Download PEL 102 PEL 103
Transcript
A.6 GLOSSARY OF TERMS Symbol or Terminology Description AC and DC components. AC component only. DC component only. Inductive phase shift. Capacitive phase shift. ° Degree. % Percentage. CF Crest factor (Peak Factor) in current or voltage: ratio of the peak value of a signal to the RMS value. Cos ϕ Cosine of the phase shift of the fundamental voltage with respect to the fundamental current. DC DC component (current or voltage) Ep Abbreviation for active energy. Eq Abbreviation for reactive energy. Es Abbreviation for apparent energy. Frequency Fundamental Component Number of full voltage or current cycles in one second. Component at the fundamental frequency. Hz In electrical systems, voltages and currents at frequencies that are multiples of the fundamental frequency. Frequency of network studied. I Abbreviation for current. I-CF Crest (peak) factor of current. I-THD Total harmonic distortion of current. Ix-Hh Current value or percentage for harmonic rank n. L Phase (Line). MAX Maximum value Measurement Method All measurement methods associated to an individual measurement. MIN Minimum value Nominal Voltage Reference voltage of a network. P Abbreviation for active power. PF Power Factor: ratio of active power to apparent power. Phase Temporal relationship between current and voltage in alternating current circuits. Q Abbreviation for reactive power. Rank of a Harmonic Ratio of the frequency of the harmonic to the fundamental frequency; a whole number. RMS (Root Mean Square) value of current or voltage. Square root of the mean of the squares of the instantaneous values of a quantity during a specified interval. Abbreviation for apparent power. Harmonics RMS S Tan Φ U Ratio between reactive power and active power. Total Harmonic Distortion. The total harmonic distortion describes the proportion of the harmonics of a signal with respect to the fundamental RMS value (%f). Phase-to-phase voltage U-CF Phase-to-phase voltage crest factor Uh Unbalance in voltage in a polyphased electrical power network Ux-Hn Phase-to-phase voltage harmonic Uxy-THD Total phase-to-phase voltage harmonic distortion. V Abbreviation for phase-to-neutral voltage or the unit “volt”. THD 94 Status where efficient values for voltages between conductors (fundamental component) and/or differences in phase between successive conductors are not equal. Phase-to-phase voltage value or percentage for harmonic rank n. Power & Energy Logger Model PEL 102 and PEL 103