Download DUAL GAUGE PRO DPW USER`S MANUAL

Transcript
(DPW As of July, 2015 No.1)
USER’S MANUAL
Easy Installation
WATER TEMP+DIGITAL
Thank you for purchasing this PIVOT product.
Please read this manual carefully and keep it for future
reference.
● If this produc t is given to
another user, make sure to
include this User’s Manual.
Product
DPW
Designed for Subaru BRZ and Toyota 86 Models
+
Contents
Please check the contents of the package
Contents / WARNING / CAUTION ……… 1
Features …………………………………… 1
Part Names and Displays ……………… 1
Wiring Method and Installation ………… 2
Installing with Insert Holder ……………… 2 ~3
Installing without Insert Holder ……………… 3
Basic Operation …………………………… 4
Switching The Display …………………… 4
Illumination color settings ……………… 4
Illumination brightness settings………… 4
Troubleshooting …………………………… 4
Meter
A-pillar
Stand
Gauge
Cable
Unit
Screw
Allen
Wrench
Nut
OBD Cable
with Fuse 3A
Double-sided
Tape
IGN Cable
with Fuse 3A
Cushion Tape
(Wide) × 1
(Narrow) × 1
Cut
Connectors
×2
Insert
Holder
Meter
Holder
Zip Ties
User’s Manual
(Large) × 2
(This Book)
(Small) × 5
1. The display will not be proper if the ECU being used is not the standard one or if a sub-computer is being used, even
in compatible car models.
2. Cannot be used in combination with other company’s products that use Diagnostic Monitoring Connectors.
3. For details about using combinations of PIVOT OBD2 products, see here. ⇒ http://pivotjp.com/obd/
WARNING
Improper use or disregard of these warnings
may result in the injury or death of people.
CAUTION
●This product is for DC12V cars;
●Do not work in areas where there is excessive exhaust.
Due to vehicle exhaust emission poisoning or fire may result in a damage to
humans.
●Do not crush the cable.
Please be careful that the cable does not get crushed by the seat rail or car
door steel plate, nor cut by any sharp steel plate as this may cause a poor
connection or an electric short leading to fire or other danger.
Installation cannot be carried out on cars with other voltage batteries.
●Just after installation do not exert any strong force on the product.
When double-sided tape is used for an installation be warned that when hot the tape
temporarily losses adhesiveness.
●Do Not Use Chemical Cleansers.
If the unit gets dirty please wipe with a soft cloth to remove any dirt. Do not use chemical
cleansers such as thinner, benzene, or alcohol.
●Do not operate while driving.
Operating or checking the display during driving may cause an accident;
please use with the utmost consideration for safety.
●Please securely fasten the product to a stable place and be
sure to store bundle away all wires with tape, etc...
It is very dangerous to pull tangled wires by force or allow tangled wires to
interfere with driving.
Features
●Do not install the product in any place subject to high temperature or
any place where water may be splashed.
●Make sure to replace all screws and parts to their original place.
●Do not install the product in a place where it will cause distraction.
●Do not, in any manner, process, take apart, or make changes to this
product.
Part Names and Displays
Scale designed to match maker gauges, this can
switch illumination color between red and white
and comes with specialized holder for installation to air vents.
1 Analog Display
Display Water Temp data.
2 Needle
Shows the current values and peak value.
3 Switch
Use to change modes of digital display
and reset the peak value.
4 Digital Display
Display switches between types.
5 Illumination
Normally illuminated when on display
and Three-step dimming.
(night illumination)
2
Improper use or disregard of these warnings may cause
injury to persons, damage the product and other things.
Size
1
Analog Display
Dial and Needle: White or Red
(switchable)
3
Digital Display
Red
Analog Display
Water Temp [ -35 〜 150 °C ]
Digital Display
Voltage [ 8 〜 18V]
Oil Temp [ -35 〜 150 °C ]
4
6 Display Range
[Unit:mm]
Meter
15 30
ø60
ø65
Unit
70
50
Depth22
1
Wiring Method and Installation
Basic Wiring
Please carry out wiring with the engine turned OFF and the key removed.
Installation Example
Meter
Backside
of the
meter
Diagnostic
Monitoring Connector
2-pin Connector
4-pin
Connector
(not used)
OBD Connector
(1.5 m)
3-pin Connector
Connect to the Diagnostic
Monitoring Connector
(0.5 m)
(not used)
Unit
6-pin
Connector
5-pin
Connector
Unit
If the meter not activate from individual differences in car models or some reasons
after the engine starts, change the power source and connect the power cable to IGN.
⇒See page 3【If connect the power cable to IGN (Not normally required)】.
