Download myUTN User Manual Linux
Transcript
Maintenance 7 Maintenance What Information Do You Need? Various maintenance activities can be carried out on the UTN server. This chapter contains information on securing and resetting the parameter values. You will also learn how to carry out a restart and a device update. • ’How to Secure UTN Parameters (Backup)’ 103 • ’How to Reset the UTN Parameters to their Default Values’ 106 • ’How to Perform an Update’ 108 • ’How to Restart the UTN Server’ 109 7.1 How to Secure UTN Parameters (Backup) All parameter values of the UTN server (exception: passwords) are saved in the '>default name>_parameters.txt' file. You can save the parameters file as backup copy on your local client. This allows you to get back to a stable configuration status at any time. You can edit the parameter values of the copied file using a text editor. Afterwards, the configured file can be downloaded to one or more UTN servers. The parameter values included in the file will be taken over by the device. Automatic Backup (myUTN-800 Only) The Dongleserver myUTN-800 additionally has an automatic backup feature. It saves the parameter values (exception: passwords) and certificates installed on the UTN server automatically to a connected SD card. After a parameter or certificate change, the backup will be updated automatically. If the SD card is lost or stolen, your environment becomes vulnerable (certificates, passwords). Therefore, you have to take all necessary precautions for protecting the myUTN-800 if you use the automatic backup. myUTN User Manual Linux 103