Installation Manual for installing the GTO/PRO SW-3200 with the GTO/PRO SW-3000 in a dual application DC-SERIES ® DC-SERIES ® FOR PROFESSIONAL INSTALLATION ONLY! WARNING! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value. READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times. All automatic gate operators are intended for use on vehicular gates only. 3121 Hartsfield Road • Tallahassee, Florida, USA 32303 Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 580-8816 or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850) 575-8950 www.gtopro.com rev - 02/12/06 R3200INST This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc. 2002 GTO, Inc. © The GTO/PRO® 3000/3200 Gate Operators are intended for use with vehicular swing gates. The operators can be used in Class I, Class II, Class III and Class IV applications. VEHICULAR GATE OPERATOR CLASS CATEGORIES Residential Vehicular Gate Operator-Class I: A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith. Commercial/General Access Vehicular Gate Operator-Class II: A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public. Industrial/Limited Access Vehicular Gate Operator–Class III: A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. Restricted Access Vehicular Gate Operator–Class IV: A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. Conversion Chart Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol centimeters meters kilograms 0.3937 3.2808 2.2046 inches feet pounds in. (or ") ft. (or ') lb. (or #) Converting English Units to Metric Equivalents When You Know Multiply By To Find Symbol inches feet pounds 2.5400 0.3048 0.4535 centimeters meters kilograms cm m kg Converting Temperature deg. Celsius deg. Fahrenheit (ºC x 1.8) + 32 deg. Fahrenheit (ºF-32) ÷ 1.8 deg. Celsius ºF ºC FOR YOUR RECORDS Please record the product serial number (located on the control box cover), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate operator. Serial Number ____________________ Date of Purchase ____________________ Place of Purchase ____________________ Remember to keep all receipts for proof of purchase. Table of Contents Gate Operator Class Categories ------------------------------------------------------------inside cover Units and Standards Conversion Chart ---------------------------------------------------inside cover PLEASE READ THIS FIRST! --------------------------------------------------page iii Important Safety Instructions -------------------------------------------------- page 1 KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Disconnecting the Operator -----------------------------------------------------------page 1 Important Safety Instructions for the Consumer ------------------------------------page 2 Secondary Means of Protection Against Entrapment ------------------------------page 5 Required Safety Precautions for Gates-----------------------------------------------page 6 Warning Signs and Labels -------------------------------------------------------------page 7 Installation -------------------------------------------------------------------------- page 8 Parts List ---------------------------------------------------------------------------------page 8 Technical Specifications -------------------------------------------------------------page 11 Installation Overview ---------------------------------------------------------------- page 12 Installation of the Mounting Hardware ----------------------------------------------page 13 Mounting the First Operator -----------------------------------------------------------page 17 Installing the Second Operator --------------------------------------------------------page 17 Installation of the Closed Position Stops --------------------------------------------page 18 Mounting the Control Box -------------------------------------------------------------page 20 Connecting the Operator Power Cables ----------------------------------------------page 21 Powering the System -------------------------------------------------------------- page 22 Solar Chart -------------------------------------------------------------------------------page 22 Connecting the Transformer -----------------------------------------------------------page 23 Control Board Settings ----------------------------------------------------------page 25 Main DIP Switches ---------------------------------------------------------------------page 25 Dual Mode DIP Switches --------------------------------------------------------------page 26 Setting Closed Position Limits --------------------------------------------------------page 27 Setting Your Personal Transmitter Code ---------------------------------------------page 28 Obstruction Sensitivity -----------------------------------------------------------------page 29 Installing the Receiver ----------------------------------------------------------- page 29 Connecting Additional Safety Devices ----------------------------------------page 30 Connecting Accessories ---------------------------------------------------------- page 32 Push to Open Installation -------------------------------------------------------- page 33 Setting Open Position Limits ----------------------------------------------------------page 34 Maintenance & Troubleshooting Guide -------------------------------------- page 36 Repair Service ---------------------------------------------------------------------page 38 Column Installation Information ---------------------------------------------- page 39 Accessory Catalog ---------------------------------------------------------------- page 40 DC-SERIES ® DC-SERIES ® PLEASE READ THIS FIRST! Thank you for purchasing the GTO/PRO® 3000/3200 gate operator system. When correctly installed and properly used, your GTO/PRO® 3000/3200 Operators will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your GTO/PRO® 3000/3200 Automatic Gate Operators. The GTO/PRO® 3000/3200 Operators are designed for installation on a pull-to-open dual leaf gates (gates that open into the property). By purchasing an accessory bracket, the GTO/PRO® 3000/3200 Operators can accommodate push-to-open dual leaf gates (gates that open out from the property). The gates must not exceed 16 feet in length (per leaf) nor weigh more than 650 pounds (per leaf) (please see Technical Specifications on page 11). The GTO/PRO® 3000/3200 Operators can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct and stop. The GTO/PRO® 3000/3200 Operators accommodate extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the enclosed GTO/PRO® Accessory Catalog) are available. The GTO/PRO® 3000/3200 Operators feature adjustable obstruction sensing. This safety feature makes the gates stop and reverse direction within 2 seconds when they come in contact with an obstruction. MIN is the factory setting; meaning the gates will exert the minimum force on an obstruction before they stop and reverse direction. The GTO/PRO® 3000/3200 Operators also have an adjustable auto-close feature. After the gates reache the fully open position, they can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gates open fully will cause them to close immediately. OFF is the factory setting; meaning the gates will stay open until you press the transmitter (or keypad, etc.) again. Please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/PRO® professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/PRO® dealer near you. BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR: Read these instructions carefully and completely to become familiar with all parts and installation steps. You must read the installation manual for detailed instructions on gate operator safety and proper use of the gate operator. iii IMPORTANT SAFETY INSTRUCTIONS Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety. This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT. Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the operator or its components, serious injury, or death. Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use. To Manually Open and Close the Gate, Follow the Procedure Below: CAUTION: The gate will move freely and uncontrolled when the gate operator is remove from the gate. ONLY disconnect the operator when the control box power switch is OFF and the gate is NOT moving. Front or Rear Mount Disconnecting the Operator 1. 2. 3. Turn control box power switch OFF. Remove hairpin clip, clevis pin, and bushing from either the front or rear mounting point. Remove the opener from the mount. Clevis Pin Gate Bracket The gate can be opened and closed manually when the operator is disconnected. Bushing Hairpin Clip NOTE: Substitute a Pin Lock for the clevis pin on the front mount of the gate operator to prevent unauthorized removal of the operator from the gate (see Accessory Catalog). 