Chapter 5 – Reference Pause biCoder The BL-5402 is a biCoder which connects directly to the two-wire, and provides a set of wires that can be connected to a set of normally closed contacts. When the contacts open, a pause condition is sensed by the controller and the associated programs move to a paused state for a specified amount of time. Pause Button The BL-5401 is an outside mountable box with a push button and light. This can be used to pause the watering program and is sometimes referred to as a coach’s button. This pause button allows him to stop the watering during a practice without the use of a baseball bat. Valve biCoders Field biCoders Field biCoders come in three configurations: BL-5201 – 1-valve direct bury biCoder BL-5202 – 2-valve direct bury biCoder BL-5204 – 4-valve direct bury biCoder These valve biCoders attach directly to the two-wire and are capable of activating standard 24 VAC valves (solenoids). The measure the voltage and current delivered to the solenoid and communicate these values back to the controller. If a solenoid becomes shorted, the biCoder will automatically deactivate so as to not cause an excessive current draw on the two-wire that could affect other devices. They have internal surge protection and have a have a two-wire clamping circuit that will short the two-wire when it detects a very high surge (such as lightning induced) to help protect other electrical devices connected to the two-wire path. Powered biCoders Baseline powered biCoders are available in a number of configurations, both in valve count and in cabinet options. The basic component is either a 12 or 24 zone printed circuit board. This board communicates with the BaseStation 3200 controller over the two-wire path, but receives its power from a separate 24 VAC transformer. This board level biCoder is available in a standalone cabinet, or it can be built into the BL-3200X series controller. This biCoder uses conventional valve wiring – each valve has a direct wire to the biCoder as well as a shared common wire. These powered biCoders work very well for retrofit projects where existing valve wires are already in use and are of good Page 75 Baseline 3200