.5 103 10.5 IN OUT RS- CH CN1 4.1 103 10.5 (mm) 16.7 (mm) CH H (3.7) Jumper 53.5 55 5.1 (3.7) 53.5 55 5.1 + 0 1 2 3 4 5 6 7 8 9 A B C D E F + 0 1 2 3 4 5 6 7 + − + − + − + − + − + − + − + − + − 4.5 4.5 − + − + − + − + − − 5 5 5 Circuit diagram Circuit diagram FL20A2MS [Oki Electric Cable] 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] Discontinued XJ8D-2411/ XJ8A-0211 [OMRON] L 20 19 20 19 18 17 18 17 16 15 16 15 14 13 14 13 12 11 12 11 10 9 10 9 8 7 8 7 6 5 6 5 4 3 4 3 2 1 2 1 ※1 H 0 1 2 3 4 5 6 7 + + 0 1 2 3 4 5 6 7 + ※2 0 – 1 Specifications 2 3 4 5 8-input unit (DIN rail mounting type) FMA-TM1108 C D E F 16-input unit (DIN rail mounting type) 0.3A/input, 2A/unit 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] Solid wire〈H05(07)V-U〉 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) 7mm [0.276in.] LP2N5.08/20〈Made by Nihon Weidmuller〉 LP2N5.08/34〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent Operating temperature range −25∼80°C [−13∼176°F] 105g [3.70oz.] 125g [4.41oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1005 ※2 AC500V r.m.s. Connecting wire size (Terminal block) Mating MIL connector (20 pins) B 0.3A/input, 1A/unit AWG Installed MIL connector (20 pins) A DC24V Dielectric strength Terminal block for input 9 FMA-TM1116 Rated voltage Stranded wire〈H05(07)V-K〉 8 ※1: By switching the jumper(short-circuit socket), freely select either H or L. ※2: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Model Tightening torque for the terminal screw 7 LP2N5.08/34 [Nihon Weidmuller] Parts Rated current 6 + – + – + – + – + – + – + – + – – + – + – + – + – – LP2N5.08/20 [Nihon Weidmuller] Mass 5 8- and 16-input Unit Box-mounting Type ●8-input unit ●(Box-mounting type) ●FMA-TM2108 ●16-input unit ●(Box-mounting type) ●FMA-TM2116 Dimensions Dimensions 2-φ4.6 Burring processed mounting hole 1010 4-M3×0.5 55 5 1.2 Jumper (mm) 2-φ4.6 Burring processed mounting hole 1010 55 6 6 CN2 CH CH (3.7) 59 2 C2 C1 1 65 67.4 CN2 55 C2 (3.7) 59 1 2 0 1 2 3 4 5 6 7 CN1 65 67.4 + 55 C1 − IN OUT − L + H CN1 4-M3×0.5 70 5 1.2 (mm) IN OUT 33.5 (3) 99 40 (2) 41.2 8 158 + 0 1 2 3 4 5 6 7 + + 0 1 2 3 4 5 6 7 8 9 A B C D E F + − + − + − + − + − + − − 4-φ4 161416 14 16 14 16 25 25 161416 14 16 - + - + - + - + - + 55 2-φ8 10 10 70 33.5 (3) 139 40 (2) 41.2 Circuit diagram Circuit diagram 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 + - − 2-φ8 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] Discontinued XJ8D-2411/ XJ8A-0211 [OMRON] L 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 ※1 H 0 1 2 3 4 5 6 7 + + 0 1 2 3 4 5 6 7 + ※2 0 – 1 2 + – Specifications 3 4 + – – + – + – + – + – – LP2N5.08/20 [Nihon Weidmuller] 8-input unit (Box-mounting type) FMA-TM2108 0.3A/input, 1A/unit Mating MIL connector (20 pins) B C + – D E + – F ※2 + + – – 0.3A/input, 2A/unit 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] Exposed wire length (Terminal block) Installed MIL connector (20 pins) A AC500V r.m.s. Solid wire〈H05(07)V-U〉 Terminal block for input 9 + – FMA-TM2116 AWG Stranded wire〈H05(07)V-K〉 8 DC24V Dielectric strength Connecting wire size (Terminal block) 7 + – 16-input unit (Box-mounting type) Rated voltage Tightening torque for the terminal screw 6 LP2N5.08/36 [Nihon Weidmuller] Model Rated current 5 + – ※1: By switching the jumper(short-circuit socket), freely select either H or L. ※2: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts LP2N5.08/20〈Made by Nihon Weidmuller〉 LP2N5.08/36〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent SPCC/Black zinc plated (MFZnD) Materials of box/surface treatment 1.2mm [0.047in.] Plate thickness −25∼80°C [−13∼176°F] Operating temperature range Mass - 6-φ4 ※This drawing is scaled differently from the other drawings. FL20A2MS [Oki Electric Cable] + 55 ※This drawing is scaled differently from the other drawings. FL20A2MS [Oki Electric Cable] - 365g [12.87oz.] 480g [16.93oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1006 PC WIRING SYSTEM 118 25 25 8 8- and 16-output Unit DIN Rail Mounting Type ●8-output unit (DIN rail mounting type) ●FMA-TM1008 ●16-output unit (DIN rail mounting type) ●FMA-TM1016 Dimensions Dimensions 103 103 10.5 OUT RS- CH CN1 4.1 + 1 2 3 4 45 28.3 16.7 RS- 4.1 CN2 C 45 28.3 CN1 7 6 5 4 3 2 1 0 L 10.5 10.5 − 10.5 (mm) 16.7 (mm) CH H (3.7) Jumper 1 + 0 53.5 55 5.1 + 0 1 2 3 4 5 6 7 8 9 A B C D E F 2 3 4 5 6 7 + − + + + + + + + + + + + + + + + + 5 4.5 4.5 − + + + + + + + + − 5 5 Circuit diagram 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 5 Circuit diagram FL20A2MS [Oki Electric Cable] 20 53.5 55 5.1 (3.7) FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] 20 19 20 19 18 17 18 17 16 15 16 15 14 13 14 13 12 11 12 11 10 9 10 9 8 7 8 7 6 5 6 5 4 3 4 3 2 1 2 1 Discontinued XJ8D-2411/ XJ8A-0211 [OMRON] ※1 H L + 0 1 0 2 1 3 2 4 3 5 4 6 5 7 6 7 + ※2 + 0 – 1 2 3 4 5 6 7 8 9 A B C D E F ※2 + + + + + + + + + + + + + + + + – + + + + + + + + – LP2N5.08/34 [Nihon Weidmuller] LP2N5.08/20 [Nihon Weidmuller] Specifications ※1: By switching the jumper (short-circuit socket), freely select either H or L. ※2: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts 8-output unit (DIN rail mounting type) Model FMA-TM1008 FMA-TM1016 Rated voltage Rated current DC24V 0.3A/output, 1A/unit 0.3A/output, 2A/unit AC500V r.m.s. Dielectric strength Tightening torque for the terminal screw 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 AWG 0.13∼4mm2 [0.00020∼0.00620in.2] Connecting wire size (Terminal block) Solid wire〈H05(07)V-U〉 Stranded wire〈H05(07)V-K〉 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] Exposed wire length (Terminal block) Terminal block for output Installed MIL connector (20 pins) Mating MIL connector (20 pins) LP2N5.08/20〈Made by Nihon Weidmuller〉 LP2N5.08/34〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] Operating temperature range Mass 16-output unit (DIN rail mounting type) 105g [3.70oz.] 125g [4.41oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1007 8- and 16-output Unit Box-mounting Type ●8-output unit ●(Box-mounting type) ●FMA-TM2008 ●16-output unit ●(Box-mounting type) ●FMA-TM2016 Dimensions Dimensions 2-φ4.6 Burring processed mounting hole 1010 4-M3×0.5 55 5 1.2 Jumper (mm) 2-φ4.6 Burring processed mounting hole 1010 55 6 6 (3.7) 59 2 C2 C1 1 65 67.4 CN2 CN2 55 C2 (3.7) 59 1 2 0 1 2 3 4 5 6 7 CN1 65 67.4 + 55 C1 − OUT − L + H CN1 4-M3×0.5 70 5 1.2 (mm) CH CH OUT 40 (2) 41.2 8 33.5 (3) 99 158 + 0 1 2 3 4 5 6 7 8 9 A B C D E F + − + + + + + + + + + + + + + + + + − − + + + + + + + + − 4-φ4 55 161416 14 16 14 16 25 25 161416 14 16 2-φ8 10 10 70 55 ※This drawing is scaled differently from the other drawings. Circuit diagram Circuit diagram 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] Discontinued XJ8D-2411/ XJ8A-0211 [OMRON] L 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 ※1 H 0 1 2 3 4 5 6 7 + + 0 1 2 3 4 5 6 7 + ※2 0 – 1 2 3 4 Specifications 8-output unit (Box-mounting type) FMA-TM2008 C D E F ※2 + – 16-output unit (Box-mounting type) 0.3A/output, 2A/unit 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] Exposed wire length (Terminal block) Mating MIL connector (20 pins) B AC500V r.m.s. Solid wire〈H05(07)V-U〉 Installed MIL connector (20 pins) A 0.3A/output, 1A/unit AWG Terminal block for output 9 DC24V Dielectric strength Stranded wire〈H05(07)V-K〉 8 FMA-TM2016 Rated voltage Connecting wire size (Terminal block) 7 ※1: By switching the jumper(short-circuit socket), freely select either H or L. ※2: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Model Tightening torque for the terminal screw 6 LP2N5.08/36 [Nihon Weidmuller] Parts Rated current 5 + + + + + + + + + + + + + + + + – + + + + + + + + – LP2N5.08/20 [Nihon Weidmuller] LP2N5.08/20〈Made by Nihon Weidmuller〉 LP2N5.08/36〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent SPCC/Black zinc plated (MFZnD) Materials of box/surface treatment 1.2mm [0.047in.] Plate thickness −25∼80°C [−13∼176°F] Operating temperature range Mass 2-φ8 6-φ4 ※This drawing is scaled differently from the other drawings. FL20A2MS [Oki Electric Cable] 33.5 (3) 139 40 (2) 41.2 + 0 1 2 3 4 5 6 7 + 365g [12.87oz.] 480g [16.93oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1008 PC WIRING SYSTEM 118 25 25 8 8 LO/HI-only Inputs Unit DIN