1 IMPORTANT SAFETY INSTRUCTIONS For The Consumer WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible. 2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion. 3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas. 4. The gate and gate operator installation must comply with any applicable local codes. I. Before Installation 1. Verify the operators are proper for the type and size of gate, its frequency of use and the proper class rating. 2. Make sure the dual gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used with the system. 3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation (see page 1). 4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for pedestrian use (see page 6). 5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE. 6. Pay close attention to the diagram below and be aware of these areas at all times. ZONE 1 ZONE 2 ZONE 5 ZONE 4 Gate in the Open Position ZONE 2 ZONE 3 ZONE 3 Driveway Entrapment Zones For a Pull-To-Open Application 2 ZONE 5 ZONE 4 Gate in the Open Position IMPORTANT SAFETY INSTRUCTIONS Entrapment Zones for a proper Pull-To-Open installation: Zone 1 – leading edge of the gate and the fence post. Zone 2 – between the gate and the gate post. Zone 3 – the path of the gate. Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc. Zone 5 – pinch points between the opener and gate or post. II. During Installation 1. Install the gate operator on the inside of the property and fence line. DO NOT install an operator on the outside of the gate where the public has access to it. 2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched. 3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment. 4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). Never install any control device where a user will be tempted to reach through the gate to activate the gate operator. 5. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement. 6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate. Pull-To-Open Application 10' 10' 10' Moving Gate Area 10' Moving Gate Area Driveway 10' NEVER INSTALL any control device within gray area 3 10' IMPORTANT SAFETY INSTRUCTIONS III. After Installation 1. Attach the warning signs (included) to each side of the gate to alert the public of automatic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements. 2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary. 3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop. 4. Do not attempt to "beat the gate" while the gate is closing. This is extremely dangerous. 5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them. 6. KEEP GATES PROPERLY MAINTAINED. Always turn power to operator OFF before performing any maintenance. Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month. 7. Service the gate and gate operator regularly. Grease hinges, spray push pull tube with high quality silicon spray and replace the battery every 3-5 years. 8. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (see page 1). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO Service Department. 9. Disconnect the operator ONLY when the power is TURNED OFF and the gate is NOT moving. 10. Make arrangements with local fire and law enforcement for emergency access. 11. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all persons authorized to use your gate. 12. IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate and gate operator are aware of the dangers associated with automated gates. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner. Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO/PRO® website (www.gtopro.com), by contacting GTO, Inc., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge. 4 IMPORTANT SAFETY INSTRUCTIONS Secondary Means of Protection Against Entrapment As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. The GTO/PRO® 3000/3200 utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the GTO/PRO® 3000/3200 has provisions for the connection of Type B2 protection to be used as the secondary type of entrapment protection, if desired. 1. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]): A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system. B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. Leading Edge Contact Sensor on both sides of the gate Vehicular Gate Vehicular Gate Post Edge Contact Sensor on both sides of the gate Bottom Edge Contact Sensor on both sides of the gate Post Edge Contact Sensor on both sides of the gate ENTRAPMENT ALARM (UL 325; 30A.1.1A) The GTO/PRO® 3000/3200 Operatosr are designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hardwired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm. 5 IMPORTANT SAFETY INSTRUCTIONS Required Safety Precautions for Gates Install Warning Signs Warning signs alert people of automatic gate operation and are required when installing the GTO/PRO® 3000/3200 Operators. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate. We recommend using the GTO Bulldog® Pedestrian Gate Lock (Call the GTO Sales Department) for controlled access. Bulldog Pedestrian Gate Lock (recommended, not included) Warning Sign Pedestrian Gate Contact Sensor (recommended, not included) Vehicular Gate Contact Sensor Vehicular Gate Contact Sensor (recommended, not included) Warning Sign (recommended, not included) Contact Sensor (recommended, not included) Entrapment Protection GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment. ! WARNING Warning Signs The warning signs (at right) must be installed on both sides of the gates (see page 7 for details). Moving Gate Can Cause Injury Or Death 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. 6 IMPORTANT SAFETY INSTRUCTIONS ! These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements. DC SW-3000 SERIES C LIS TED #xxxxxxx US Conforms to UL 325 STANDARDS Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.8 m) Voltage: 12 Vdc; Frequency: 0 Hz; Power: 40 W Class I, II, III and IV Vehicular Swing Gate Operator. Serial Number: XXXXXXXXXX TO MANUALLY OPEN AND CLOSE THE GATE: 1. Turn control box power switch OFF. 2. Disconnect front or rear mount from gate bracket. 3. Pull operator away from front or real mounts. Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving. GTO, Inc. Tallahassee, Florida USA Product identification and manual operation instruction label (1) installed on control box cover Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate) ! DC-SERIES WARNING MOVING GATE ® Can Cause Injury or Death 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use separate entrance. 1-800-543-GATE (4283) • www.gtopro.com Logo and warning labels (2) installed on each side of operator housing. ! DC-SERIES WARNING MOVING GATE ® Can Cause Injury or Death 1-800-543-GATE (4283) • www.gtopro.com 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use separate entrance. Logo and warning labels (2) installed on each side of operator housing. 7 SW-3000 Parts List ! WARNING Receiver (1) GTO Transmitter(1) Moving Gate Can Cause Injury Or Death FF ON/O 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. Warning Signs (2) Battery (1) Control Box (1) Transformer (1) Gate Operator (1) w/ 6' Power Cable Gate Bracket (1) Closed Position Stop Plate (1) ® ER EN TE OP E-Z GA Post Bracket (2) Post Pivot Bracket (1) Customer Support Card (1) Hardware 3/8" x 8" Bolt (4) 3/8" Washer (9) 3/8" x 3" Bolt (2) 3/8" Lock Washer (7) 3/8" x 2" Bolt (1) 2" Receiver Mounting Screw (5) 8" Nylon Cable Tie (14) 3/8" Bushings (2) 5/16" x 1-3/4" Bolt (1) 3/8" x 1-1/4" Clevis Pin (2) Hairpin Clip (2) 8 5/16" Washer (1) 3/8" Nut (7) 5/16" Nut (1) SW-3200 Parts List ! WARNING Moving Gate Can Cause Injury Or Death Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. Gate Operator (1) w/ 40' Power Cable Closed Position Stop Plate (1) Post Bracket (2) Post Pivot Bracket (1) Hardware 3/8" x 8" Bolt (4) 3/8" Washer (9) 3/8" x 3" Bolt (2) 3/8" Lock Washer (7) 3/8" x 2" Bolt (1) 5/16" Washer (1) 5/16" x 1-3/4" Bolt (1) 2" Mounting Screw (5) 8" Nylon Cable Tie (10) KEEP CLEAR! Gate may move at any time. 2. Warning Signs (2) 3/8" Bushings (2) Gate Bracket (1) 1. 