Current Clamps
80i-110s
i30
i30s
i310s
i410
i1010
Specifications AC/DC Models
i30
Hall sensor
20 A AC RMS or DC
i30s
Hall sensor
20 A AC RMS or DC
30 A AC Peak
30 A AC Peak
Highest current
80i-110s
Hall sensor
10 A, AC/DC
100 A, AC/DC
0.1 A - 10 A AC/DC
1 A - 100 A AC/DC
140 A - 2 kHz
30 A AC Peak
30 A AC Peak
Lowest measurable current
Basic accuracy 1)
Useable frequency
Zero error adjustment
0.1 A
3% + 50 mA (@ 10 A)
DC - 100 kHz
O
Max. working voltage
Maximum conductor diameter
600 V
11.8 mm
50 mA
± 1% of reading ±2 mA
DC to 20 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm
50 mA
± 1% of reading ±2 mA
DC to 100 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm
Output level(s)
100 mV/A
10 mV/A
9 V, 55 h
1.6
100 mV/A
100 mV/A
10/1 mV/A
30 hours typical
1.5
O
n/a
n/a
CAT III, 300 V
30 hours typical
2
n/a
O
O
CAT III, 300 V
30 hours
2
Measurement type
Nominal current range(s),
Continuous current range
Battery, battery life
Output cable length (m)
Shrouded banana Plugs
BNC connector
BNC to banana adapter included
Safety
1)
O
CAT II, 600 V
CAT III, 300 V
i310s
AC/DC
30/300 A AC RMS
or 45/450 A DC
100 mA - 300 A AC
RMS or 450 A DC
300 A AC RMS or
450 A DC
100 mA
±1% of reading
DC to 20 kHz
Manual
i410
Hall sensor
400 A, AC/DC
400 A
i1010
Hall sensor
600 A, AC
1000 A, DC
1 A - 600 A, AC
1 A - 1000 A, DC
1000 A
0.5 A
3.5% + 0.5 A
DC - 3 kHz
O
0.5 A
2% +0.5 A
DC - 10 kHz
O
600 V
30 mm
2 x 25 mm
1 mV/A
600 V
30 mm
2 x 25 mm
1 mV/A
9 V, 60 h
1.6
O
9 V, 60 h
1.6
O
CAT III, 600 V
CAT III, 600 V
1 A - 400 A AC/DC
300 V AC RMS or DC
19 mm
O
O
CAT III 300 V
Basic Accuracy: % reading + floorspec
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
O
O
2
O
O
O
2
2
2
2
2
2
2
2
2
2
2
O
O
O
O
O
2
O
O
O
O
O
O
O
O
O
O
O
O
3
O
O
O
3
O
O
O
3
O
O
O
O
O
3
3
O
O
O
3
3
O
O
O
3
3
O
O
O
O
O
O
O
2
O
3
O
O
3
O
O
O
789
4
2
O
O
O
O
O
787
O
O
O
2
741B/743B/744
O
O
O
2
725
O
O
O
2
724
88V
O
O
O
2
715
83V/87V
O
O
O
2
1577/1587
77 IV
O
O
O
2
190 Series/215C/225C
8808A
O
O
O
2
4
O
125
8845A/8846
O
O
O
2
123/124
27II / 28II
O
O
O
2
430 Series
287/289
2
O
O
O
2
43B
233
• Combination of current clamp with
carrying case
• Zipped soft case with moveable
divider
• Soft case is large enough to hold a
meter
187/189
i410 Kit AC/DC Current Clamp
(400A) with soft case
i1010 Kit AC/DC Current Clamp
(1000A) with soft case
AC Models
i5s
i200
i200s
i400
i400s
i430 flex
i800
i1000s
i2000 flex (new version)
i3000s
i3000s flex
i6000s flex
AC/DC Models
i30
i30s
80i-110s
i310s
i410 / i410 kit
i1010 / i1010 kit
Other
90i-610s*
175/177/179
113/114/115/116/117
Current Clamp Compatibility Chart
O
O
O
2
O
O
O
2
O
2
O
O
O
O
O
2
O
O
O
O
O
O
2
O
O
O
2
O
O
O
2
O
O
O
2
2
2
O
2
O
2
O
O
O
O
2
O
O
O
O
O
O
O
O
O
O
1
1
1
1
1
1
* For specifications of 90i-610s see page 113
1 For DC only
2 Requires PM 9081 (see page 76)
3 Requires PM 9082 (see page 76)
4 115, 117 only
All accessories have a one year warranty
115