EC-20, EC-10 and EC-5 User’s Manual 4. Collecting Data ting Mix, and Custom Nursery soil) at several salinities and found that VWC is given by ø = 7.2 * 10-4 * Raw - 0.393(3) for a Decagon datalogger or ø = 10.3 * 10-4 * mV - 0.334 (4) for a datalogger with 2500mV excitation. Rockwool The EC-5 was calibrated in Grodan Master rockwool with solution electrical conductivities of 0.2, 1.0, 1.5, 2.0, and 4.5 dS/m. Volumetric water content can be calculated using ø = 6.28 * 10-7 * Raw2 + 1.37 x 10-4 * Raw - 0.183(5) for a Decagon datalogger or ø = 2.63 * 10-6 * mV2 + 5.07 x 10-4 * mV - 0.0394(6) for a datalogger with 2500 mV excitation. NOTE: These calibration constants only apply to 2500mV excitations; use of these numbers with any other excitation voltage will result in erroneous readings! 18