3/8" x 1-1/4" Clevis Pin (2) Hairpin Clip (2) 9 3/8" Nut (7) 5/16" Nut (1) Other Materials You May Need Before You Start the Installation: Depending on the type of gate and fence post, you may need some additional materials/hardware. Some of these items can be found in the GTO/PRO Accessory Catalog. • Low voltage wire may be needed. Length depends upon the distance between the transformer power supply and the control box. See page 22, Powering the System and the Accessory Catalog for wire and solar charging panels. • If the gate is more than 1000' away from an AC power source you will need to use at least one GTO Solar Panel to trickle charge the battery. See the Accessory Catalog. • The diameter of the fence post should be at least 8" (round) or 6" (square) in order to mount the post bracket (see page 14). • Depending upon the diameter of the fence post, you may need longer carriage bolts than those provided. Bolts should be at least 1" longer than the diameter of the fence post (see page 14). • A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate. See page 13. Tools Needed • Power Drill • Open End Wrenches — 3/8", 7/16", 1/2", and 9/16" • 3/8" Drill Bit • Hacksaw or Heavy Duty Bolt Cutters • Small (Flat Bladed) Screwdriver • Phillips Screwdriver • Tape Measure • Level • Wire Strippers • C-Clamps — small, medium, and large • Center Punch • Extra person will be helpful 10 Technical Specifications GTO/PRO® 3200 OPERATOR GTO/PRO® 3000/3200 AUTOMATIC GATE OPERATOR DRIVE • Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-28 ºC to +71 ºC). Use of heater bans on arm and control box will enhance performance in extreme cold temperatures. • Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. Generates 820 ft.. lb. of torque at 12 V. • Maximum opening arc of 110º. Approximate opening time (90º): 20 seconds, depending on weight of gate. POWER • The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery. • Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc (40 VA) through the GTO control board. Blade-style control board fuse is rated for 25 A. NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board. • Battery charge is maintained by GTO Solar Panel Charger: float voltage of 14.5 Vdc output from a 193/8" x 81/2" silicon alloy panel. Generates minimum of 5 W at 300 mA. A gated diode on the control board prevents battery discharge. CONTROL • GTO microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog). • Control board has temperature compensated circuits. • A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 3 to 7 A. • Auto-memorization of digital transmitter code. • GTO remote-mounted RF receiver tuned to 318 MHz. • Operator length with push-pull tube fully retracted is 401/4", mounting point to mounting point. • Adjustable auto-close timer (OFF to 120 s), and obstruction sensitivity. • Power terminal bock accommodates a transformer and solar panels. • DIP switches simplify setup of gate operator. • Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, etc. • Control board allows connection of safety edge sensors and photoelectric sensors. • Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing. OPERATIONAL CAPACITY • The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 3000/3200 Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation. GTO/PRO® 3000/3200 Gate Capacity Chart Gate Length Estimated number of daily cycles are based on use with a transformer and one(1) 12 Volt battery on a dual gate system. 16 ft. 14 ft. 12 ft. up to10 ft. 80 85 90 95 50 lb. 75 80 85 90 100 lb. 70 65 75 70 80 75 85 80 150 lb. 200 lb. Gate Weight 60 65 70 75 300 lb. 55 60 65 70 400 lb. 50 55 60 65 500 lb. 45 50 55 60 650 lb. NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB. To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed on page 20 or call (800) 543-1236 or (850) 575-4144 for more information. * An operation cycle is one full opening and closing of the gate. These specifications are subject to change without notice. 11 Installation Overview Pull-to-Open Gates (Gate Opens into the Property) The diagram shown below is an example of a pull-to-open installation on a chain link fence and dual gates. Mounting the operators on a masonry column requires special procedures; see Column Installation Information on page 39 if you intend to mount the operators on columns. Furthermore, if you have push-to-open gates, you will need to purchase two (2) pushto-open brackets (see Accessory Catalog) to properly configure your system. See Push to Open Installation on page 33 before proceeding. Receiver Control Box with Battery 120 Volt Indoor Transformer (surge protector not supplied) Gate Swings Evenly and Freely Hung Firmly and Plumb SLAVE Gate Opener Post Bracket Assembly MASTER Gate Opener Gate Bracket Closed Position Positive Stop Plates 4 1/2' Power Cable Run 1000' (max.) of low voltage wire to control box from transformer (wire not included). PVC conduit (not included) to protect second opener power cable and low voltage wire from lawn mowers and weed eaters. Concrete Poured Around Gate Post Preparation of the Gate Step 1 The gates must be plumb, level, and swing freely on their hinges. Wheels must not be attached to the gates. The gates must move throughout their arc without binding or dragging on the ground. Note that gates over 250 lb. should have ball bearing hinges with grease fittings. Horizontal Cross Member Step 2 The fence posts must be secured in the ground with concrete so they will minimize twist or flex when the operators are activated. We recommend you position the operators near the centerline of the gates to keep the gates from twisting and flexing. The addition of horizontal or vertical cross members (if they are not already in place) to provide a stable area for mounting the gate brackets is also important. Vertical Cross Member 12 Installation of Mounting Hardware The position of the post bracket determines the leverage and efficiency of the operator. The post bracket position also sets the clearance between the operator and gate in the open and closed positions (minimum 2 inches). The curved design of the post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active operator, bolts that completely penetrate the fence post must be used. On wooden posts, place a metal plate or washer (not supplied) between the nuts and the fence post to prevent the thrust of the operator from pulling the bolts and washers out of the wood. Wooden Post Metal Plate Wooden Post Metal Plate NOTE: A fence post smaller than 6" in diameter or 6" square should be made of metal instead of wood so that it will remain stable while the operator is moving the gate. Post Bracket Post Bracket Post Pivot Bracket Post Pivot Bracket Larger than 6" diameter post Center of Gate Hinge On round posts of 6" diameter or larger, the post pivot bracket may not be necessary for the installation. In this instance, the two post brackets are mounted by themselves. Pull-to-Open Installation IMPORTANT: We strongly recommend using steel pipe, wood or metal to reinforce thin walled tube gates or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the operator and gate when the operator is installed. Recommended Reinforcement Examples Steel Pipe Cut in Half (not supplied) Gate Bracket Gate Bracket Panel Gate Thin Walled Tube Gate Wood or Metal Reinforcement (not supplied) 13 Gate Bracket 1" x 6" Wood Reinforcement Determining the Mounting Position of the Post Bracket Assembly and the Gate Bracket Post Bracket Assembly Step 3 Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a 3/8" lock washer, 3/8" washer and 3/8" nut on the end of the bolt. DO NOT overtighten the nut because the post pivot bracket will have to be adjusted later. 3/8" x 2" Bolt Post Bracket Post Pivot Bracket Post Bracket 3/8" Washer NOTE: The following steps are intended for pull-to-open gate installations. If you are mounting your operators on a push-to-open gate (e.g., a gate on a sloped driveway) you will need to purchase two Push To Open brackets (see Accessory catalog). Also, see Pushto-Open Installation beginning on page 33. 3/8" Lock Washer 3/8" Nut Step 4 Attach post bracket assembly and gate bracket to the operator with the clevis pins and bushings. Secure the clevis pins with hairpin clips. Clevis Pin Front Mount Rear Mount Clevis Pin Bushing Gate Bracket Operator Bushing Hairpin Clip Post Bracket Assembly Hairpin Clip Step 5 With the gate in the open position (up to 110º from its closed position) and the operator fully retracted, adjust the post bracket assembly and gate bracket until the operator is level. While holding the operator level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. Post Bracket Assembly Level Operator LEVEL hori zontal cro ss Gate In Open Position Fence Post 14 member Gate Bracket IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. Step 6 When you feel that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate operator, swing the gate and gate operator to the closed position. With the gate and gate operator in the closed position check the clearance and be sure that the gate operator is not binding at the post pivot bracket. If you don't have 2 inches of clearance or the gate operator is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances. With the post pivot bracket in the optimum position for clearance and freedom of movement, reattach the operator to the gate bracket in the open position and recheck the gate operator level and make sure the brackets are clamped securely. 