Transcript
D-Guard2 14.2.4 Calibration Fault 14.2.5 If the detector has been re-configured to a different type via the system menu, the calibration state of the instrument is returned to the default condition as new – i.e. not calibrated. The instrument requires a zero and full scale calibration following a sensor type change. To indicate that a calibration is required, the display indicates the warning message ‘CALIBRATION FAULT’. This message automatically clears once the calibrations are completed. 15. 15.1.1 Internal Parameter Storage Fault During the detector’s start up sequence, critical calibration and configuration data that is stored in the instruments non-volatile memory is checked for consistency. The same checks are made when any calibration of configuration parameters are changed b the user. If the stored data has become corrupted the display will indicate a warning message to show that either the calibration or configuration system data is not healthy. To clear this warning, try recalibrating or reconfiguring the detector. If these steps do not clear the fault, please call GasTech Australia for advice. Alarm Indication Warn Alarm Indication 15.1.2 Danger Alarm Indication If the measured gas concentration reaches the set-point programmed into the detector for a warn condition, the detector will signal this via a message in the lower status bar. Additionally a static alarm bell icon will be displayed. If the detector has relays fitted, the warn relay will activate. The behaviour of the alarm bell icon will depend on whether latching or non-latching alarms have been configured. If the measured gas concentration reaches the set-point programmed into the detector for a danger condition, the detector will signal this via a prominent message in the lower status bar. Additionally a flashing alarm bell icon will be displayed. If the detector has relays fitted, the danger relay will activate. The behaviour of the alarm bell icon will depend on whether latching or non-latching alarms have been configured. 15.1.3 15.1.4 Latched Alarm Indication If the condition that triggered an alarm response has subsided and the detector's alarms have been set to 'latched', the bell icon will be indicated in inverse colour. If the alarm condition was at warn level, the bell icon will be static. If the alarm condition was at danger level, the bell icon will be flash. Resetting From Alarm State If the detector alarms are set to non-latching, the alarm state will automatically clear once measured gas concentration has dropped below the set-point (including any set hysteresis value). If alarms are set to latched mode, they must be manually cleared once it has been determined that it is safe to do so. To reset the alarms, unlock the system menu and use the i soft-key to navigate to the detector status screen. 49