Rail Mounting Type ●8 LO-only inputs unit (DIN rail mounting type) ●FMA-TJ1108 ●8 HI-only inputs unit (DIN rail mounting type) ●FMA-TK1108 Dimensions Dimensions CN2 RS- CH 1 C CH (3.7) + 0 4.1 CN1 16.7 10.5 1 2 3 4 C + 1 2 3 4 45 28.3 16.7 RS- 103 10.5 4.1 45 28.3 CN2 − CN1 10.5 + 103 10.5 (mm) − (mm) 5.1 53.5 55 (3.7) 2 3 4 5 6 7 + + 8 9 A B C D E F 5 + 4.5 5 5 Circuit diagram 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 5 Circuit diagram FL20A2MS [Oki Electric Cable] 20 53.5 55 − + − + − + − + − − 4.5 − + − + − + − + − − 5.1 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 Discontinued + ※ 0 1 2 3 4 5 6 7 + – + – + – + – + – – + LP2N5.08/20 [Nihon Weidmuller] Specifications ※ 8 9 A B C D E F + – + – + – + – + – – LP2N5.08/20 [Nihon Weidmuller] ※: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts 8 LO-only inputs unit (DIN rail mounting type) 8 HI-only inputs unit (DIN rail mounting type) Model FMA-TJ1108 FMA-TK1108 Rated voltage DC24V Rated current 0.3A/input, 1A/unit Dielectric strength Tightening torque for the terminal screw AWG Connecting wire size (Terminal block) Solid wire〈H05(07)V-U〉 Stranded wire〈H05(07)V-K〉 Exposed wire length (Terminal block) Terminal block for input Installed MIL connector (20 pins) Mating MIL connector (20 pins) Operating temperature range Mass AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] LP2N5.08/20〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] 105g [3.70oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1009 8 LO/HI-only Inputs Unit Box-mounting Type ●8 LO-only inputs unit (Box-mounting type) ●FMA-TJ2108 ●8 HI-only inputs unit (Box-mounting type) ●FMA-TK2108 Dimensions Dimensions 2-φ4.6 Burring processed mounting hole 1010 2-φ4.6 Burring processed mounting hole 1010 4-M3×0.5 70 40 (2) 41.2 CN2 CH 8 33.5 (3) 99 118 + 0 1 2 3 4 5 6 7 + + − + − + − + − + − − 4-φ4 9 A B C Circuit diagram Circuit diagram 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 F + 4-φ4 ※This drawing is scaled differently from the other drawings. 20 E 70 161416 14 16 ※This drawing is scaled differently from the other drawings. FL20A2MS [Oki Electric Cable] D − + − + − + − + − − 10 161416 14 16 8 2-φ8 25 25 10 70 33.5 (3) 99 40 (2) 41.2 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] Discontinued + 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 ※ 0 1 2 3 4 5 6 7 + – + – + – + – + – – + ※ 8 9 A B C D E F + – + – + – + – + – – LP2N5.08/20 [Nihon Weidmuller] LP2N5.08/20 [Nihon Weidmuller] Specifications 2-φ8 25 25 118 IN OUT C2 1 2 65 67.4 55 CN2 CH 8 C1 (3.7) 59 C2 1 2 + CN1 C1 − 65 67.4 + 55 − IN OUT (3.7) 59 6 6 5 1.2 (mm) CN1 4-M3×0.5 70 5 1.2 (mm) ※: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts 8 LO-only inputs unit (Box-mounting type) 8 HI-only inputs unit (Box-mounting type) Model FMA-TJ2108 FMA-TK2108 Rated voltage DC24V Rated current 0.3A/input, 1A/unit Tightening torque for the terminal screw AWG Connecting wire size (Terminal block) Solid wire〈H05(07)V-U〉 Stranded wire〈H05(07)V-K〉 Exposed wire length (Terminal block) Terminal block for input Installed MIL connector (20 pins) Mating MIL connector (20 pins) Materials of box/surface treatment Plate thickness Operating temperature range Mass AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] PC WIRING SYSTEM Dielectric strength LP2N5.08/20〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent SPCC/Black zinc plated (MFZnD) 1.2mm [0.047in.] −25∼80°C [−13∼176°F] 365g [12.87oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1010 8 LO/HI-only Outputs Unit DIN Rail Mounting Type ●8 LO-only outputs unit (DIN rail mounting type) ●FMA-TJ1008 ●8 HI-only outputs unit (DIN rail mounting type) ●FMA-TK1008 Dimensions Dimensions CN2 RS- CH 1 C CH (3.7) + 0 4.1 CN1 16.7 10.5 1 2 3 4 C + 1 2 3 4 45 28.3 16.7 RS- 103 10.5 4.1 45 28.3 CN2 − CN1 10.5 + 103 10.5 (mm) − (mm) 5.1 53.5 55 (3.7) 2 3 4 5 6 7 + + − + + + + + + + + − 8 9 A B C D E F 5.1 + − + + + + + + + + − 4.5 4.5 5 5 5 Circuit diagram 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 5 Circuit diagram FL20A2MS [Oki Electric Cable] 20 53.5 55 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 Discontinued + ※ 0 1 2 3 4 5 6 7 + – + + + + + + + + – + LP2N5.08/20 [Nihon Weidmuller] LP2N5.08/20 [Nihon Weidmuller] Specifications ※ 8 9 A B C D E F + – + + + + + + + + – ※: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts 8 LO-only outputs unit (DIN rail mounting type) 8 HI-only outputs unit (DIN rail mounting type) Model FMA-TJ1008 FMA-TK1008 Rated voltage DC24V Rated current 0.3A/output, 1A/unit Dielectric strength Tightening torque for the terminal screw AWG Connecting wire size (Terminal block) Solid wire〈H05(07)V-U〉 Stranded wire〈H05(07)V-K〉 Exposed wire length (Terminal block) Terminal block for output Installed MIL connector (20 pins) Mating MIL connector (20 pins) Operating temperature range Mass AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] LP2N5.08/20〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] 105g [3.70oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1011 8 LO/HI-only Outputs Unit Box-mounting Type ●8 LO-only outputs unit ●(Box-mounting type) ●FMA-TJ2008 ●8 HI-only outputs unit ●(Box-mounting type) ●FMA-TK2008 Dimensions Dimensions (mm) 2-φ4.6 Burring processed mounting hole 1010 2-φ4.6 Burring processed mounting hole 1010 4-M3×0.5 70 5 1.2 40 (2) 41.2 118 + 8 9 A B C 10 161416 14 16 Circuit diagram Circuit diagram 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 F + 4-φ4 ※This drawing is scaled differently from the other drawings. 20 E 70 2-φ8 ※This drawing is scaled differently from the other drawings. FL20A2MS [Oki Electric Cable] D − + + + + + + + + − 25 25 10 70 4-φ4 33.5 (3) 99 40 (2) 41.2 + 0 1 2 3 4 5 6 7 + − + + + + + + + + − 161416 14 16 C2 1 2 CN2 CN1 65 67.4 55 CN2 8 33.5 (3) 99 FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] FL20A2MS [Oki Electric Cable] Discontinued + 20 19 20 19 20 19 18 17 18 17 18 17 16 15 16 15 16 15 14 13 14 13 14 13 12 11 12 11 12 11 10 9 10 9 10 9 8 7 8 7 8 7 6 5 6 5 6 5 4 3 4 3 4 3 2 1 2 1 2 1 ※ 0 1 2 3 4 5 6 7 + – + + + + + + + + – + LP2N5.08/20 [Nihon Weidmuller] Specifications 2-φ8 25 25 118 OUT CH CH 8 C1 (3.7) 59 C2 1 2 + CN1 C1 − 65 67.4 + 55 − OUT (3.7) 59 6 6 4-M3×0.5 70 5 1.2 (mm) ※ 8 9 A B C D E F + – + + + + + + + + – LP2N5.08/20 [Nihon Weidmuller] ※: Terminal block (signal wires) No. indication marker: Included in the product and select any from 0…16, A…F. Parts 8 LO-only outputs unit (Box-mounting type) 8 HI-only outputs unit (Box-mounting type) Model FMA-TJ2008 FMA-TK2008 Rated voltage DC24V Rated current 0.3A/output, 1A/unit Tightening torque for the terminal screw AWG Connecting wire size (Terminal block) Solid wire〈H05(07)V-U〉 Stranded wire〈H05(07)V-K〉 Exposed wire length (Terminal block) Terminal block for output Installed MIL connector (20 pins) Mating MIL connector (20 pins) Materials of box/surface treatment Plate thickness Operating temperature range Mass AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf] No.26...12 0.13∼4mm2 [0.00020∼0.00620in.2] 0.5∼4mm2 [0.00078∼0.00620in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] PC WIRING SYSTEM Dielectric strength LP2N5.08/20〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉 or equivalent SPCC/Black zinc plated (MFZnD) 1.2mm [0.047in.] −25∼80°C [−13∼176°F] 365g [12.87oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1012 Connector Type 8-input Unit DIN Rail Mounting Type ●Connector type 8-input unit〔main unit〕 ●(DIN rail mounting type) ●FMA-TC1108 ●Connector type 8-input unit〔sub-unit〕 ●(DIN rail mounting type) ●FMA-TD1108 Dimensions Dimensions RS CN-PS1 CN-0 +S− CN-1 CN-2 CN-3 CN-4 CN-5 CN-6 CN-PS2 CN-7 IN CN-PC1 RS H L CN-PS CN-0(8) CN-1(9) CN-2(A) CN-3(B) CN-4(C) CN-5(D) CN-6(E) CN-7(F) 45 1 2 3 28.3 16.7 CN-PC2 4.1 28.3 IN CN-PC1 10.5 69 16.7 10.5 10.5 103 45 10.5 (mm) 4.1 (mm) 1 2 3 +S− 49 5.1 49 5.1 50.5 4.5 4.5 50.5 5 5 5 Circuit diagram Circuit diagram Discontinued CN-PC 1 ▼ 19 17 15 13 11 LPA1/2 [Nihon Weidmuller] 5 ▼ 9 7 5 3 1 19 17 15 13 11 9 7 5 3 1 20 18 16 14 12 10 8 6 4 2 20 18 16 14 12 10 8 6 4 2 + CN-PC 1 CN-PC 2 19 17 15 13 11 FL20A2MS [Oki Electric Cable] ▼ 9 7 5 3 1 20 18 16 14 12 10 8 6 4 2 FL20A2MS [Oki Electric Cable] LPA1/2 [Nihon Weidmuller] + + − CN-PS 1 − − CN-PS CN-PS 2 1 2 3 1 2 3 + S − CN-0 CN-1 CN-2 CN-3 CN-4 CN-5 CN-6 ※Jumper (short circuit socket) cannot be switched. CN-7 + S − CN-0(8) CN-1(9) CN-2(A) CN-3(B) CN-4(C) CN-5(D) CN-6(E) CN-7(F) Wafer 53375-0310 [Molex Japan] Wafer 53375-0310 [Molex Japan] Specifications Parts Connector type 8-input unit (main unit) Model FMA-TC1108 Connector type 8-input unit (sub-unit) FMA-TD1108 Rated voltage DC24V Rated current 0.3A/input, 1A/unit Dielectric strength Tightening torque for the terminal screw AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG Connecting wire size (Terminal block) No.26...14 0.13∼2.5mm2 [0.00020∼0.00388in.2] Power supply Solid wire〈H05 (07) V-U〉 terminal 0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05 (07) V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed MIL connector (20 pins) Mating MIL connector (20 pins) Installed wafer (3 pins) Mating housing (3 pins) Mating terminal 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent 53375-0310〈Made by Molex Japan〉 51103-0300〈Made by Molex Japan〉 50351-8100〈Made by Molex Japan〉 ● Applicable wire Lead wire size: AWG No.28...22 Insulation outer diameter:φ1.15∼φ1.8mm [φ0.0453∼φ0.071in.] Exposed wire length: 2.3∼2.8mm [0.091∼0.110in.] −25∼80°C [−13∼176°F] Operating temperature range Mass 75g [2.65oz.] 55g [1.94oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 3. For details of applicable mating housings and terminals, see p.994. 1013 Connector Type 16-input Unit DIN Rail Mounting Type ●Connector type 16-input unit (DIN rail mounting type) ●FMA-TC1116 Dimensions (mm) 10.5 28.3 CN-PS IN CN-1 CN-2 CN-3 CN-4 CN-5 RS CN-6 CN-7 4.1 CN-PC CN-0 1 2 3 +S− CN-8 CN-9 CN-A CN-B CN-C CN-D 45 103 16.7 10.5 CN-E CN-F 49 5.1 4.5 50.5 5 5 Circuit diagram LPA1/2 [Nihon Weidmuller] Discontinued CN-PC + 19 17 15 13 11 − CN-PS 9 7 5 3 20`` 18 16 14 12 10 8 6 4 ▼ 1 2 FL20A2MS [Oki Electric Cable] 1 2 3 + S − CN-0 CN-1 CN-8 CN-2 CN-9 CN-3 CN-A CN-4 CN-B CN-5 CN-C CN-6 CN-D CN-7 CN-E CN-F Wafer 53375-0310 [Molex Japan] Specifications Parts Connector type 16-input unit Model FMA-TC1116 Rated voltage DC24V Rated current 0.3A/input, 2A/unit Tightening torque for the terminal screw AWG Connecting wire size (Terminal block) Power supply Solid wire〈H05 (07) V-U〉 terminal Stranded wire〈H05 (07) V-K〉 Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed MIL connector (20 pins) Mating MIL connector (20 pins) Installed wafer (3 pins) Mating housing (3 pins) Mating terminal Operating temperature range Mass AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 0.13∼2.5mm2 [0.00020∼0.00388in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent 53375-0310〈Made by Molex Japan〉 51103-0300〈Made by Molex Japan〉 50351-8100〈Made by Molex Japan〉 ● Applicable wire Lead wire size: AWG No.28...22 Insulation outer diameter:φ1.15∼φ1.8mm [φ0.0453∼φ0.071in.] Exposed wire length: 2.3∼2.8mm [0.091∼0.110in.] −25∼80°C [−13∼176°F] 70g [2.47oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-ID218CN, C200H-ID215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 3. For details of applicable mating housings and terminals, see p.994. 1014 PC WIRING SYSTEM Dielectric strength Connector Type 8-output Unit DIN Rail Mounting Type ●Connector type 8-output unit〔main unit〕 ●(DIN rail mounting type) ●FMA-TC1008 ●Connector type 8-output unit〔sub-unit〕 ●(DIN rail mounting type) ●FMA-TD1008 Dimensions Dimensions +S− CN-1 CN-2 CN-3 CN-4 CN-5 CN-6 CN-PS2 CN-7 CN-PC1 OUT RS H L 16.7 10.5 69 CN-PS CN-0(8) CN-1(9) CN-2(A) CN-3(B) CN-4(C) CN-5(D) CN-6(E) CN-7(F) 45 RS CN-PS1 CN-0 45 CN-PC2 1 2 3 28.3 16.7 28.3 OUT CN-PC1 10.5 10.5 103 4.1 10.5 (mm) 4.1 (mm) 1 2 3 +S− 49 5.1 49 5.1 50.5 4.5 4.5 50.5 5 5 5 Circuit diagram CN-PC 1 Circuit diagram Discontinued ▼ 19 17 15 13 11 LPA1/2 [Nihon Weidmuller] 9 20 18 16 14 12 10 + 5 ▼ 7 5 3 1 19 17 15 13 11 9 7 5 3 1 8 6 4 2 20 18 16 14 12 10 8 6 4 2 CN-PC 1 CN-PC 2 FL20A2MS [Oki Electric Cable] 19 17 15 13 11 ▼ 9 7 5 3 1 20 18 16 14 12 10 8 6 4 2 FL20A2MS [Oki Electric Cable] LPA1/2 [Nihon Weidmuller] + + − CN-PS 1 − − CN-PS 2 CN-PS 1 2 3 1 2 3 + S − CN-0 CN-1 CN-2 CN-3 CN-4 CN-5 CN-6 ※Jumper (short circuit socket) cannot be switched. CN-7 + S − CN-0(8) CN-1(9) CN-2(A) CN-3(B) CN-4(C) CN-5(D) CN-6(E) CN-7(F) Wafer 53375-0310 [Molex Japan] Wafer 53375-0310 [Molex Japan] Specifications Parts Connector type 8-output unit (main unit) Model FMA-TC1008 Connector type 8-output unit (sub-unit) FMA-TD1008 Rated voltage DC24V Rated current 0.3A/output, 1A/unit Dielectric strength Tightening torque for the terminal screw AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG No.26...14 Power Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] supply Solid wire〈H05 (07) V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] terminal Stranded wire〈H05 (07) V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed MIL connector (20 pins) Mating MIL connector (20 pins) Installed wafer (3 pins) Mating housing (3 pins) Mating terminal 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent 53375-0310〈Made by Molex Japan〉 51103-0300〈Made by Molex Japan〉 50351-8100〈Made by Molex Japan〉 ● Applicable wire Core wire size: AWG No.28...22 Insulation outer diameter:φ1.15∼φ1.8mm [φ0.0453∼φ0.071in.] Exposed wire length: 2.3∼2.8mm [0.091∼0.110in.] Operating temperature range Mass −25∼80°C [−13∼176°F] 75g [2.65oz.] 55g [1.94oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 3. For details of applicable mating housings and terminals, see p.994. 1015 Connector Type 16-output Unit DIN Rail Mounting Type ●Connector type 16-output unit (DIN rail mounting type) ●FMA-TC1016 (mm) 10.5 103 28.3 CN-PS OUT CN-1 CN-2 CN-3 CN-4 CN-5 RS CN-6 CN-7 4.1 CN-PC CN-0 1 2 3 +S− CN-8 CN-9 CN-A CN-B CN-C CN-D 45 10.5 16.7 Dimensions CN-E CN-F 49 5.1 4.5 50.5 5 5 Circuit diagram LPA1/2 [Nihon Weidmuller] Discontinued CN-PC + 19 17 15 13 11 − CN-PS 9 7 5 3 20`` 18 16 14 12 10 8 6 4 ▼ 1 2 FL20A2MS [Oki Electric Cable] 1 2 3 + S − CN-0 CN-1 CN-8 CN-2 CN-9 CN-3 CN-A CN-4 CN-B CN-5 CN-C CN-6 CN-D CN-7 CN-E CN-F Wafer 53375-0310 [Molex Japan] Specifications Parts Connector type 16-output unit Model FMA-TC1016 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Tightening torque for the terminal screw AWG AC500V r.m.s. 0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...14 Power Connecting wire size (Terminal block) 0.13∼2.5mm2 [0.00020∼0.00388in.2] supply Solid wire〈H05 (07) V-U〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] terminal Stranded wire〈H05 (07) V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Installed terminal block (For power supply) Installed MIL connector (20 pins) Mating MIL connector (20 pins) Installed wafer (3 pins) Mating housing (3 pins) Mating terminal Operating temperature range Mass 7mm [0.276in.] LPA1/2〈Made by Nihon Weidmuller〉 FL20A2MS〈Made by Oki Electric Cable〉 FL20A2FO〈Made by Oki Electric Cable〉or equivalent 53375-0310〈Made by Molex Japan〉 51103-0300〈Made by Molex Japan〉 50351-8100〈Made by Molex Japan〉 ● Applicable wire Lead wire size: AWG No.28...22 Insulation outer diameter:φ1.15∼φ1.8mm [φ0.0453∼φ0.071in.] Exposed wire length: 2.3∼2.8mm [0.091∼0.110in.] −25∼80°C [−13∼176°F] 70g [2.47oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 3. For details of applicable mating housings and terminals, see p.994. 