2" minimum Gate in the CLOSED POSITION Pinch Area Be sure gate opener and bracket don't bind. Pinch Area Gate in the OPENED POSITION 2" minimum TIP: Turning the pivot bracket over gives more hole alignment options for the post pivot bracket assembly. You can also move the entire post pivot bracket assembly to different positions on the gate post to help achieve the proper clearances. 15 Installing the Post Bracket Assembly and Gate Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post bracket assembly and gate bracket. After marking your reference points, remove the operator and brackets from the fence and gate. EXAMPLES Mark fence post through TOP VIEW middle of bracket slots Step 8 and drill 3/8" holes Drill 3/8" holes into fence post as marked. Round Metal Post Step 9 Fasten post bracket assembly to the fence post using (4) 3/8" x 8" bolts, washers, lock washers, and nuts (provided). Remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters. Square Metal Post SIDE VIEW Post Bracket Assembly Square Wood Post NOTE: In cases where the fence post has a diameter larger than 6", threaded rods or carriage bolts longer than 8" (not supplied) must be used. Remove excess bolt length with hacksaw or bolt cutters Round Wood Post Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. Drill 3/8" holes into the gate cross member as marked. Gate In Open Position Mount gate bracket using (2) 3/8" x 3" bolts, washers, lock washers, and nuts (provided). Cut off excess bolt length extending beyond the tightened nuts. LEVEL ho rizontal cr oss member Mark cross member through middle of gate bracket slots and drill 3/8" holes Gate Bracket Mounting Examples FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW Mounting Plate Created for Decorative Gate (required but not supplied) Round Tube & Chain Link Gate Remove excess bolt length with hacksaw or bolt cutters Square Tube Gate 16 Mounting the First Operator Step 11 Attach the operator to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Locks (see Accessory Catalog). Verify that the operator is level and adjust the post bracket assembly if necessary. Post Bracket Assembly bolted to fence post Level Operator LEVEL hori zontal cros sm ember Gate Bracket bolted to gate cross member Clevis Pin, Bushing and Hairpin Clip Fence Post Gate In Open Position Clevis Pin, Bushing, and Hairpin Clip Installing the Second Operator Step 12 Install the SLAVE operator on the remaining gate leaf by repeating Step 3 through Step 11, starting on page 14. After you have mounted the SLAVE operator, proceed to Installing the Closed Position Stops on the next page. 17 Installation of the Closed Position Stops The GTO/PRO® 3000/3200 Gate Operators firmly hold the gates in the closed position using positive stops. The positive stops help stabilize the gate leaves in the closed position. To further enhance stability and security, we strongly recommended using an optional GTO/PRO® Automatic Gate Lock (see Accessory Catalog) with your dual gate. IMPORTANT: You need to determine which side of the driveway you will mount the control box. From this point on the gate and gate operator on the same side as the control box will be referred to as the MASTER gate and gate operator. The gate and gate operator on the opposite side of the driveway from the control box will be referred to as the SLAVE gate and gate operator. Optional Ground Stop (beneath gate) Gate Hinge MASTER GATE SLAVE GATE Closed Position Stop Plates CONTROL BOX The gate leaf can open up to 110˚ (max.) The gate leaf can open up to 110˚ (max.) Illustration A Step 1 Closed Position Stop Plate mounted horizontally on metal post with U-bolts. Attach the horizontal closed position stop plate to the MASTER gate leaf. Detach the gate operators from the gates and move the gates to their closed position (Illustration A). Using appropriate hardware for your type of gate (U-bolts for tube or chain link; screw or bolts for wood or metal) attach the closed position stop plate (horizontally) about mid height on the MASTER gate frame. Do not tighten it completely at this time. Slide the stop plate toward the frame of the SLAVE gate leaf until they touch (Illustration B). Once you have moved the stop plate to the correct position, tighten its hardware completely. Gate Hinge FRONT VIEW SLAVE Gate Frame MASTER Gate Frame Illustration B TOP VIEW NOTE: The optional ground stop post is used to provide a secure point for the SLAVE gate to close against. If you will be using the GTO/PRO Horizontal Gate Lock accessory with your gate operator system, the closed position ground stop is REQUIRED, as shown in Steps 2 and 3 on the next page. 18 Step 2 Install a low profile ground stop (not provided) beneath the SLAVE gate stop plate. Closed Position Stop Plate mounted on the gate leaf that CLOSES FIRST Mount Vertically The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground (we recommend setting it in concrete). Illustration C SIDE VIEW Closed Position Stop Plate Low Profile Ground Stop in Near the Center of Driveway FRONT VIEW Step 3 Attach a vertical closed position stop plate to the SLAVE gate. Using appropriate hardware for your type of gate attach the vertical closed position stop plate to the SLAVE gate frame at the point where it will come in contact with the ground stop post.. Do not tighten it completely at this time. You must slide the closed position stop plate toward the ground stop until they touch (Illustration C). Once you have moved the stop plate to the correct position, tighten its hardware completely. NOTE: For a push-to-open installation (gate opens out from the property) attach the closed position stop plate to the outside of the gate. At this stage of the installation, the operators should be installed on the gate leaves and closed position stops should be in place. SLAVE Gate Opener Post Bracket Assembly MASTER Gate Opener ® 1-800-543-GATE (4283) www.mightymule.com Gate Bracket Closed Position Positive Stop Plates 19 OPTIONAL Closed Position Ground Stop Post Mounting the Control Box Step 1 Mount the control box using the screws (provided) or another secure mounting method. The control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical interference. 15 Use mounting holes and screws provided to mount control box to a secure surface. ON DUAL ON MODES 1 www.gtoinc.com 2 3 4 OFF SET LIMIT 1 2 3 4 5 6 7 ON MODES ON 1 2 3 4 5 6 7 OFF LEARN TRANSMITTER 12' SWITCH 14' 10' 8' 16' BRN ORG SLAVE INPUTS RED BLK GRN WHT BLUE BRN ORG MASTER INPUTS RED BLK COM COM SAFETY GRN WHT BLUE OPEN EDGE – + NC RLY-COM NO SOLAR RELAY OUT CLOSE EDGE ~ ~ 18VAC SHADOW LOOP GATE LENGTH CYCLE CLOSE 3000, MUST be placed in the top (horizontal) battery slot with the terminals on the RIGHT. The extra (vertical) battery slot is for an optional second battery. An optional second battery can be used for solar and/or high traffic applications, if needed.. 1 2 3 4 BAT– BAT+ 800-543-GATE GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 EXIT/ OPEN NOTE: The battery that came with your GTO/PRO® ALARM FUSE SWITCH GRN BLK RED RECEIVER Step 2 Make sure the control box power switch is in the OFF position. The ON/OFF Switch is located on the bottom of the control box. Remove the control box cover and slide the battery into position with its terminals to the RIGHT (see illustration). Connect the BLACK battery wire to the NEGATIVE (–) battery terminal. Connect the RED battery wire to the POSITIVE (+) terminal. Pay close attention to the color of the wires. If the wires are connected incorrectly, the control board will be damaged. NEVER insert the battery with the terminals to the left. BLACK wire to NEGATIVE (—) terminal RED wire to POSITIVE (+) terminal BLACK RED 12 V Battery (Included) Step 3 Strain Relief Strip approximately 3/16" of insulation from each wire of the power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place. 15 ALARM FUSE 1 2 3 4 BAT– GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 ON DUAL ON MODES BAT+ SWITCH 800-543-GATE 1 www.gtoinc.com 2 3 4 OFF SET LIMIT 1 2 3 4 5 6 7 ON MODES ON 1 2 3 4 5 6 7 OFF LEARN TRANSMITTER 12' SWITCH 14' 10' 8' 16' BLK GRN WHT BLUE BRN ORG MASTER INPUTS RED BLK COM COM OPEN EDGE SLAVE INPUTS RED SAFETY BRN ORG CLOSE EDGE GRN WHT BLUE EXIT/ OPEN – + NC RLY-COM NO SOLAR RELAY OUT CYCLE CLOSE ~ ~ 18VAC SHADOW LOOP GATE LENGTH GRN BLK RED RECEIVER Lock Nut Hub Sealing Nut Strain Relief Operator Power Cable Single Battery Installed Horizontally with terminals on the right. NOTE: The battery that came with your GTO/PRO® 3000 , Dual Batteries Installed Vertically with terminals on bottom. MUST be placed horizontally battery with the terminals on the RIGHT. If an optional second battery is needed, both batteries must be placed vertically with terminals at the bottom. An optional second battery can be used for solar and/or high traffic applications, if needed.. 