Download January 21, 2009
Transcript
2.3.5 Craft Terminal Each SDH equipment on the telecom network shall include provision for connecting a portable personal computer (PC) to be known as craft terminal to support local commissioning and maintenance activities. It shall also be possible to remote login to other NE(s) through craft terminal. Through the use of this PC and local displays/controls, the operator shall be able to: 2.3.6 a. Change the configuration of the station & the connected NEs. b. Perform tests c. Get detailed fault information Hardware Requirements 2.3.6.1 Master Processor, Server/Workstation and Craft Terminal The server/workstation and craft terminal shall have Dual Core processor(s) which shall be sufficient to meet all the functional requirement and expansion capabilities stipulated in this specification. Only reputed make like Dell, IBM, HP make shall be supplied. The server shall have minimum configuration of 3GHz for CISC based or 1.6GHz for RISC based processor, 2GB RAM, DVD-ROM drive, redundant 80 GB internal Hard Disk Drive, 101-Enhanced style keyboards, mouse, parallel, serial and USB(2.0) ports. VDUs shall be 17" TFT active matrix color LCD with a minimum resolution of 1024 X 768. Appropriate network drive card shall also be provided wherever required. However, the internal hard disk drive for the server shall be redundant and all the data shall be mirrored. Further, the TMN software shall support data mirroring on redundant disk drives. The workstation shall have minimum configuration of 2.4Ghz for CISC or 1.4GHz for RISC based processor, 1GB RAM, DVD-RW drive, 160 GB Hard Disk Drive, 101Enhanced style keyboards, mouse, parallel, serial and USB (2.0) ports. VDUs shall be 19" TFT active matrix color LCD with a minimum resolution of 1024 X 768. Appropriate network drive card shall also be provided wherever required. CPU enclosures shall be desktop type and shall include available expansion slots except for the Craft Terminal which shall be a laptop. The craft terminal shall have minimum configuration of 1.83 GHz, 1GB RAM, 256 MB VRAM, DVD RW drive, 100 GB Hard Disk Drive, keyboard, mouse/trackball etc., LAN, serial/USB (2.0) ports to accommodate printers, and Internal/external Data/Fax modem and a battery back-up of at least 60 minutes. VDUs shall be 15" TFT active matrix color LCD with a minimum resolution of 1024 X 768. 2.3.6.2 Peripherals and hardware TMN system shall be provided with laser printer. The laser printer shall have a minimum print speed 17 pages per minute and a minimum resolution of 600 dpi x 600 dpi. The laser printer shall have USB (2.0) & LAN port for connecting to TMN system. RFO-SDH-41E.doc Page 35 of 83