Download DUAL GAUGE PRO DPW USER`S MANUAL
Transcript
(DPW As of July, 2015 No.1) USER’S MANUAL Easy Installation WATER TEMP+DIGITAL Thank you for purchasing this PIVOT product. Please read this manual carefully and keep it for future reference. ● If this produc t is given to another user, make sure to include this User’s Manual. Product DPW Designed for Subaru BRZ and Toyota 86 Models + Contents Please check the contents of the package Contents / WARNING / CAUTION ……… 1 Features …………………………………… 1 Part Names and Displays ……………… 1 Wiring Method and Installation ………… 2 Installing with Insert Holder ……………… 2 ~3 Installing without Insert Holder ……………… 3 Basic Operation …………………………… 4 Switching The Display …………………… 4 Illumination color settings ……………… 4 Illumination brightness settings………… 4 Troubleshooting …………………………… 4 Meter A-pillar Stand Gauge Cable Unit Screw Allen Wrench Nut OBD Cable with Fuse 3A Double-sided Tape IGN Cable with Fuse 3A Cushion Tape (Wide) × 1 (Narrow) × 1 Cut Connectors ×2 Insert Holder Meter Holder Zip Ties User’s Manual (Large) × 2 (This Book) (Small) × 5 1. The display will not be proper if the ECU being used is not the standard one or if a sub-computer is being used, even in compatible car models. 2. Cannot be used in combination with other company’s products that use Diagnostic Monitoring Connectors. 3. For details about using combinations of PIVOT OBD2 products, see here. ⇒ http://pivotjp.com/obd/ WARNING Improper use or disregard of these warnings may result in the injury or death of people. CAUTION ●This product is for DC12V cars; ●Do not work in areas where there is excessive exhaust. Due to vehicle exhaust emission poisoning or fire may result in a damage to humans. ●Do not crush the cable. Please be careful that the cable does not get crushed by the seat rail or car door steel plate, nor cut by any sharp steel plate as this may cause a poor connection or an electric short leading to fire or other danger. Installation cannot be carried out on cars with other voltage batteries. ●Just after installation do not exert any strong force on the product. When double-sided tape is used for an installation be warned that when hot the tape temporarily losses adhesiveness. ●Do Not Use Chemical Cleansers. If the unit gets dirty please wipe with a soft cloth to remove any dirt. Do not use chemical cleansers such as thinner, benzene, or alcohol. ●Do not operate while driving. Operating or checking the display during driving may cause an accident; please use with the utmost consideration for safety. ●Please securely fasten the product to a stable place and be sure to store bundle away all wires with tape, etc... It is very dangerous to pull tangled wires by force or allow tangled wires to interfere with driving. Features ●Do not install the product in any place subject to high temperature or any place where water may be splashed. ●Make sure to replace all screws and parts to their original place. ●Do not install the product in a place where it will cause distraction. ●Do not, in any manner, process, take apart, or make changes to this product. Part Names and Displays Scale designed to match maker gauges, this can switch illumination color between red and white and comes with specialized holder for installation to air vents. 1 Analog Display Display Water Temp data. 2 Needle Shows the current values and peak value. 3 Switch Use to change modes of digital display and reset the peak value. 4 Digital Display Display switches between types. 5 Illumination Normally illuminated when on display and Three-step dimming. (night illumination) 2 Improper use or disregard of these warnings may cause injury to persons, damage the product and other things. Size 1 Analog Display Dial and Needle: White or Red (switchable) 3 Digital Display Red Analog Display Water Temp [ -35 〜 150 °C ] Digital Display Voltage [ 8 〜 18V] Oil Temp [ -35 〜 150 °C ] 4 6 Display Range [Unit:mm] Meter 15 30 ø60 ø65 Unit 70 50 Depth22 1 Wiring Method and Installation Basic Wiring Please carry out wiring with the engine turned OFF and the key removed. Installation Example Meter Backside of the meter Diagnostic Monitoring Connector 2-pin Connector 4-pin Connector (not used) OBD Connector (1.5 m) 3-pin Connector Connect to the Diagnostic Monitoring Connector (0.5 m) (not used) Unit 6-pin Connector 5-pin Connector Unit If the meter not activate from individual differences in car models or some reasons after the engine starts, change the power source and connect the power cable to IGN. ⇒See page 3【If connect the power cable