20 Connecting Operator Power Cables MASTER Operator Step 4 J13 BLUE BRN ORG RED MASTER INPUTS J5 BLK COM J11 COM CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP Wrong J8 Wrong WHT Power cable from MASTER operator arm Tighten the set screws against the end of the wires. A dab of petroleum jelly on each terminal will help prevent corrosion. Correct SWITCH GRN Insert the stripped power cable wires into the appropriate terminals on the MASTER OPERATOR terminal block. The green wire should be inserted into the GRN terminal, the blue wire into BLU, the orange wire into ORG, black wire into BLK, and the red wire into the RED terminal. CLOSE EDGE OPEN EDGE STALL FORCE MAX Wire J12 Terminal Block RED Wire BLK RECEIVER Terminal Block GRN Wire MIN Terminal Block SLAVE Operator Step 5 Review the Installation Overview illustration on page 12 before proceeding. Cut a slot into the driveway to accommodate PVC conduit (not provided). The buried conduit will protect the 40 foot power cable from automobile tires, lawn mower blades, weed eaters, and grazing animals. Pull the 40 foot second operator power cable through the conduit and secure them into the slot in the driveway. Step 6 Strip approximately 3/16" of insulation from each wire of the 40 foot power cable. Twist each exposed wire tightly. Insert the second operator power cable upward through the right strain relief (if necessary, loosen the sealing nut). Thread approximately 4" of wire into the control box. Retighten strain relief (on the black sheath of the power cable) until the power cable locks into place. Power Cable from the SLAVE operator arm GRN WHT J6 BLUE BRN ORG BLK J21 RED SLAVE INPUTS SWITCH GRN Insert the stripped wires of the power cable into the appropriate terminals on the SLAVE OPERATOR terminal block. The green wire should be inserted into the GRN terminal, the blue wire into BLU, the orange wire into ORG, black wire into BLK, and the red wire into the RED terminal. BRN ORG RED J5 BLK 21 J13 BLUE MASTER INPUTS WHT Tighten the set screws against the end of the wires. Powering the System Installation of the Transformer IMPORTANT: • The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used. • All low voltage wire used with the GTO/PRO® 300/3200® Gate Operator must be 16 gauge dual conductor, multi-stranded, direct burial wire (see page 23 and the Accessory Catalog). Do not run more than 1000 feet of wire. • If your gate is more than 1000 ft. from an ac power source, you will need to use from 10 to 30 watts of solar charging power to charge the battery (see Accessory Catalog). Refer to the Solar Panel and Gate Activity chart below. OPTIONAL Solar Panel and Gate Activity Winter Ratings The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar charging power. (see Accessory Catalog). The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. Accessories connected to your system will draw additional power from the battery. 12 v dual gate (10 watts) solar charger 12 v dual gate (15 watts) solar charger 12 v dual gate (20 watts) solar charger 12 v dual gate (25 watts) solar charger 12 v dual gate (30 watts) solar charger Zone 1 8 11 14 17 20 Zone 2 Zone 3 16 20 28 36 44 26 30 38 46 54 NOTE: A maximum of 30 watts of solar charging power can be connected to the GTO/PRO® 3000/3200 Gate Opener. Consult Solar Panel Installation Instructions for further information. Step 1 Make sure the power switch is OFF before proceeding to the next step. FF ON/O ON/OFF Switch Step 2 Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. After you have measured how much wire is needed, cut the wire to the appropriate length. (Not more than a 1,000 feet). 22 IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft. DO NOT use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are inadequate for use with your gate operator system. Telephone wire and solid core wire do not deliver enough voltage for your gate operator to function and will cause the system to go into a condition known as "low voltage lockout." NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current. 12 V Battery Step 3 Lay the measured length of low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench. 15 ALARM FUSE 1 2 3 4 BAT– 800-543-GATE GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 1 www.gtoinc.com Step 4 ON DUAL ON MODES BAT+ SWITCH 2 3 4 OFF SET LIMIT 1 2 3 4 5 6 7 ON MODES ON 1 2 3 4 5 6 7 OFF LEARN TRANSMITTER Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires. 14' 10' 8' 16' SLAVE INPUTS BLK GRN WHT BLUE BRN ORG MASTER INPUTS RED BLK COM COM EXIT/ OPEN RED SHADOW LOOP BRN ORG OPEN EDGE GRN WHT BLUE CLOSE EDGE – + NC RLY-COM NO SOLAR RELAY OUT SAFETY ~ ~ 18VAC CYCLE CLOSE GATE LENGTH Low Voltage Wire from Transformer or Solar Panel WARNING! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7!! 12' SWITCH GRN BLK RED RECEIVER Strain Relief Operator Power Cable PVC Pipe Step 5 J9 GRN Insert one transformer wire into an 18VAC terminal. Insert the other transformer wire into the remaining 18VAC terminal. The transformer wires can be connected to the 18VAC terminals regardless of color. J2 Low Voltage Wire from AC Transformer J1 RED BLACK ~ ~ + NC RLY-COM NO 18 VAC SOLAR RELAY OUT Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the 18VAC terminals located on the POWER IN terminal block (see illustration at right). Be certain not to let the exposed wires touch each other! WHT J6 BLUE BRN ORG BLK J21 RED SLAVE INPUTS SWITCH GRN BLUE BRN ORG RED BLK J5 23 J13 MASTER INPUTS WHT Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion. Step 6 Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals. A dab of household petroleum jelly on each terminal will help prevent corrosion. Transformer Step 7 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board. 24 SURGE PROTECTOR Make sure the exposed wires do not touch each other! CONTROL BOARD SETTINGS DIP Switches Main DIP Switch Settings (MODES) DIP Switch #1 - Soft Start/Stop The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate operator system. 1 2 3 4 5 6 7 ON ON 1 2 DIP Switch #2 - Warning Buzzer The Warning Buzzer alerts you when the gate operator is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning. 5 6 7 OFF ON ON OFF OFF* ON OFF ON OFF* 15 seconds 30 seconds 60 seconds 120 seconds (factory preset) DIP#5 D1 mode, constant pressure to operate gate. ON OFF* B2 mode, momentary contact to operate gate. DIP#4 ON Push-to-open operation. OFF* Pull-to-open operation. DIP#3 ON Auto-close enabled. OFF* Auto-close disabled. DIP Switch #4 - Push/Pull-to-Open If your gate opens into the property the DIP Switch is set to OFF (factory). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need a Push-to-Open bracket (see Push-to-Open Instructions on page 30). DIP Switches #6 and #7 The combination of these two switches determines the amount of time the gate will remain open when DIP Switch #3 is set in the ON position. 4 DIP#6 DIP#7 Delay Time for Auto-Close DIP Switch #3 - Auto-Close With the Auto-Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter, keypad, or push button control. With the Auto-Close switch in the ON position the gate operator will automatically close the gate, if the gate is in it's open limit position. The time the gate will remain open is determined using DIP Switches #6 and #7. DIP Switch #5 - B2/D1 Mode This DIP Switch must remain in the OFF position unless the gate operator is going to be used by a guard or gate attendant, who can only open the gate when constant pressure is applied to a push button control device. 3 DIP#2 ON* Buzzer warning enabled. OFF Buzzer warning disabled DIP#1 ON* Soft start enabled. OFF Soft start disabled. * Factory Preset. IMPORTANT CONTROL BOARD SETTINGS: CONTROL BOARD DIP SWITCH #1 is factory preset in the ON position and MUST remain in the ON position. Changing this setting can damage your gate, gate opener and possibly void your warranty! 