1016 PC WIRING SYSTEM Dielectric strength 32-output Common Reduction Unit For OMRON, Output For the circuit diagrams and specifications of output units for other manufacturers, consult us. ●32-output common reduction unit ●FMA-TH1032-OR ●FCN connector type ●32-output common reduction unit ●FMA-TG1032-OR ●MIL connector type Dimensions Dimensions (mm) 10.5 103 10.5 10.5 103 CH 1 O M F K + OUT − RS- 4.1 − RS- 45 28.3 + OUT 4.1 45 28.3 O M F K (3.6) 16.7 (3.6) 16.7 10.5 (mm) CH 1 CH CH (3.7) 113 0 − 1 2 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 + 10 11 12 13 14 15 9 0 − 10 11 12 13 14 15 1 0 2 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 5 10 11 12 13 14 15 9 10 11 12 13 14 15 5 5 Circuit diagram + B2 B3 B4 B5 B6 B7 A1 A2 A3 A4 A5 A6 A7 0 – 1 0 2 1 3 2 4 3 5 4 LPA1/2 [Nihon Weidmuller] LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Discontinued 6 5 5 Circuit diagram FCN-364P040 [Fujitsu] B1 53.5 55 5.1 4.5 0 (3.7) 113 4.5 + 53.5 55 5.1 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 – + 15 14 + 15 0 – 1 0 2 1 3 2 4 3 5 6 4 5 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 + – 15 14 15 LP2N 5.08/34 [Nihon Weidmuller] LP2N 5.08/34 [Nihon Weidmuller] Specifications Parts 32-output common reduction unit FCN connector type 32-output common reduction unit MIL connector type Model FMA-TH1032-OR FMA-TG1032-OR Compatible PC PC manufacturer OMRON Compatible with 32-output model C200HOD218, CQM1-OD213 Compatible with 64-output model (32-output×2) C500-OD213, C200H-OD219 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for output / terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for output / terminal block for power supply) No.26...12/No.26...14 Connecting wire size (terminal block for output / terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05 (07) V-U〉(terminal block for output / terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05 (07) V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for output 7mm [0.276in.] LP2N5.08/34〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass Note 135g [4.76oz.] 130g [4.59oz.] : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1017 32-output Common Reduction Unit For Mitsubishi Electric, Output For the circuit diagrams and specifications of output units for other manufacturers, consult us. ●32-output common reduction unit ●FMA-TH1032-MB ●FCN connector type ●32-output common reduction unit ●FMA-TG1032-MB ●MIL connector type Dimensions Dimensions (mm) 10.5 10.5 + OUT − RS- CH 1 O M F K 45 28.3 16.7 (3.6) 4.1 45 28.3 O M F K 10.5 103 (3.6) 16.7 103 + OUT − RS- 4.1 10.5 (mm) CH 1 CH CH (3.7) 113 0 + 1 2 3 4 5 6 7 8 9 A B C D E 53.5 55 5.1 (3.7) 113 F + − 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 0 1 2 3 4 5 6 7 8 9 A B C D E F 5 4.5 4.5 − 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 5 5 Circuit diagram + A19 A18 A17 A16 A15 A14 B20 B19 B18 B17 B16 B15 B14 0 – 1 10 2 11 3 12 4 13 5 14 LPA1/2 [Nihon Weidmuller] ※ A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 LPA1/2 [Nihon Weidmuller] FL40A2MS [Oki Electric Cable] 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 Discontinued 6 15 5 Circuit diagram FCN-364P040 [Fujitsu] A20 53.5 55 5.1 7 16 8 17 9 18 A 19 B 1A C 1B D 1C E 1D + – + F 1E 0 – 1F 1 10 2 11 LP2N 5.08/34 [Nihon Weidmuller] 3 12 4 13 5 14 6 15 7 16 8 17 9 18 A 19 B 1A C 1B D 1C E 1D + – F 1E 1F LP2N 5.08/34 [Nihon Weidmuller] ※Differs from Mitsubishi Electric’s pin arrangement identification method. Specifications Parts 32-output common reduction unit FCN connector type 32-output common reduction unit MIL connector type Model FMA-TH1032-MB FMA-TG1032-MB PC Mitsubishi Electric Compatible with 32-output model A1SY41, AJ35TC1-32T Compatible with 64-output model (32-output×2) AY42, A1SY42 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for output / terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] AWG (terminal block for output / terminal block for power supply) No.26...12/No.26...14 Connecting wire size (terminal block for output / terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05 (07) V-U〉(terminal block for output / terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05 (07) V-K〉 0.5∼2.5mm2 [0.00078∼0.00388in.2] Exposed wire length (Terminal block) Terminal block for output 7mm [0.276in.] LP2N5.08/34〈Made by Nihon Weidmuller〉 Installed connector (40 pins) FCN-364P040〈Made by Fujitsu〉 FL40A2MS〈Made by Oki Electric Cable〉Note Mating connector (40 pins) FCN-367J040〈Made by Fujitsu〉 FL40A2FO〈Made by Oki Electric Cable〉or equivalent Note Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 −25∼55°C [−13∼131°F] Operating temperature range Mass 135g [4.76oz.] 130g [4.59oz.] Note : For the compatible model of -KY: KEYENCE, the installed connector (34 pins) is Oki Electric Cable’s FL34A2MS. The mating connector should be FL34A2FO (made by Oki Electric Cable) or equivalent. Remark : Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 1018 PC WIRING SYSTEM Compatible PC manufacturer 16-output Common Reduction Unit DIN Rail Mounting Type ●16-output common reduction unit (DIN rail mounting type) ●FMA-TH1016 Dimensions (mm) 10.5 69 10.5 16.7 + − RS− OUT 4.1 28.3 45 (3.6) L H CH + 0 1 8 2 9 3 A 55 4 B 5 C 6 D 7 E F 4.5 − 53.5 5.1 (3.7) 79 5 5 Circuit diagram LPA1/2 [Nihon Weidmuller] FL20A2MS [Oki Electric Cable] + 19 17 15 20 18 16 0 - 1 8 Discontinued 2 9 13 11 9 7 5 3 1 14 12 10 8 6 4 2 3 A 4 B 5 C 6 D + - 7 E F LP2N 5.08/18 [Nihon Weidmuller] Specifications Parts 16-output common reduction unit (DIN rail mounting type) Model FMA-TH1016 Rated voltage DC24V Rated current 0.3A/output, 2A/unit Dielectric strength Tightening torque for the terminal screw (terminal block for output / terminal block for power supply) AWG (terminal block for output / terminal block for power supply) AC500V r.m.s. 0.5∼0.6N・m {0.05∼0.06kgf・m} [4.4∼5.3in・lbf]/0.4∼0.6N・m {0.04∼0.06kgf・m} [3.5∼5.3in・lbf] No.26...12/No.26...14 Connecting wire size (terminal block for output / terminal block for power supply) 0.13∼4mm2 [0.00020∼0.00620in.2]/0.13∼2.5mm2 [0.00020∼0.00388in.2] Solid wire〈H05 (07) V-U〉(terminal block for output / terminal block for power supply) 0.5∼4mm2 [0.00078∼0.00620in.2]/0.5∼2.5mm2 [0.00078∼0.00388in.2] Stranded wire〈H05 (07) V-K〉 Exposed wire length (Terminal block) Terminal block for output 0.5∼2.5mm2 [0.00078∼0.00388in.2] 7mm [0.276in.] LP2N5.08/18〈Made by Nihon Weidmuller〉 Terminal block for power supply LPA1/2〈Made by Nihon Weidmuller〉 Installed MIL connector (20 pins) FL20A2MS〈Made by Oki Electric Cable〉 Mating MIL connector (20 pins) Operating temperature range Mass FL20A2FO〈Made by Oki Electric Cable〉or equivalent −25∼80°C [−13∼176°F] 80g [2.82oz.] Remarks: 1. Rating is for the unit alone. When other connection units exist, their ratings must also be taken into consideration. 2. Can be connected to OMRON’s C500-OD415CN, C200H-OD215, C500-MD211CN, and C200H-MD215. For details, see p.1032. 1019 About Circuit Diagrams and Specifications This catalog does not contain the circuit diagrams, specifications, etc. for all compatible models. For the circuit diagrams, specifications, etc. of units not listed in this catalog, consult us. For details of compatible models, confirm the order codes on p.1025∼1026. PC WIRING SYSTEM Discontinued 1020 PC Wiring System Okiflex Cable Okiflex Cable Achieves Aesthetically Pleasing Wiring Between Units ●Okiflex cable is a remarkable cable that integrates a flat cable and power lines into a sheath for easy crimping connections. In addition, it eliminates the need for separate wiring for power lines. ●While cables with built-in harnesses for PC connectors had set standard lengths, Okiflex cable lets customers crimp connectors, resolving problems like wire length, delivery issues, increasing costs, etc. ●For the heat-shrink tube and various other tools, see p.1026 and 1027. Crimping allowed here Note: Okiflex cable is for fixed wiring. For use in moving applications, consult us. Power cable (Brown, blue) ●Detailed diagram of the flat cable portion Portion which can be crimped (Adhesive portion) Loose wiring portion (Non-adhesive portion) Discontinued Non-adhesive portion (Loose wiring portion) Adhesive portion L1 L1=30mm [1.18in.] L2=100mm [3.94in.] L2 ●Flat cable sectional view ●Sectional view of Okiflex PVC sheath Power line Note AWG24 (For 10 leads) AWG20 (For 20, 40 leads) Brown T A Y P D Blue E Flat cable AWG28 Note: Power line colors have been changed, from red to brown, and from black to blue. mm [in.] Item Model FMA-CX10×□ Flat cable Conductive construction: 7 leads/0.127mm [0.0050in.] (AWG 28) 10 leads Power cable Insulation outer diameter (standard) FMA-CX20×□ FMA-CX40×□ Conductive construction: 11 leads/0.16mm [0.0063in.] (AWG24) 7.3mm [0.287in.] 20 leads 40 leads Conductive construction: 21 leads/0.18mm [0.0071in.] (AWG 20) Number of leads 10 20 Over 0.18 [0.0071] 40 D E 11.43±0.28 [0.4500±0.0110] 12.70±0.38 [0.5000±0.0150] 24.13±0.28 [0.9500±0.0110] 25.40±0.38 [1.0000±0.0150] 49.53±0.38 [1.9500±0.0150] 50.80±0.51 [2.0000±0.0201] mm [in.] 10.6mm [0.417in.] 12.3mm [0.484in.] Number of leads P T Y 10 1.27 [0.0500] (standard) 