to IGN (Not normally required)】. Installing the product with Insert Holder 1 Remove the Covers Remove in the order of ① - ③. =Place of clip and hook 2 Pulling out the air vent Remove the air vent (Hook 3 places) =Place of hook 3 Affix the Cushion Tape to the supplied Insert holder ① Side panel (Clip 4 places, Hook 1 place) ② Screw 2 places Cushion tape (Wide) (3 places) ③ Under cover (Clip 4 places, Hook 4 places) 4 Decompose the air vent and replace the Air vent part C to the Insert Holder ① Air vent part A ② Air vent part B (Hook 3 places) (Hook 3 places) Air vent part C 6 Pull the cable through the hole made at 5 from the back side of the air vent, then return the air vent to its original position Air vent part D Pull the cable from back side of the air vent 4-pin Connector Fan duct Through the hole 7 Decompose the air vent in the order of ① - ②. Then replacing the Air vent part C to the Insert Holder, and go back to the original in the reverse order. Insert Holder Replace the Air vent part C to the Insert Holder Affix the Cushion Tape to the base of the meter and connect the 4-pin connector through out the air vent at 6 . Then press into the Insert Holder combined with the air vent. Cushion Tape (Wide) (3 places) Cushion Tape (Wide) (3 places) 4-pin Connector 5 Make a hole on fan duct to put through the cable 8 Make a hole with things like a cutter knife in fan duct (flat area of the fan duct of car side) to put through the cable. 10mm or more Fan duct Make a hole in this area 2 Size of the hole 9 Connect 5-pin connector and 6-pin connector(power cable) , then fasten the unit. ⇒See page 3 ※1【Installing The Unit】 Connect the power cable to the Diagnostic Monitoring Connector, and bind the extra cables. 6mm or more 10 Return the panels to its original place by going in the reverse order from 1 . ※1 Installing The Unit (Example of Installation) On the back side of the under cover As shown in the right diagram , fasten the unit into positions not usually af fected by water. Fastening to Flat Space On the inside of the driver’s door When Fastenings to a Cable or Pipe Zip tie (Large) Unit Double-sided tape Through holes Clean to remove oil and dust. Do not install into low positions Thick cable or pipe Installing the product without Insert Holder ・Decide a install location of the meter and connect the 4-pin connector, then fasten the meter. ・Connect 5-pin connector and 6-pin connector(power cable) , then fasten the unit. ⇒See ※1【Installing The Unit】above. ・Connect the power cable to the Diagnostic Monitoring Connector, and bind the extra cables. Installing The Meter A Installation with the Meter Holder ① Fa s t e n u s i n g t h e double-sided tape. ③ Affix the Cushion Tape (Narrow) to the base of the meter, connect the Gauge Cable to the Meter, and install the Meter into the Meter Holder. Please add the Cushion ② After deciding the position and angle of the meter face, fasten the Hexagonal bolt on both sides to secure. Tape if the Meter not fixed. Cushion Tape (Narrow) Double-sided tape Cushion Tape (Narrow) Meter Holder Clean to remove oil and dust Back side of Meter Note : Please be sure about where you wish to install the meter, as it is not advisable to reuse double-sided tape. Cushion Tape (Narrow) Hexagonal bolt B Installation to panel or something Gauge Cable Connector C Installation to A-pillar using A-pillar Stand Cut the Cushion Tape (Narrow) in half, affix to base of the Meter to be on press fit condition with adjusting number. And connect the Gauge Cable to the Meter and insert into the panel. Make a ø5 hole on the place to install the meter of the A-pillar, and fix the Meter using A-pillar Stand with Screw and Nut. A-pillar Cushion Tape (Narrow) A-pillar Panel Screw Nut Gauge Cable Cut the Cushion Tape(Narrow) in half A-pillar Stand Cushion Tape (Narrow) ø5 Hole If connect the power cable to IGN (Not normally required) The meter start-up and stop is differ in power connection method. Normal (not using IGN Cable) Linked to the key switch Linked to the ECU Diagnostic Monitoring Connector OBD Cable IGN (using IGN Cable) Red Unplug the connector of Yellow and Red cable of OBD Cable and connect Yellow cable of IGN Cable into the connector on Yellow cable, then connect to IGN cable to IGN of car. (Do not connect to Acc) Yellow =Cut Connector IGN Yellow IGN Cable (12V with Key ON) Notes about using the OBD Connector Make sure to grip the distended portions when pulling it out or inserting it. If you unable to get a grip on the distended portions. CAUTION D o n o t p u ll o n t h e w i r e s when trying to remove the connector; the wires may become disconnected. W i t h s o m e c ar m o d e l s i t m ay b e d i f f i c u l t t o g e t a good grip on the connector. In such case, pull out the connector by p u l l i n g o n t h e end of the zip tie. How to use the Cut Connectors 1 10 mm Peel off of the vinyl cover at connection. 