25 Dual Gate DIP Switch Settings (DUAL MODES) DIP Switches #1 and #2 (Factory Set OFF/OFF) The combination of DIP Switches #1 and #2 will determine the sequence dual gates will open and close. #1 OFF, #2 ON and #3 OFF 1 2 3 4 1 2 3 4 DUAL ON MODES 1 2 3 4 #1 OFF, #2 ON and #3 ON 1 2 3 4 DUAL ON MODES 1 2 3 4 ON OFF ON OFF ON OFF ON * 1 2 3 4 DUAL ON MODES 1 2 3 4 #1 ON, #2 OFF and #3 ON OFF DUAL ON MODES 1 2 3 4 ON OFF 1 2 3 4 DUAL ON MODES 4 #1 ON , #2 OFF and #3 OFF OFF 3 1 2 3 4 ON 2 OFF 1 2 3 4 DUAL ON MODES 1 7 #1 OFF & #2 OFF SET LIMIT 6 DIP Switch #4 - Used to set MASTER and SLAVE gate closed position limits (next section). #4 ON = when setting closed limit for SLAVE gate. #4 OFF = when setting closed limit for MASTER gate. 1 2 3 4 5 6 7 ON ON DIP Switch #3 - Additional Delay (Factory Set OFF) To add 4 seconds to the standard 4 seconds, a total of 8 seconds delay, sequence delay switch to ON. Set Limit Button Factory setting. Single Arm (Master Only) operation. Dual Mode DIP Switches MASTER gate starts to open 2 seconds before SLAVE gate / SLAVE gate starts to close 4 seconds before MASTER gate. MASTER gate starts to open 2 seconds before SLAVE gate / SLAVE gate starts to close 8 seconds before MASTER gate. MASTER and SLAVE gates open simultaneously / SLAVE gate starts to close 4 seconds before MASTER gate. MASTER and SLAVE gates open simultaneously / SLAVE gate starts to close 8 seconds before MASTER gate. * REQUIRED SETTING for use with GTO/PRO Horizontal Gate Lock accessory. 1 2 3 4 DUAL ON MODES 1 2 3 4 ON 1 2 3 4 DUAL ON MODES #4 OFF to set or CLEAR MASTER Position Limit 1 2 3 4 OFF 26 ON OFF #4 ON to set or CLEAR SLAVE Position Limit Setting the Closed Position Limits TURN CONTROL BOX ON Your GTO/PRO® 3000/3200 has two Limit Settings 1) OPEN Limit setting: (Gate in the OPEN POSITION / FACTORY SET NOT ADJUSTABLE) The open limit setting is the fully open position. 2) CLOSED Limit setting: (Gate in the CLOSED POSITION) To achieve optimum closed position, you are required to complete the following SEVEN STEPS: Step 1 Confirm that the power switch is in the ON position, and the gates are in the OPEN POSITIONS. Step 2 Activate your operators by pressing the entry transmitter button. Your gates should now be moving from the fully open positions toward their closing position. Prepare to STOP gate by pressing the entry transmitter button again when the first gate reaches the desired closed position. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 3. Step 3 With the first gate in the desired closed position. Program the closed limit setting by setting the number 4 DIP switch on the DUAL MODES switches to the OFF position (if the MASTER gate closed first) or the ON position (if the SLAVE gate closed first) then PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds. Step 4 Press the transmitter button and allow the gates to return to the fully open position. YOUR FIRST GATE’S CLOSED POSITION LIMIT IS NOW PROGRAMMED. Step 5 Activate your operators again by pressing the entry transmitter button. Your gates should now be moving from the fully open positions toward their closing position. The first gate will stop at the spot you just programmed and the second gate will continue to close until you press the transmitter button again. The optimum CLOSED POSITION for the second gate is when it closes firmly, without excess tension, against the first gate. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 6. Step 6 With the second gate in the desired closed position. Program the closed limit setting by setting the number 4 DIP switch on the DUAL MODES switches to the ON position (if the MASTER gate closed first) or the OFF position (if the SLAVE gate closed first) then PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds. COM J11 COM CYCLE CLOSE SAFETY J8 EXIT OPEN SHADOW LOOP 2 3 4 5 ON OFF 6 7 OFF MAX 27 1 2 3 4 1 4 SET LIMIT 3 Set Limit Button DUAL ON MODES 2 RED 1 2 3 4 5 6 7 ON 1 STALL FORCE J12 BLK RECEIVER GRN MIN LEARN TRANSMITTER OPEN EDGE MODES ON CLOSE EDGE Step 7 Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SLAVE GATE’S CLOSED POSITION LIMITS ARE NOW PROGRAMMED. TESTING YOUR CLOSED LIMIT SETTING: Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again. CLEARING PROGRAMMED CLOSED LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their fully opened positions, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit Setting Your Personal Transmitter Code All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO/PRO® 3200 Gate Operator®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below: 1. Remove the Transmitter Cover Grasp the sides of the access cover and slide it away from the transmitter button (see illustration). When the access cover is removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches. 2. Set the transmitter DIP Switches There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, –). DO NOT set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been set to a personal code, replace and close the access cover. WARNING: No other adjustments should be made inside the transmitter. 3. “Teach” the New Code to Control Board Memory COM J11 COM A. Press and hold transmitter button. B. Press and hold the LEARN TRANSMITTER button on the control board for 5 seconds. C. Release transmitter button. D. Release LEARN TRANSMITTER button. The new code is stored in control board memory. CYCLE CLOSE SAFETY J8 EXIT OPEN SHADOW LOOP 2 3 4 5 1 2 3 4 1 DUAL ON MODES SET LIMIT 4 ON OFF 6 7 OFF 1 2 3 4 5 6 7 ON 3 MAX 28 2 Learn Transmitter Button 1 RED STALL FORCE J12 BLK RECEIVER GRN MIN LEARN TRANSMITTER OPEN EDGE MODES ON CLOSE EDGE Obstruction Sensitivity Potentiometer IMPORTANT: For safety reasons the obstruction setting or Stall Force on the Mighty Mule® control board comes from the factory set at MIN (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates. 1 2 3 4 DUAL ON MODES 1 TThe Stall Force potentiometer on the control board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the opener will apply to an obstruction) before it automatically stops and reverses direction for approximately two (2) seconds. 2 3 4 ON OFF SET LIMIT 1 2 3 4 5 6 7 ON MODES ON 1 2 3 4 5 6 7 OFF LEARN TRANSMITTER STALL FORCE MAX OPEN EDGE J12 CLOSE EDGE EXIT OPEN COM CYCLE CLOSE COM SHADOW LOOP J8 J11 SAFETY MIN MAX Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position where the gate operates without obstructing from its own weight or the wind conditions in your area. MIN STALL FORCE GRN BLK RED RECEIVER NOTE: You may need to increase the stall force in cold weather due to increased resistance from gate hinges. ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPENER! Installing the Receiver Use the transmitter to check the range of the receiver before permanently mounting it. Consider the following when mounting the receiver: • Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the GTO Sales Department). NEVER splice receiver cable! • Run the cable through PVC conduit to protect it from damage. • DO NOT run cable through metal conduit because the receiver signal range will be decreased. • DO NOT run cable in conduit containing ac wiring. • DO NOT mount receiver on a metal fence or post; doing so will decrease signal range. • The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference. • DO NOT mount upside down. FCC Regulation This device complies with FCC rules Part 15. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept an interference that may cause undesired operation. Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. 29 Connecting Additional Safety Devices Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with any applicable UL standards (United Laboratories) and national and regional safety codes. Call GTO Sales at 1-800-543-4283 for information on compatible products for your specific application. The GTO/PRO® 3000/3200 will ONLY accept accessory devices with normally open contact output. Contact Sensors (safety edges) If not installing a contact sensor skip to next section. PLEASE NOTE: Contact sensors are not included with the GTO/PRO® 3000/3200. The GTO/PRO® 3000/3200 is equipped with built-in obstruction sensitivity. The operator is designed to stop and reverse the gate within 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, although functioning properly, may not be sensitive enough to prevent bodily injury in some circumstances. To augment your protection against entrapment, GTO recommends using some form of additional safety device. When installed, contact sensors must be mounted in compliance with UL 325, Underwriters Laboratories safety standard for gate operators. Review page 5 for information about mounting requirements for safety edges ("contact sensors"). Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate. STALL FORCE MIN MAX OPEN EDGE J12 CLOSE EDGE SAFETY COM CYCLE CLOSE COM EXIT OPEN J8 J11 SHADOW LOOP Make sure the power switch to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF. GRN BLK RED RECEIVER Contact Sensor Input Connection: Connect one of the OPEN EDGE contact sensor wires to the COMMON (COM) terminal and the other to the OPEN EDGE terminal on the GTO/PRO®3000/3200 control board. Connect one of the CLOSE EDGE contact sensor wires to the COMMON (COM) terminal and the other to the CLOSE EDGE terminal on the GTO/PRO® 3000/3200 control board. Wire from Contact Sensor (open safety edge) Wire from Contact Sensor (close safety edge) Activation of a contact sensor while the gate is in motion will cause the gate to stop and reverse within 2 seconds. 