0.98±0.07 [0.0386±0.0028] Over 0.16 [0.0063] 20 40 1021 A PC Wiring System Crimping Tool ●Crimping tool FMA-HT151 Specifications Features ● Crimping tools can handle all crimping connectors used in PC wiring systems. ● Combinations of dies enables the Fujitsu 360 type, the IDEC Izumi JM series, and the Oki Electric Cable FL series connectors crimping by a single tool. ● MIL standard conforming connectors can also be crimped. ● Because this tool is compact and lightweight, you can use it without becoming fatigued. Made by Fujitsu 360 type (FCN-367J0□□) Applicable Made by IDEC Izumi JM series (JM1S-□□□3) connector Oki Electric Cable FL series (FL-□□A2□O) Other connectors of MIL standard conformity Connector length Max. 83mm [3.27in.] Body length 220mm [8.66in.] Mass 520g [18.34oz.] Main body Materials Die Instructions for Use Grip ● Use the hexagon wrench supplied with the body to change the die direction so that the die combination number for the connector to be crimped comes to the front side. ● When the crimping force is insufficient, fit supplied spacer shims into the grooves at the top and bottom of the die. Dimensions Steel/black Aluminum/black anodized Polypropylene/orange Size of die mounting screw M3 hexagon socket head bolt Applicable hexagon wrench Nominal size 2.5 Discontinued (mm) ● Combination for IDEC Izumi JM series (Die numbers 2 and 3) Spacer shim Die number IZUMI 2 IZUMI・OKI 17.45 IZUMI FUJITSU・IZUMI 3 Die 9.5 ● Combination for Fujitsu 360-type connector(Die numbers 1 and 3) 83 20 1 FUJITSU・IZUMI Supplied hexagon wrench 3 ● Combination for MIL standard conforming products (Die numbers 1 and 4) Connector crimping height: 10.5mm [0.413in.] MIL FUJITSU・MIL Cautions: 1. The connector crimping height can vary somewhat in each connector. Check the dimensions carefully before use. 2. Ensure that the flat cable wiring is securely conforming to the connector cover’s grooves, and then crimp them. 1 10.5 MIL 220 PC WIRING SYSTEM FUJITSU FUJITSU・MIL 16.5 FUJITSU OKI・MIL 4 Cover Flat cable OKI OKI IZUMI・OKI OKI・MIL 2 11.15 ● Combination for Oki Electric Cable FL series (Die numbers 2 and 4) 4 Insert one spacer shim 1022 PC Wiring System Check Unit The check unit eases the functional check for all units and sensors. Using this unit during system maintenance, or software and hardware debugging can shorten working time and improve system’s accuracy. Functions ● Forced ON/OFF for loads or sensors. ● By connecting it to an oscilloscope or high coder, etc., the measurement of timing between sensors, timing between loads, and the monitoring and recording of waveforms become possible. ● Voltage measurement of loads, sensors, etc. ● To check system operating conditions. ● Simultaneous use of 2 check units enables measurement of timing between sensors and loads, or waveform monitoring. Dimensions ●Check unit ●FMA-RCU16F Circuit Diagrams (mm) 2 1 + 4 3 6 5 130 (149) − CN2 FL20A2MA [Oki Electric Cable] CN1 FL20A2MA [Oki Electric Cable] CN3 LPA1/2 [Nihon Weidmuller] 8 7 10 9 12 11 14 13 16 15 18 17 20 19 2 1 4 3 6 5 8 7 10 12 14 9 11 13 Discontinued LF L7 LE L6 LD L5 LC L4 LB L3 LA L2 L9 L1 L8 L0 TP+ CN4 LPA1/2 [Nihon Weidmuller] 16 18 15 17 20 19 + − RF R7 RE R6 RD R5 RC R4 RB R3 RA R2 R9 R1 R8 R0 TP+ TP- TP- 22.5 (41) (ON) N (Normal) 116 OFF Single pole triple throw switch LED 0 LED 1 L0 R0 TP 0 SW 0 L1 TP 1 LED 8 R8 SW 8 SW 1 L9 TP 9 LED 5 L2 R2 L5 SW 2 TP 2 LED 9 L8 TP 8 LED 2 R1 TP 5 LED 10 R9 RA TP 10 LED 6 L6 SW 5 RD TP 13 SW 6 L7 LE SW 13 SW 7 LED 15 RE TP 14 R7 TP 7 LED 14 LD SW 10 LED 7 R6 TP 6 LED 13 LA SW 9 R5 SW 14 LF TP 15 RF SW 15 Major Parts and Instructions qPC-side cable connector wSensor/load-side cable connector eCommon terminal (+) for check rCommon terminal (−) for check q w Use as common terminals for measurement (monitoring) between each address (1bit unit) check terminals i-e and i-r. tPower supply terminal block Connects the power supply lines in the Okiflex cable on the PC side or sensor/load side. ※Check unit: Also used as a power supply for a monitor LED. yMonitor LED The monitor LED is connected to the PC-side connector, and is used for confirmation of operating conditions. uSwitch OFF N (normal) (ON) Forcibly turns OFF the circuits of the connected sensors and loads 1 bit at a time between the q and w connectors (Opens the circuits). Shorts the circuits 1 bit at a time between the q and w connectors. Use this position when leaving equipment in normal operation without performing forced ON/OFF. When the switch is set in this position, the circuit for this bit only is forcibly connected to the GND, and forcibly turned ON, regardless of the operating condition of the sensor and the load connected to the w connector. iCheck terminal One check terminal is provided for each bit. Between the check terminal of the bit to be measured and the e / r common terminals, the voltage and the waveforms of each bit can be obtained. 1023 e r t t y u 0 1 2 3 4 5 6 7 OFF OFF OFF OFF OFF OFF OFF OFF N N N N N N N 8 9 10 OFF OFF N 11 OFF N 12 OFF N 13 14 OFF OFF N N 15 OFF N OFF N i Check Unit Application Example ●When used to connect with a circuit The check unit can be connected between a PC and a manifold, making the following operations possible: ● Send a PC signal to the manifold valve ● Forcibly turn a valve ON ● Forcibly turn a valve OFF Even if the PC programs, etc. are at an incomplete stage, sensor switches’ minor adjustment, etc. can easily be done by manual override operation of valves, etc. ※While the valve is categorized as an output, the same goes for inputs (sensor switches, etc.). A B A B A B A B A B A B A B PC side Manifold solenoid valves Power cable Wiring specification : -F201 (Positive common specification) With a check terminal, you can: ●Measure the applied voltage on a valve ●Measure the time between 2 valves Discontinued ※While the above illustration shows a high coder being used, monitoring can also be performed with testers or oscilloscopes. Caution: For details about the check unit’s connectable locations, see the connection map on p.1033 and 1034. ●When used as a stand-alone Even if the PC programs, etc. are at an incomplete stage, sensor switches’ fine adjustment etc. can easily be done by manual override operation of valves, etc. A B A B A B A B A B A B A B Manifold solenoid valves Power cable Wiring specification : -F201 (Positive common specification) + − PC WIRING SYSTEM DC24V Power supply 1024 Order Codes ●Branch unit Compatible types Input OMRON Direct connecting type Output Mitsubishi Electric Direct connecting type OMRON Mitsubishi Electric YOKOGAWA ELECTRIC KOYO ELECTRONIC INDUSTRIES Hitachi 1 FMA-TF3120-MBA 1 FMA-TF3120-MBB FMA-TF3020-MBA 1 FMA-TF3020-MBB Input C200H-ID216, CQM1-ID213, C500-ID219, C200H-ID217 FMA-TF4120-OR FMA-TE4120-OR 1 Output C200H-OD218, CQM1-OD213, C500-OD213, C200H-OD219 FMA-TF4020-OR FMA-TE4020-OR 1 Input A1SX41, AJ35TC1-32D, AX42, A1SX42 FMA-TF4120-MB FMA-TE4120-MB 1 Output A1SY41, AJ35TC1-32T, AY42, A1SY42 FMA-TF4020-MB FMA-TE4020-MB 1 FMA-TF4120-FJ FMA-TE4120-FJ 1 FMA-TF4020-FJ FMA-TE4020-FJ 1 DI335, DI-6241 FMA-TF4120-TB FMA-TE4120-TB 1 DO335, DO-6242 FMA-TF4020-TB FMA-TE4020-TB 1 Input JAMSC-B2605 FMA-TF4120-YS FMA-TE4120-YS 1 Output JAMSC-B2604 FMA-TF4020-YS FMA-TE4020-YS 1 Input JW-34NC, JW-234N, JW-64NC, JW-264N FMA-TF4120-SP FMA-TE4120-SP 1 Output JW-32SC, JW-232S, JW-62SC, JW-262S FMA-TF4020-SP FMA-TE4020-SP 1 Input F3XD32-3N, F3XD64-3N FMA-TF4120-YG FMA-TE4120-YG 1 Output F3YD32-1A, F3YD64-1A FMA-TF4020-YG FMA-TE4020-YG 1 Input U-09N FMA-TF4120-KD FMA-TE4120-KD 1 Output U-19T FMA-TF4020-KD FMA-TE4020-KD 1 XDC24D2H FMA-TE4120-HT 1 YTR24DH FMA-TE4020-HT 1 AFP23067, AFP33027, AFP33028, AFP33068 FMA-TE4120-MS 1 AFP23407, AFP33487 FMA-TE4020-MS 1 Input KZ-C32X FMA-TE4120-KY 1 Output KZ-C32T FMA-TE4020-KY 1 Input FTU125A, NS-X64-I, NV1X3204(-W), NV1X3206 NC1X3204, NC1X3206, NC1X6404, NC1X6406 FTU222A, NS-Y64-TI, NV1Y32T05P1 NC1Y32T05P1, NC1Y64T05P1-1 Discontinued Matsushita Electric Works KEYENCE 1 FMA-TF3020-OR A1SY41, AY42, A1SY42 Note Input SHARP FMA-TF3120-OR Output Output YASKAWA ELECTRIC Package unit C200H-OD218, C500-OD213, C200H-OD219 A1SX41, AX42, A1SX42 Note Output TOSHIBA MIL connector type C200H-ID216, C500-ID219, C200H-ID217 