2 10 mm Peel off of the vinyl cover at the end of the product’s wire. 3 4 5 Wrap around both wire coils. Close tightly with cut connector. Insulate with vinyl tape. When crimping, please use crimpers or use pliers to bend and then solder together. 3 Basic Operation 1 2 Engine Start 3 Opening Demo 4 Display Each Mode 5 Engine Stop Meter OFF The needle stops in the vicinity of lowest value. Opening ●When the key is turned ON the needle will move to the extreme left several times for searching position. Then it will move to the maximum Demo Turning off ●Due to analyzation time for the car data transmission, the illumination may remain on for up to 1 minutes even after the Display value and finally to reading for current measurement item. the engine has been turned off; this is normal and no effect on the vehicle performance. (except wiring IGN) ●Due to analyzation time for the car data transmission it may take up to a few seconds from engine start before opening demo. Switching The Display Switching The Digital Display Press switch to change the multi-digital display in operation ※ Pe a k r e a d i n g s a r e r e s e t Display and Reset the Peak Value Voltage Real-time Display Oil Temp when the key is turned OFF. Peak Value Display for 3 Seconds for 3 Seconds Press Switch Press Switch (decimal point is lightning) Oil Temp Reading the Display [ - 35 〜 - 1 °C ] [ 0 〜 99 °C ] [ 100 〜150 °C ] The first place on the below shows “ ” (minus). The third place from the below shows “ ” (Celsius). Numerical Value Only. c - With no operation 5 Seconds (Lighting) Reset the Peak Value (Blinking) Only the peak value on display will be reset and return to the Real-time Display for the currently displayed mode. Illumination color settings 1 + ENGINE START STOP 2 3 Display the current illumination color setting Engine Start (e.g. After the meter off, Engine start during pressing the switch Press the switch to change the color c-1 ) 5 Release the switch after displayed the current setting [ c-1 = White, Press the switch for 6 seconds 2 Display a peak value after 3 seconds and the current brightness after 6 seconds Release the switch after setting is done Back to normal display with no operation for 5 seconds Setting Completed Adjustment in case of anxious about reflected illumination of door mirror or something 3 Holding downs the switch in operation (e.g. c-2 = Red ] Each pressing will change the color Illumination brightness settings 1 4 L-3 ) 4 Press the switch to change the brightness Release the switch after displayed the current setting (High) 5 Release the switch after setting is done 6 Back to normal display with no operation for 5 seconds (Mid) (Low) Each pressing will change the brightness Setting Completed Troubleshooting Trouble Does not work with Engine start. Possible Causes Possible Solutions Poor connection of Gauge cable , 6-pin Connector or OBD Connector wires. Pl e a s e r e c o n f i r m w h e t h e r w i r i n g a n d connections are correct or not. The unit has been installed into an incompatible car model. Please reconfirm the fitting list. Upon starting up, the unit will not start in the newly changed display. Because after changing displays, if the car’ s engine is turned off within 3 seconds, the new setting will not be stored, make sure to wait at least 3 seconds before turning the engine off. Before the opening demo starts the needle briefly moves. This is due to a special characteristic of the meter and is not a malfunction. The displayed values are different from the standard meter. Due to the ECU information received, the displayed values on this product may differ from those of standard or other meters. ※Our products have already been recognized as our Industrial Property or are in the process of receiving Industrial Property status. ※We plan in the near future to take all possible legal measures to protect against unfair competition from look-alike products using similar designs, regulating characteristics, circuitry and circuitry layout. ※We strictly prohibit the unlicensed use of the PIVOT trademark and the unauthorized use of PIVOT User’s Manual. 4 PIVOT CORPORATION 87-3, Shimookada Okada, Matsumoto-shi, Nagano, 390-0313 JAPAN