30 Non-Contact Sensors (photo beams) If not installing a non-contact sensor skip to next section. PLEASE NOTE: Non-contact sensors are not included with the GTO/PRO® 3000/3200 . The GTO/PRO® 3000/3200 can also accept "Safety" input from normally open "dry-contact" output devices such as photo beams connected to the SAFETY input terminal. Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate. MIN J8 OPEN EDGE CLOSE EDGE EXIT OPEN COM J12 SHADOW LOOP COM Connect one of the non-contact sensor dry contact output wires to the COMMON (COM) terminal and the other to the SAFETY terminal on the GTO/PRO® 3000/3200 control board. SAFETY J11 CYCLE CLOSE Non-Contact Sensor Connection: MAX Make sure the power switch to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF. STALL FORCE GRN BLK RED RECEIVER This input is ONLY monitored when the gate is closing. Activating the non-contact sensor (obstructing the safety beam path) will cause the gate to reverse to the fully open position. Wire from Non-Contact Sensor (photo beam) Shadow Loop If not installing a shadow loop skip to next section. PLEASE NOTE: Non-contact sensors are not included with the GTO/PRO® 3000/3200 . STALL FORCE MIN OPEN EDGE J12 CLOSE EDGE SHADOW LOOP EXIT OPEN COM SAFETY COM Shadow Loop Connection: J8 J11 CYCLE CLOSE Make sure the power to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF. MAX Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate. GRN BLK RED RECEIVER Connect one of the shadow loop wires to the COMMON terminal and the other to the SHADOW LOOP terminal on the GTO/ PRO® 3000/3200 control board. The SHADOW LOOP is a detector located with the moving path of the gate to prevent the gate from closing when a vehicle in the path. Wire from Shadow Loop 31 Connecting Accessories If not connecting accessories skip to next section. The GTO/PRO® 3000/3200 can accept NORMALLY OPEN CONTACT accessories, such as; Push Button Entry Devices and Key Pads. Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate. Make sure the power to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF. STALL FORCE MIN MAX Accessory Input Connection: Each activation of the accessory will cause the gate to cycle as follows: OPEN STOP CLOSE OPEN EDGE CLOSE EDGE SHADOW LOOP COM EXIT OPEN COM J12 J8 SAFETY J11 CYCLE CLOSE Connect one of the accessory wires to the COMMON (COM) terminal and the other to the CYCLE CLOSE terminal on the GTO/PRO® 3000/3200 control board. GRN BLK RED RECEIVER STOP Wire from Accessory (push button, key pad, etc.) Output Relay The output relay provides N/O and N/C contact. N/O contact functions only when gate is moving. N/C contact functions only when gate is at rest. Relay can switch up to 36 volts A/C or D/C and can be used for strobe type warning lights, to turn on safety beams, etc. 32 Push to Open Installation Swinging gates shall not open into public access areas! A "Push-to-Open" gate opens out from the property. A Push-to-Open Bracket is required for this type of installation (see Accessory Catalog). If you have a pull-to-open gate (gate opens into the property), return to page 14; step 3. In a PUSH-TO-OPEN installation the operators are installed while the gates are in the closed position. Step 1 With the gates closed, adjust the post bracket assembly and the gate bracket until the operator is level. While holding the operator level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. Post Bracket Assembly Determining The Mounting Position of The Post Bracket Assembly 3/8" x 2" Bolt Post Bracket Push-To-Open Bracket (optional accessory) Post Bracket 3/8" Washer 3/8" Lock Washer 3/8" Nut IMPORTANT: While determining the mounting point for the post pivot bracket assembly be sure that the position allows for maximum clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. Step 2 Gate in the Open Position Pinch Area (gray) After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4" bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5/16" washer and nut. Two inch minimum IMPORTANT: If you loosened the clamp on the post bracket to achieve the optimum position, tighten it in its new position and recheck the gate bracket with the gate in the open position (move the gate bracket and re-clamp it if necessary). Gate in the Closed Position Pinch Area (gray) Two inch minimum 33 Step 3 With the gate in the fully closed position and the operator retracted, swing the operator to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The operator must be level. (Some vertical adjustment is possible by sliding the post bracket assembly up and down.) Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the operator to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips. Fence Post LEVEL Gate Post and Gate Cross Member (In Closed Position) Operato r LEVEL POST PIVOT BRACKET level with the horizontal surface of the GATE BRACKET LEVE L Step 4 1 2 3 4 5 6 7 ON ON 5 6 7 OFF Install the second gate operator on the other gate in the same manner. Then refer to the CONTROL BOARD SETTINGS on page 26 for gate sequencing and other programming steps before proceeding. COM COM CYCLE CLOSE Step 5 OPEN EDGE 4 EXIT OPEN 3 CLOSE EDGE 2 SHADOW LOOP 1 SAFETY Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 4 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open. GRN BLK DIP#4 ON Push-to-open operation. OFF Pull-to-open operation (factory setting). Setting the Open Position Limit In a PUSH-TO-OPEN Installation Your GTO/PRO® 3200 has two Limit Settings 1) CLOSED Limit setting: (Gates in the CLOSED POSITION / FACTORY SET NOT ADJUSTABLE) The closed limit setting in the closed position. 2) OPEN Limit setting: (Gates in the OPEN POSITION) To achieve optimum open position, you are required to complete the following SEVEN STEPS: Step 1 Confirm that the power switch is in the ON position, and the gates are in the CLOSED POSITIONS. Step 2 Activate your operators by pressing the entry transmitter button. Your gates should now be moving from the closed positions toward their open position. Prepare to STOP gates by pressing the entry transmitter button again when the first gate reaches the desired open position. This step may be repeated until desired close position is achieved. Once the desired OPEN position has been achieved, proceed to step 3. 34 RED RECEIVER Step 3 • IF the MASTER gate was the first gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES switches on the control board to the OFF position. Then press and hold the SET LIMIT button for five seconds. • IF the SLAVE gate was the first gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES switches to the ON position. Then press and hold the SET LIMIT button for five seconds. Step 4 1 2 3 4 DUAL ON MODES 1 Step 5 2 3 4 DUAL ON MODES ON 1 4 ON OFF 1 2 3 4 5 6 7 ON MODES ON 1 2 3 4 5 6 7 OFF LEARN TRANSMITTER STALL FORCE MIN MAX EXIT OPEN CYCLE CLOSE COM SAFETY COM SHADOW LOOP J8 J11 • IF the MASTER gate was the second gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES switches on the control board to the OFF position. Then press and hold the SET LIMIT button for five seconds. 3 SET LIMIT Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the closed positions toward their open positions. The first gate will stop at the spot you just programmed and the second gate will continue to open until you press the transmitter button again. Press the transmitter button when the second gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to step 6. Step 6 2 OFF J12 OPEN EDGE 1 2 3 4 CLOSE EDGE Press the transmitter button and allow the gates to return to the closed position. YOUR FIRST GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED. GRN BLK RED RECEIVER • IF the SLAVE gate was the second gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES switches to the ON position. Then press and hold the SET LIMIT button for five seconds. Step 7 Press the transmitter button and allow the gates to return to the closed position. BOTH YOUR MASTER AND SLAVE GATE’S OPEN POSITION LIMITS ARE NOW PROGRAMMED. TESTING YOUR OPEN LIMIT SETTING: Press your entry transmitter and allow your gates to open. If OPEN positions are not correct or need to be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again. CLEARING THE PROGRAMMED OPEN LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their closed positions, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the open limit positions. Follow steps one (1) to seven (7) again. 