Installing the product with Insert Holder
1
Remove the Covers
Remove in the order of ① - ③.
=Place of clip and hook
2
Pulling out the air vent
Remove the air vent
(Hook 3 places)
=Place of hook
3
Affix the Cushion Tape to the
supplied Insert holder
① Side panel
(Clip 4 places,
Hook 1 place)
② Screw
2 places
Cushion tape (Wide)
(3 places)
③ Under cover
(Clip 4 places, Hook 4 places)
4
Decompose the air vent and replace the Air vent part C
to the Insert Holder
① Air vent part A ② Air vent part B
(Hook 3 places) (Hook 3 places)
Air vent part C
6
Pull the cable through the hole made at 5 from the
back side of the air vent, then return the air vent to
its original position
Air vent part D
Pull the cable
from back side
of the air vent
4-pin
Connector
Fan duct
Through the hole
7
Decompose the air vent in
the order of ① - ②. Then
replacing the Air vent part C
to the Insert Holder, and go
back to the original in the
reverse order.
Insert Holder
Replace the Air vent part C
to the Insert Holder
Affix the Cushion Tape to the base of the meter and
connect the 4-pin connector through out the air vent
at 6 . Then press into the Insert Holder combined
with the air vent.
Cushion
Tape (Wide)
(3 places)
Cushion Tape (Wide)
(3 places)
4-pin
Connector
5
Make a hole on fan duct to put through the cable
8
Make a hole with things like a cutter knife in fan duct (flat area of the
fan duct of car side) to put through the cable.
10mm or more
Fan duct
Make a hole
in this area
2
Size of
the hole
9
Connect 5-pin connector and 6-pin connector(power
cable) , then fasten the unit.
⇒See page 3 ※1【Installing The Unit】
Connect the power cable to the Diagnostic Monitoring Connector, and bind the extra cables.
6mm or more
10
Return the panels to its original place by going in the
reverse order from 1 .
※1
Installing
The Unit
(Example of Installation)
On the back side
of the under cover
As shown in the right
diagram , fasten the
unit into positions not
usually af fected by
water.
Fastening
to Flat Space
On the inside of
the driver’s door
When Fastenings to
a Cable or Pipe
Zip tie
(Large)
Unit
Double-sided
tape
Through
holes
Clean to
remove
oil and dust.
Do not install into low positions
Thick cable
or pipe
Installing the product without Insert Holder
・Decide a install location of the meter and connect the 4-pin connector, then fasten the meter.
・Connect 5-pin connector and 6-pin connector(power cable) , then fasten the unit. ⇒See ※1【Installing The Unit】above.
・Connect the power cable to the Diagnostic Monitoring Connector, and bind the extra cables.
Installing The Meter
A Installation with the Meter Holder
① Fa s t e n u s i n g t h e
double-sided tape.
③ Affix the Cushion Tape (Narrow) to the base of the meter, connect the Gauge Cable to
the Meter, and install the Meter into the Meter Holder. Please add the Cushion
② After deciding the position
and angle of the meter face,
fasten the Hexagonal bolt
on both sides to secure.
Tape if the Meter not fixed.
Cushion Tape
(Narrow)
Double-sided
tape
Cushion Tape
(Narrow)
Meter Holder
Clean
to remove
oil and dust
Back side
of Meter
Note : Please be sure about
where you wish to install the
meter, as it is not advisable to
reuse double-sided tape.
Cushion Tape
(Narrow)
Hexagonal bolt
B Installation to panel or something
Gauge Cable
Connector
C Installation to A-pillar using A-pillar Stand
Cut the Cushion Tape (Narrow) in half, affix to base of the Meter to be
on press fit condition with adjusting number. And connect the Gauge
Cable to the Meter and insert into the panel.
Make a ø5 hole on the place to install the meter of the A-pillar, and fix the
Meter using A-pillar Stand with Screw and Nut.
A-pillar
Cushion Tape (Narrow)
A-pillar
Panel
Screw
Nut
Gauge
Cable
Cut the Cushion
Tape(Narrow) in
half
A-pillar
Stand
Cushion Tape (Narrow)
ø5 Hole
If connect the power cable to IGN (Not normally required)
The meter start-up and stop is differ in power connection method.
Normal (not using IGN Cable)
Linked to the key switch
Linked to the ECU
Diagnostic
Monitoring
Connector
OBD Cable
IGN (using IGN Cable)
Red
Unplug the connector of Yellow and Red cable of OBD Cable and
connect Yellow cable of IGN Cable into the connector on Yellow cable,
then connect to IGN cable to IGN of car. (Do not connect to Acc)
Yellow
=Cut Connector
IGN
Yellow
IGN Cable
(12V with Key ON)
Notes about using the OBD Connector
Make sure to grip the
distended portions when
pulling it out or inserting it.