Input Input Fuji Electric FA Component & Systems Order code FCN connector type Output Input Output Note: When using A1SX42 and A1SY42, always use in combination with FMA-TF3120-MBA and FMA-TF3120-MBB, or FMA-TF3020-MBA and FMA-TF3020-MBB. Remark: The metal box to store the unit is also available as a special. ●32-input and output unit Compatible types OMRON Mitsubishi Electric C200H-ID216, CQM1-ID213, C500-ID219, C200H-ID217 FMA-TM1132-OR FMA-TL1132-OR 1 C200H-OD218, CQM1-OD213, C500-OD213, C200H-OD219 FMA-TM1032-OR FMA-TL1032-OR 1 Input A1SX41, AJ35TC1-32D, AX42, A1SX42 FMA-TM1132-MB FMA-TL1132-MB 1 Output A1SY41, AJ35TC1-32T, AY42, A1SY42 FMA-TM1032-MB FMA-TL1032-MB 1 FMA-TM1132-FJ FMA-TL1132-FJ 1 FMA-TM1032-FJ FMA-TL1032-FJ 1 Output SHARP YOKOGAWA ELECTRIC KOYO ELECTRONIC INDUSTRIES Hitachi Matsushita Electric Works KEYENCE FTU125A, NS-X64-I, NV1X3204(-W), NV1X3206 NC1X3204, NC1X3206, NC1X6404, NC1X6406 FTU222A, NS-Y64-TI, NV1Y32T05P1 NC1Y32T05P1, NC1Y64T05P1-1 DI335, DI-6241 FMA-TM1132-TB FMA-TL1132-TB 1 DO335, DO-6242 FMA-TM1032-TB FMA-TL1032-TB 1 Input JAMSC-B2605 FMA-TM1132-YS FMA-TL1132-YS 1 Output JAMSC-B2604 FMA-TM1032-YS FMA-TL1032-YS 1 Input JW-34NC, JW-234N, JW-64NC, JW-264N FMA-TM1132-SP FMA-TL1132-SP 1 Output JW-32SC, JW-232S, JW-62SC, JW-262S FMA-TM1032-SP FMA-TL1032-SP 1 Input F3XD32-3N, F3XD64-3N FMA-TM1132-YG FMA-TL1132-YG 1 Output F3YD32-1A, F3YD64-1A FMA-TM1032-YG FMA-TL1032-YG 1 Input U-09N FMA-TM1132-KD FMA-TL1132-KD 1 Output U-19T FMA-TM1032-KD FMA-TL1032-KD 1 XDC24D2H FMA-TL1132-HT 1 YTR24DH FMA-TL1032-HT 1 AFP23067, AFP33027, AFP33028, AFP33068 FMA-TL1132-MS 1 AFP23407, AFP33487 FMA-TL1032-MS 1 Input KZ-C32X FMA-TL1132-KY 1 Output KZ-C32T FMA-TL1032-KY 1 Input Output Input Output Input Output Remark: The metal box to store the unit is also available as a special. 1025 Package unit Input Input YASKAWA ELECTRIC MIL connector type Output Fuji Electric FA Component & Systems TOSHIBA Order code FCN connector type ●8-, 16-input and output unit I/O numbers/Specifications ●8 LO/HI-only input and output unit I/O numbers/Specifications Order code Package unit Order code Package unit 8-input/DIN rail mounting type FMA-TM1108 1 8 LO-only inputs/DIN rail mounting type FMA-TJ1108 1 16-input/DIN rail mounting type FMA-TM1116 1 8 HI-only inputs/DIN rail mounting type FMA-TK1108 1 8-input/Box-mounting type FMA-TM2108 1 8 LO-only inputs/Box-mounting type FMA-TJ2108 1 16-input/Box-mounting type FMA-TM2116 1 8 HI-only inputs/Box-mounting type FMA-TK2108 1 8-output/DIN rail mounting type FMA-TM1008 1 8 LO-only outputs/DIN rail mounting type FMA-TJ1008 1 16-output/DIN rail mounting type FMA-TM1016 1 8 HI-only outputs/DIN rail mounting type FMA-TK1008 1 8-output/Box-mounting type FMA-TM2008 1 8 LO-only outputs/Box-mounting type FMA-TJ2008 1 16-output/Box-mounting type FMA-TM2016 1 8 HI-only outputs/Box-mounting type FMA-TK2008 1 ●Connector type 8-, 16-input and output unit I/O numbers/Specifications ●16-output common reduction unit Order code Package unit 8-input (main)/DIN rail mounting type FMA-TC1108 1 8-input (sub-unit)/DIN rail mounting type FMA-TD1108 1 16-input/DIN rail mounting type FMA-TC1116 1 8-output (main)/DIN rail mounting type FAM-TC1008 1 8-output (sub-unit)/DIN rail mounting type FMA-TD1008 1 16-output/DIN rail mounting type FMA-TC1016 1 Number of outputs/Specifications 16-output/DIN rail mounting type Order code Package unit FMA-TH1016 1 ●32-output common reduction unit Order code Compatible models FCN connector type MIL connector type Package unit OMRON C200H-OD218, CQM1-OD213, C500-OD213, C200H-OD219 FMA-TH1032-OR FMA-TG1032-OR 1 Mitsubishi Electric A1SY41, AJ35TC1-32T, AY42, A1SY42 FMA-TH1032-MB FMA-TG1032-MB 1 Discontinued Fuji Electric FA Components & Systems FTU222A, NS-Y64-TI, NV1Y32T05P1, NC1Y32T05P1, NC1Y64T05P1-1 FMA-TH1032-FJ FMA-TG1032-FJ 1 TOSHIBA DO335, DO-6242 FMA-TH1032-TB FMA-TG1032-TB 1 JAMSC-B2604 FMA-TH1032-YS FMA-TG1032-YS 1 JW-32SC, JW-232S, JW-62SC, JW-262S FMA-TH1032-SP FMA-TG1032-SP 1 YOKOGAWA ELECTRIC F3YD32-1A, F3YD64-1A FMA-TH1032-YG FMA-TG1032-YG 1 KOYO ELECTRONIC INDUSTRIES U-19T FMA-TH1032-KD FMA-TG1032-KD 1 1 YASKAWA ELECTRIC SHARP Output Hitachi YTR24DH FMA-TG1032-HT Matsushita Electric Works AFP23407, AFP33487 FMA-TG1032-MS 1 KEYENCE KZ-C32T FMA-TG1032-KY 1 ●Unit for Mitsubishi Electric FX2, FX2C series only ●Connectors (For FX2-32MT-C, FX2-64MT-C, FX2C-64MT, FX2C-96MT, FX2C-128MT, FX2C-160MT) Parts Order code Package unit Remarks Order code Package unit 20 pins half pitch connector FMA-BF20HA 1 IDEC Izumi JM1S-0203 8-input/DIN rail mounting type FMA-TM1108-MB 1 20 pins flat cable connector FMA-BF20KA 10 Oki Electric Cable FL20A2FO 16-input/DIN rail mounting type FMA-TM1116-MB 1 34 pins flat cable connector FMA-BF34KA 1 Oki Electric Cable FL34A2FO 8-input/Box-mounting type FMA-TM2108-MB 1 40 pins flat cable connector FMA-BF40KA 1 Oki Electric Cable FL40A2FO 16-input/Box-mounting type FMA-TM2116-MB 1 24 pins 360 type connector FMA-BF24JA 1 Fujitsu FCN-367J024 8-output/DIN rail mounting type FMA-TM1008-MB 1 40 pins 360 type connector FMA-BF40JA 1 Fujitsu FCN-367J040 16-output/DIN rail mounting type FMA-TM1016-MB 1 10 Housing: 51103-0300 8-output/Box-mounting type FMA-TM2008-MB 1 30 Terminal: 50351-8100 16-output/Box-mounting type FMA-TM2016-MB 1 I/O numbers/Specifications 3 pins Molex connector set FMA-BM03A Order code (package unit) Parts Okiflex Connecting cableNote Okiflex with shield Crimping tool Remarks FMA-RCU16F (1 unit) Check unit 10 leads FMA-CX10×10 (10m [32.8ft.]), FMA-CX10×100 (100m [328ft.]) Flat cable with insulation containing power cable 20 leads FMA-CX20×20 (20m [65.6ft.]), FMA-CX20×100 (100m [328ft.]) Flat cable with insulation containing power cable 40 leads FMA-CX40×20 (20m [65.6ft.]), FMA-CX40×100 (100m [328ft.]) Flat cable with insulation containing power cable 20 leads FMA-CY20×20 (20m [65.6ft.]), FMA-CY20×100 (100m [328ft.]) Flat cable with insulation containing power cable 40 leads FMA-CY40×20 (20m [65.6ft.]), FMA-CY40×100 (100m [328ft.]) Flat cable with insulation containing power cable FMA-HT151 (1 set) Crimping tool for flat cable Note: Production of oil-resistant specifications, and deliveries in cable lengths other than package unit lengths, are also possible. Consult us. 1026 PC WIRING SYSTEM ●Check unit, connecting cable, and crimping tool Applicable Tools and Parts Applicable tools and parts for use when wiring PC Wiring System are available in other companies, see the table below: Parts Phillips’ screw driver Flatblade screw driver Heat-shrink tube FUE2 Order code Product number Package unit SD-3H1×75 994519 1 Made by Nihon Weidmuller SD 903700 1 Made by Nihon Weidmuller (Nominal size 10mm [0.39in.]) ― 1m [3.3ft.], 50m [164ft.] Made by Fujikura (for Okiflex 10 leads ) (Nominal size 13mm [0.51in.]) ― 1m [3.3ft.], 50m [164ft.] Made by Fujikura (for Okiflex 10, 20 leads) (Nominal size 16mm [0.63in.]) ― 1m [3.3ft.], 50m [164ft.] Made by Fujikura (for Okiflex 20, 40 leads) Remarks Crimp-style terminal (bar terminal) BT1.25-9-1 ― 1000 Crimper for crimp-style terminal HTN21 901471 1 H0.25/12 902576 500 Made by Nihon Weidmuller for 0.25mm2 [0.00039in.2] twisted wire (AWG24) H0.34/12 902577 500 Made by Nihon Weidmuller for 0.34mm2 [0.00053in.2] twisted wire (AWG22) H0.5/12 040950 500 Made by Nihon Weidmuller for 0.5mm2 [0.00078in.2] twisted wire (AWG20) H0.75/12 040960 500 Made by Nihon Weidmuller for 0.75mm2 [0.00116in.2] twisted wire (AWG18) H1/12 040970 500 Made by Nihon Weidmuller for 1.0mm2 [0.00155in.2] twisted wire (AWG17) PZ1.5 900599 1 Made by Nihon Weidmuller (for 0.25mm2∼1.5mm2 [0.00039∼0.00233in.2]) PZ4 901250 1 Made by Nihon Weidmuller (for 0.5mm2∼4mm2 [0.00078∼0.00620in.2]) RC80 901704 1 Made by Nihon Weidmuller Crimp-style sleeve Crimper for crimp-style sleeve Cutter for flat cable Made by Nichifu for 0.25∼1.65mm2 [0.00039∼0.00256in.2] Made by Nihon Weidmuller Discontinued 1027 Cable Assembly Order Codes Cable assemblies are made to order. For delivery, consult us. PCW - J400 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●A side (controller side) ●B side (PC side) 40 pins 360-type connector FCN-367J040 (Made by Fujitsu) 40 pins 360-type connector FCN-367J040 (Made by Fujitsu) Cable length A Compatible Equipment