35 Maintenance & Troubleshooting If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department. • On all gates weighing 250 lb. or more, routinely grease the ball bearing hinges at least 4 times a year; more frequently if the gates are near a coastal area. • Keeping a few mothballs in the control box will discourage insects from entering it and damaging the control board. • Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month. • While oxidation is a normal part of weathering of equipment that is exposed to the elements, we recommend you apply silicone spray the front and rear mounts to minimize this effect. If the Operator Does Not Work Check the Green LED on the Control Board: IF THE LED IS OFF: This condition indicates a transformer power failure. 1. Test the transformer for voltage with a voltmeter. The acceptable range can be found in the VOLTAGE LIMITS chart on the next page. If the transformer test shows no voltage, then test the electrical outlet for voltage. If the outlet test shows voltage, then the transformer is dead and must be replaced. Allow the new transformer 12 hours to charge the battery before using the gate operator. 2. If the transformer test shows voltage, check the POWER IN terminal block on the control board for voltage. If the terminal block shows no voltage, look for broken or spliced wires. Check the Red STATUS LED on the Control Board: IF THE LED IS ON: but the unit is not working. 1. Check the battery in your transmitter and replace with a fresh one if needed.. 2. Verify that the power cable is securely connected. 3. Replace the control board fuse if it is blown (25 ampere fuse only - DO NOT USE A HIGHER RATED FUSE!). IF THE LED IS OFF: 1. Make sure the ON / OFF switch at the bottom of the control box is set to ON. 2. Check all connections for looseness and corrosion. 36 If the Operator is Working The Gate CLOSES Then Opens Again on its Own: 1. Check the position of the mounting brackets and readjust if necessary. 2. Check the gate for binding or hinge damage. 3. Check the position of the stroke adjustment knob. The Gate OPENS Then Closes Again on its Own: 1. Check the position of the mounting brackets and readjust if necessary. 2. Check the gate for binding or hinge damage. 3. Check the position of the stroke adjustment knob. VOLTAGE RATINGS 18 Vac Transformer ___________________________ 18.0 to 22.0 Vac 5 W Solar panel (single) _______________________18.0 to 22.0 Vdc 300 mA measure voltage at panel and control box. 12 V Battery ________________________________12.0 to 13.5 Vdc 7.0 Ah Charging circuit _____________________________12.0 to 14.8 Vdc measure voltage with battery connected The GTO, Inc. Technical Service Department is open Monday – Friday 8:00 A.M. – 5:00 P.M. (Eastern Time) Telephone (800) 543-1236 Telephone (850) 575-4144 37 Repair Service If your GTO/PRO® 3200 Automatic Gate Operator is not operating properly, please follow the steps below: 1. First use the procedures found in the Maintenance & Troubleshooting Guide (see page 35). 2. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the control box cover) and date of purchase when calling for assistance. 3. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you. 4. Securely pack the component(s) authorized for return to the factory. Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT. Ship the package(s) freight prepaid to: GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA 32303. NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO freight collect WILL NOT be accepted. ® PROFESSIONAL ACCESS SYSTEMS Fax (850) 575-8950 • Web site: www.gtopro.com E-Mail: [email protected] 38 Column Installation Information IF THIS OPERATOR WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS: A. The simplest solution is to install the operator in a push-to-open configuration (requires Push-To-Open Bracket, see Accessory Catalog). The minimum clearance is easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength. B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the columns. C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is NOT for the inexperienced! Column Mount Example (A + B can not exceed 14 inches) Example: If A is 2" then B can not exceed 12" A Pivot Bracket B Gate Column Hinge 39 DC-SERIES ® DC-SERIES ® ACCESSORIES Solar Panel (FM123), (FM122) The Solar Panel is a 10 watt solar powered battery charger for use with the all GTO/PRO DC gate operator systems. Particularly suited for remote installations, each Solar Panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire). The GTO/PRO® control board has clearly labeled terminal connections for easy installation of the Solar Panel. Installation in some regions of the world will require multiple solar panels for adequate charging power. Solar Panel (FM122) is a 5 watt solar powered battery charger with all the same features as (FM123). Push Button Control (RB101) Unlit doorbell button for remote entry or exit control. Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately). Pin Lock (RB975) The Pin Lock substitutes for the clevis pin at the front end of the GTO/PRO® 1500 gate operator. Helps prevent theft of the operator from the gate, while allowing quick release of the operator. Key Chain Mini Transmitter (RB744) The Key Chain Mini Transmitter is a miniature version of the GTO/PRO® entry transmitter and has the same adjustable code settings. 12 Volt battery included. Entry Transmitter (RB741) The GTO/PRO® entry transmitter, with adjustable code settings, is standard equipment with all GTO/PRO® systems. 9 Volt battery included. 2 1 7 3 ABC 4 GHI PRS DEF 5 6 JKL MNO 8 9 TUV WXY 0 Digital Keypad (F300) The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to fifteen different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Wired installations require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold separately). Requires 3 AA batteries (not included). GTO/PRO 50' Exit Wand (FM139), 100' Exit Wand (FM140), 150' Exit Wand (FM141) The GTO/PRO® Exit Wand is designed for residential and agricultural applications and is compatible with all GTO/PRO® automatic gate operator models. The wand is an electromagnetic sensor, which offers 'hands free' operation of the GTO/PRO® Gate Operators with a 12 ft. radius of detection of vehicles in motion. ATIC® CKK TOM LOLOC AUTE ITY GASEC UR IC ON 9V Wireless Entry Intercom / Keypad (FM136) Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. Codes can be permanent of temporary. Can be wireless or hard wired up to 1000 feet. AC DV CE 3 SS 1-8 CO 00 NT -54 RO 3-4L SY 28 ST EM S Ans wer Per Grant mis sio n Key Ba pad tt Low POW ER CTR ELE Automatic Gate Lock Pull-to-Open (FM144) A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks automatically as gates open and close. Used with GTO/PRO® DC swing gate operating systems for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas. 40 Accessories (con't) Replacement Battery (RB500) Standard 12 volt, 7.0 amp-hour, maintenance-free battery for the GTO/PRO® 2000, GTO/PRO® 3000, GTO/ PRO® 4000 gate operator systems. This is the only battery approved for use with the GTO/PRO® gate operator systems. Life expectancy is 3-5 years. Low Voltage Wire (RB509) The 16 gauge, multi-stranded, dual conductor Low Voltage Wire is for connecting the AC powered transformer, or the Solar Panel to the control board. Also used for the connection of accessories, such as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV treated, PVC coated and ready for direct burial. Push to Open Bracket (347IH) Required when GTO/PRO® 3000/3200 gate operator(s) must push the gate open, such as on a sloping driveway or where space prevents gate(s) from opening inward (pulled open). Order two PTO brackets for conversion of a dual swing gate installation. Column Mount Lock Receiver (433IH) For mounting the Automatic Gate Lock on brick columns, walls, or for other applications with limited space between gate and post. Replacement Transformer (RB570) Standard 18 volt AC transformer for maintaining the battery included with the GTO/PRO® 3000 gate operator. This is the only transformer approved for use with all UL325 GTO/PRO® gate operator systems. HEDDOL RECUNIV ERSAL F MOD EL EIVE 294 R Garage Door Receiver (RB709) The Garage Door Receiver allows you to use the same GTO/PRO® entry transmitter (see Dual and Triple Transmitters) to operate your gate operator and your garage door operator. Compatible with most garage door operators. Dual & Triple Button Transmitters (RB742 & RB743) The Dual (RB742) & Triple (RB743) Button Transmitters are for remote control of multiple separate gate operators, and/or gate operator(s) and garage door operator(s) (see Garage Door Receiver). 9 Volt battery included. If you have a question about any accessory, just call 1-800-543-GATE! The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law. GTO®, GTO/PRO®, Bulldog® are registered trademarks of GTO, Inc. Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”). All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO. 41