If you unable to get a grip
on the distended portions.
CAUTION
D o n o t p u ll o n t h e w i r e s
when trying to remove the
connector; the wires may
become disconnected.
W i t h s o m e c ar m o d e l s i t
m ay b e d i f f i c u l t t o g e t a
good grip on the connector.
In such case, pull
out the connector
by p u l l i n g o n t h e
end of the zip tie.
How to use the Cut Connectors
1
10 mm
Peel off of the vinyl cover
at connection.
2
10 mm
Peel off of the vinyl cover at
the end of the product’s wire.
3
4
5
Wrap around both wire
coils.
Close tightly with cut
connector.
Insulate with vinyl tape.
When crimping, please
use crimpers or use
pliers to bend and then
solder together.
3
Basic Operation
1
2
Engine Start
3
Opening Demo
4
Display Each Mode
5
Engine Stop
Meter OFF
The needle stops in the
vicinity of lowest value.
Opening ●When the key is turned ON the needle will move to the extreme left
several times for searching position. Then it will move to the maximum
Demo
Turning off ●Due to analyzation time for the car data transmission, the
illumination may remain on for up to 1 minutes even after
the Display
value and finally to reading for current measurement item.
the engine has been turned off; this is normal and no
effect on the vehicle performance. (except wiring IGN)
●Due to analyzation time for the car data transmission it may take up to
a few seconds from engine start before opening demo.
Switching The Display
Switching The Digital Display
Press switch to change
the multi-digital display
in operation
※ Pe a k r e a d i n g s a r e r e s e t
Display and Reset the Peak Value
Voltage
Real-time Display
Oil Temp
when the key is turned OFF.
Peak Value Display
for 3 Seconds
for 3 Seconds
Press
Switch
Press
Switch
(decimal point
is lightning)
Oil Temp Reading the Display
[ - 35 〜 - 1 °C ]
[ 0 〜 99 °C ]
[ 100 〜150 °C ]
The first place on the
below shows “ ” (minus).
The third place from the
below shows “ ” (Celsius).
Numerical Value
Only.
c
-
With no operation
5 Seconds
(Lighting)
Reset the Peak Value
(Blinking)
Only the peak value on display will be reset and return
to the Real-time Display for
the currently displayed mode.
Illumination color settings
1
+
ENGINE
START
STOP
2
3
Display the current
illumination color setting
Engine Start
(e.g.
After the meter off,
Engine start during
pressing the switch
Press the
switch to change
the color
c-1 )
5
Release the switch
after displayed
the current setting
[ c-1 = White,
Press
the switch
for 6 seconds
2
Display a peak value after
3 seconds and the current
brightness after 6 seconds
Release the switch
after setting is done
Back to normal display with
no operation for 5 seconds
Setting Completed
Adjustment in case of anxious about reflected illumination of door mirror
or something
3
Holding downs the switch in operation
(e.g.
c-2 = Red ]
Each pressing will change the color
Illumination brightness settings
1
4
L-3 )
4
Press the switch
to change the brightness
Release the switch
after displayed
the current setting
(High)
5
Release
the switch
after setting is done
6
Back to normal display with
no operation for 5 seconds
(Mid)
(Low)
Each pressing will change the brightness
Setting Completed
Troubleshooting
Trouble
Does not work with Engine start.
Possible Causes
Possible Solutions
Poor connection of Gauge cable ,
6-pin Connector or OBD Connector wires.
Pl e a s e r e c o n f i r m w h e t h e r w i r i n g a n d
connections are correct or not.
The unit has been installed into an incompatible
car model.
Please reconfirm the fitting list.
Upon starting up, the unit will not start in the
newly changed display.
Because after changing displays, if the car’ s engine is turned off within 3 seconds, the new
setting will not be stored, make sure to wait at least 3 seconds before turning the engine off.
Before the opening demo starts the needle briefly moves.
This is due to a special characteristic of the meter and is not a malfunction.
The displayed values are different from the standard
meter.
Due to the ECU information received, the displayed values on this product may differ from those
of standard or other meters.
※Our products have already been recognized as our Industrial Property or are in the process of receiving Industrial Property status.
※We plan in the near future to take all possible legal measures to protect against unfair competition from look-alike products using similar designs, regulating characteristics,
circuitry and circuitry layout.
※We strictly prohibit the unlicensed use of the PIVOT trademark and the unauthorized use of PIVOT User’s Manual.
4
PIVOT CORPORATION 87-3, Shimookada Okada, Matsumoto-shi, Nagano, 390-0313 JAPAN