FCN connector type (40 pins) OMRON, Mitsubishi, TOSHIBA, Fuji Electric FA Components & Systems, YASKAWA ELECTRIC, SHARP, YOKOGAWA ELECTRIC, KOYO ELECTRONICS INDUSTRIES B1 A1 B20 A20 B Okiflex cable 40 leads A20 B20 A1 B1 B side power line※ A side power line※ ※End processing of power lines can vary depending on the power line specification. PCW - J40A 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line Discontinued 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●B side (PC side) ●A side (controller side) (300) Wires w/o end processing Wire number label Cable length Compatible Equipment Okiflex cable 40 leads PC, controller 40 pins 360-type connector FCN-367J040 (Made by Fujitsu) B A A20 B20 A1 B1 B side power line※ A side power line※ ※End processing of power lines can vary depending on the power line specification. PCW - J40Y 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. Wires w/o end processing, with Y terminals (300) Wire number label Cable Length A Okiflex cable 40 leads Compatible Equipment 40 pins 360-type connector FCN-367J040 (Made by Fujitsu) B A20 B20 A1 B1 PC, controller A side power line※ B side power line※ ※End processing of power lines can vary depending on the power line specification. Remark: Cable lengths of 20m [65.6ft.] or more are also available as a special. Consult us. 1028 PC WIRING SYSTEM ●B side (PC side) ●A side (controller side) Cable Assembly Order Codes Cable assemblies are made to order. For delivery, consult us. PCW - F400 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●A side (controller side) ●B side (PC side) 40 pins flat cable connector FL40A2FO (Made by Oki Electric Cable) or equivalent Cable length A B 39 (▲mark) 1 2 40 Okiflex cable 40 leads 40 pins flat cable connector FL40A2FO (Made by Oki Electric Cable) or equivalent Compatible Equipment MIL connector type (40 pins) Hitachi, Matsushita Electric Works (▲mark) 1 40 2 39 B side power line※ A side power line※ ※End processing of power lines can vary depending on the power line specification. PCW - F40A 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line Discontinued 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●B side (PC side) ●A side (controller side) Wires w/o end processing (300) Wire number label Cable length B A 2 Compatible Equipment 1(▲ mark) 40 pins flat cable connector FL40A2FO (Made by Oki Electric Cable) or equivalent Okiflex cable 40 leads PC, controller 40 39 B side power line※ A side power line※ ※End processing of power lines can vary depending on the power line specification. PCW - F40Y 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●B side (PC side) ●A side (controller side) Wires w/o end processing, with Y terminals (300) Wire number label Cable length B A 2 1(▲ mark) Okiflex cable 40 leads Compatible Equipment 40 pins flat cable connector FL40A2FO (Made by Oki Electric Cable) or equivalent PC, controller 40 A side power line※ Remark: Cable lengths of 20m [65.6ft.] or more are also available as a special. Consult us. 1029 39 B side power line※ ※End processing of power lines can vary depending on the power line specification. Cable Assembly Order Codes Cable assemblies are made to order. For delivery, consult us. PCW - G400 1 - A Connector No. Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●A side (controller side) ●B side (PC side) 40 pins 360-type connector FCN-367J040 (Made by Fujitsu) 40 pins flat cable connector FL40A2FO (Made by Oki Electric Cable) or equivalent Cable length B A Compatible Equipment 2 B1 A1 FCN connector type (40 pins) OMRON, Mitsubishi, TOSHIBA Fuji Electric FA Components & Systems, YASKAWA ELECTRIC, B20 SHARP, YOKOGAWA ELECTRIC, KOYO ELECTRONICS INDUSTRIES 1(▲ mark) Okiflex cable 40 leads ※End processing of power lines can vary depending on the power line specification. A20 40 A side power 39 Caution: This is for the types that the A and B connector numbers are mismatched. See the diagram on the right. B side power line※ line※ Sheathed wiring table B Connector No. A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10 A11 B11 A12 B12 A13 B13 A14 B14 A15 B15 A16 B16 A17 B17 A18 B18 A19 B19 A20 B20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 PCW - H200 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 4 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing Discontinued 5 6 7 (Relay terminal, others) 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal (For 8-, 16-signal input/output units) Note 300mm [11.8in.] with Y terminal 100mm [3.9in.] with round terminal (For Koganei F201 specification manifold) 100mm [3.9in.] with bar terminal 100mm [3.9in.] with Y terminal (Relay terminal, others) 100mm [3.9in.] with bar terminal 100mm [3.9in.] with bar terminal (For 8-, 16-signal input/output units)Note 100mm [3.9in.] with bar terminal 100mm [3.9in.] with round terminal (For Koganei F201 specification manifold) Remark: Y terminal is for M3.5, round terminal is for M3. ●A side (controller side) Compatible Equipment ●B side (PC side) Cable length 20 pins half pitch connector JM1S-0203 (Made by IDEC Izumi) A 11 (▲mark) 1 20 10 20 pins flat cable connector FL20A2FO (Made by Oki Electric Cable) or equivalent B Okiflex cable 20 leads (▲ mark) 1 2 20 Branch unit Direct connecting type A side power line※ 19 ※End processing of power lines can vary depending on the power line specification. Note: Can also handle connector type 8- and 16-input/ output units. B side power line※ PCW - F200 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 4 Without power line Without power line (Relay terminal, others) 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal (For 8-, 16-signal input/output units) Note 300mm [11.8in.] with Y terminal 100mm [3.9in.] with round terminal (For Koganei F201 specification manifold) 100mm [3.9in.] with bar terminal 100mm [3.9in.] with Y terminal (Relay terminal, others) 100mm [3.9in.] with bar terminal 100mm [3.9in.] with bar terminal (For 8-, 16-signal input/output units)Note 100mm [3.9in.] with bar terminal 100mm [3.9in.] with round terminal (For Koganei F201 specification manifold) PC WIRING SYSTEM 5 6 7 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing Remark: Y terminal is for M3.5, round terminal is for M3. ●A side (controller side) 20 pins flat cable connector FL20A2FO (Made by Oki Electric Cable) or equivalent ●B side (PC side) Cable length A Compatible Equipment Relay terminal Branch unit (Cannot select power line with Y terminal) 8-, 16-input/output unitNote (Cannot select power line with Y terminal) B 2 20 (▲ Mark) 1 Okiflex cable 20 leads 19 A side power line※ Remark: Cable lengths of 20m [65.6ft.] or more are also available as a special. Consult us. 2 20 B side power line※ (▲ Mark) 1 20 pins flat cable connector FL20A2FO (Made by Oki Electric Cable) or equivalent 19 ※End processing of power lines can vary depending on the power line specification. Note: Can also handle connector type 8- and 16-input/ output units. 1030 Cable Assembly Order Codes Cable assemblies are made to order. For delivery, consult us. PCW - F340 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●A side (controller side) ●B side (PC side) 34 pins flat cable connector FL34A2FO (Made by Oki Electric Cable) or equivalent Cable length A 33 B 34 2 1(▲ mark) 34 33 Okiflex cable 40 leads 34 pins flat cable connector FL34A2FO (Made by Oki Electric Cable) or equivalent Compatible Equipment MIL connector type (34 pins) KEYENCE (▲mark) 1 2 B side power line※ A side power line※ ※End processing of power lines can vary depending on the power line specification. PCW - F34A 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line Discontinued 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●B side (PC side) ●A side (controller side) Wires w/o end processing (300) Wire number label Cable length B A Compatible Equipment 2 1(▲ mark) 34 33 Okiflex cable 40 leads PC, controller B side power line※ A side power line※ 34 pins flat cable connector FL34A2FO (Made by Oki Electric Cable) or equivalent ※End processing of power lines can vary depending on the power line specification. PCW - F34Y 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 Without power line Without power line 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal Remark: Y terminal is for M3.5. ●A side (controller side) Wires w/o end processing, with Y terminals (300) Wire number label ●B side (PC side) Cable length B A 2 1(▲ mark) 34 33 Okiflex cable 40 leads Compatible Equipment 34 pins flat cable connector FL34A2FO (Made by Oki Electric Cable) or equivalent PC, controller A side power line※ Remark: Cable lengths of 20m [65.6ft.] or more are also available as a special. Consult us. 1031 B side power line※ ※End processing of power lines can vary depending on the power line specification. Cable Assembly Order Codes Cable assemblies are made to order. For delivery, consult us. PCW - J240 1 Cable length (m) Power line specification Note: Enter by the 0.5m pitch (MAX.20m [65.6ft.]). Code A side (controller side) B side (PC side) 0 1 2 3 4 Without power line Without power line Caution: The A and B side connector numbers are mismatched. See the diagram below. 300mm [11.8in.] wire w/o end processing 100mm [3.9in.] wire w/o end processing 300mm [11.8in.] with Y terminal 100mm [3.9in.] with Y terminal (Relay terminal, others) 300mm [11.8in.] with Y terminal 100mm [3.9in.] with bar terminal (For 8-, 16-input/output units)Note 300mm [11.8in.] with Y terminal 100mm [3.9in.] with round terminal (For Koganei F201 specification manifold) Remark: Y terminal is for M3.5, round terminal is for M3. ●B side (PC side) ●A side (controller side) 24 pins 360-type connector FCN-367J024 (Made by Fujitsu) Cable length A Compatible Equipment B1 FCN connector type (24 pins) B12 OMRON B Okiflex cable 20 leads A1 (▲ mark) 1 2 A12 20 19 B side power line※ A side power line※ 20 pins flat Cable connector FL20A2FO (Made by Oki Electric Cable) or equivalent ※End processing of power lines can vary depending on the power line specification. Note: Can also handle connector types 8- and 16-input/output units. A Connector No. A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10 A11 B11 A12 B12 Sheathed wiring table B Connector No. 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ●For connecting OMRON’s C500-ID218CN, C200H-ID215, C500-OD415CN, C200H-OD215, C500-MD211CN, or C200H-MD215 with 8- or 16-input/output units, manufacture and use the cable assemblies shown in the diagram below: Discontinued PC-side connector Made by Fujitsu FCN-365P024 PC-side applicable connector Made by Fujitsu FCN-367J024 Unit-side connector Made by Oki Electric Cable FL20A2MS Unit-side applicable connector Made by Oki Electric Cable FL20A2FO (equivalent) PC side Wiring diagram Unit side PC side Connector pin No. A B column column 1 1 1 2 2 3 3 2 ・・・・・・ ・・・・・・ 4 11 12 3 13 4 14 5 15 4 5 5 6 6 7 7 8 8 9 9 6 16 7 17 8 18 9 19 10 20 10 10 11 11 12 12 ▲ mark Note: The connector pin numbers are assigned for convenience. Use the ▲ mark as the reference. PC WIRING SYSTEM Remark: Although the method of pin No. identification varies, a cable assembly with connectors already crimped is available. The model is PCW-J240□-□. (See diagram above) 1032 PC Wiring System Connection Map Manifold solenoid valve A B A B A B A B A B A B A B (16-I/O×2) ×n Mitsubishi Electric FX2-32MT-C FX2-64MT-C FX2C-64MT FX2C-96MT FX2C-128MT FX2C-160MT With I/O connector micro sequencer Caution: Input/output unit for FX2, FX2C series is a specialized unit 32-I/O (16-I/O×2) OMRON Input : C500-ID218CN, C200H-ID215 Output : C500-OD415CN, C200H-OD215 Combination : C500-MD211CN, C200H-MD215 Note : When connecting the above input/ output cards, please refer to p.1032. ●F series solenoid valves Wiring specifications : -F201 type (Positive common specification) ●FM Solid Manifold X80M, X88M series Wiring module : FMCR-F201, FMC-F201 type (Positive common specification) Cable Assembly PCW-F200□ Cable Assembly PCW-J240□ 24P 24P PC multi-signal I/O unit Branch unit (Direct connecting type) OMRON Note Input : C500-ID219, C200H-ID217, C200H-ID216,CQM1-ID213 Note Output : C500-OD213, C200H-OD219, C200H-OD218, CQM1-OD213 Mitsubishi Electric Input : AX42, A1SX42, A1SX41 Output : AY42, A1SY42, A1SY41 Fuji Electric FA Components & Systems. Input : FTU125A, NS-X64-I, NV1X3204 (-W), NV1X3206 64-I/O NC1X3204, NC1X3206, NC1X6404, NC1X6406 (32-I/O×2) Output : FTU222A, NS-Y64-TI, NV1Y32T05P1 出力 : NC1Y32T05P1, NC1Y64T05P1-1 TOSHIBA Input : DI335, DI-6241 32-I/O Output : DO335, DO-6242 (32-I/O×1) YASKAWA ELECTRIC Input : JAMSC-B2605 40P Output : JAMSC-B2604 SHARP Input : JW-64NC, JW-34NC, JW-234N, JW-264N Output : JW-62SC, JW-32SC, JW-232S, JW-262S YOKOGAWA ELECTRIC Input : F3XD64-3N, F3XD32-3N Output : F3YD64-1A, F3YD32-1A KOYO ELECTRONICS INDUSTRIES Input : U-09N 40P (34P) Output : U-19T Direct connecting type For OMRON and Mitsubishi Electric only Cable Assembly PCW-H200□ Discontinued 40P PC multi-signal I/O unit Matsushita Electric Works Input : AFP23067, AFP33027, AFP33028, AFP33068 Output : AFP23407, AFP33487 Hitachi Input : XDC24D2H Output : YTR24DH KEYENCE Input : KZ-C32X Output : KZ-C32T Note: The branch unit (direct connecting type) is not applicable. 32-I/O×1 Mitsubishi Electric Input : AJ35TC1-32DNote Output : AJ35TC1-32T Note 40P Serial remote connector I/O unit Note: The branch unit (direct connecting type) is not applicable. ●For models other than those listed above, consult us. 1033 For input : FMA-TF3120-□ For output : FMA-TF3020-□ Cable Assembly PCW-F200□ Branch unit 32-I/O →16-I/O ×2 Cable Assembly PCW-J400□ For input : FMA-TF4120-□ For output : FMA-TF4020-□ Cable Assembly For input : FMA-TE4120-□ PCW-G400□ For output : FMA-TE4020-□ PCW-F400□ PCW-F340□ Cable Assembly PCW-G400□ PCW-F400□ PCW-F340□ Serial transmission sub-station OMRON 8-input/output Unit (Box-mounting type) SYSMAC BUS/2 G700-EOD32(Output 16×2) G700-EID32(Input 16×2) G700-EMD32(Output 16×1, Input 16×1) SYSBUS G71-OD16(Output 16×1) G71-IC16(Input 16×1) OMRON G7 0 0 - 8-input/output Unit 20P 20P For input : FMA-TM1108 For output : FMA-TM1008 For input : FMA-TK1108 For output : FMA-TK1008 For input : FMA-TM2108 For output : FMA-TM2008 For input : FMA-TK2108 For output : FMA-TK2008 ※Cascade connection (2 units) possible ※Cascade connection (2 units) possible Cable Assembly PCW-F200□ Cable Assembly PCW-F200□ 8-input/output Unit (Box-mounting type) 8-input/output Unit For input : FMA-TM1108 For output : FMA-TM1008 For input : FMA-TJ1108 For output : FMA-TJ1008 Discontinued For input : FMA-TM2108 For output : FMA-TM2008 For input : FMA-TJ2108 For output : FMA-TJ2008 16-input/output Unit (Box-mounting type) 16-input/output Unit For input : FMA-TM1116 For output : FMA-TM1016 ※Unable to increase units. Cable Assembly PCW-J400□ For input : FMA-TM2116 For output : FMA-TM2016 Check Unit 32-input/output Unit For input : FMA-TM1132-□ For output : FMA-TM1032-□ FMA-RCU16F For input : FMA-TL1132-□ For output : FMA-TL1032-□ PC-VALVE UNIT(8 outputs) PCV201□ PWR SND PC WIRING SYSTEM ※ : Marks where the check units can be connected. 1 2 3 4 5 6 7 8 1 2 3 4 FMA-TF2010 Wiring branch unit (16 outputs → 8 outputs×2) 5 20P 20P 10P 6 10P 7 (FMA-AF101-F-###) FMA-TF2010 ※Refer to PC-VALVE UNIT(p.790) . 8 PC-VALVE UNIT 1034 Connection Example between Branch Unit and Equipment The following products can also be directly connected to the various companies’ programmable controllers to reduce wiring. KEYENCE Output side Input side Branch unit Branch unit (Direct connecting type) OMRON I/O relay terminal G7TC-OC16 G7TC-OC08 I/O terminal P7TF-OS16 P7TF-OS08 Optical fiber sensor O-line type Relay terminal G7VC-OC16 G7VC-OA16 G7VC-OD16 OMRON Relay terminal socket G7OA-ZOS16-3 I/O relay terminal GT7TC-ID16 GT7TC-IA16 I/O terminal P7TF-IS16 Discontinued Motherboard M7E Matsushita Electric Works RT2 relay terminal RT2S-ID16 RT2S-C-ID16 RT2S-M-ID16 RT2S-MC-ID16 AAA 0 1 2 3 4 5 6 7 8 9 A B C D E F Digital indicator unit M7F-*N*** M7F-*D*** PC relay terminal RT1S-ID16-**V-S RT1S-ID08-**V-S Matsushita Electric Works D P ・ N E R ・ C O N E C T O R PC Terminal RT1-ID16-**V-S RT1-ID08-**V-S RT1-ID04-**V-S RT1-IA16-**V-S RT1-IA08-**V-S RT1-IA04-**V-S RT2 relay terminal RT2S-OD16 RT2S-C-OD16 RT2S-M-OD16 RT2S-MC-OD16 AAA 0 1 2 3 4 5 6 7 8 9 A B C D E F PC relay terminal RT1S-OD16-**V-S RT1S-OD08-**V-S SUNX Sensor main block SL-BMW 1035 D P ・ N E R ・ C O N E C T O R PC terminal RT1-OD16-**V-S RT1-OD08-**V-S RT1-OD04-**V-S RT1-OD02-**V-S