• Zoom-To zoom the image, use the bar to scroll through the percentage values. Select OK. Use the Pan tool if the image is larger than the window area on the Analyze screen. Check Show Advanced Features to adjust Threshold, Range, Black/White Controls, or Image Type and to reset contrast. • Threshold-To adjust the threshold, select the Threshold option and either move the vertical lines that are shown on the bone profile, enter values in the black/white fields, or adjust the Brightness/Contrast controls. Select OK. • Range-To adjust the range, select the Range option and either move the vertical lines that are shown on the bone profile or enter values in the black/white fields. Select OK. • Black/White-Enter a value in the Black and White fields. Select OK. • Type-Click the drop down menu and choose between the following image types: Enhanced Bone, Tissue, and Unfiltered Bone. Select OK. • Reset Contrast-Select Reset Contrast to reset settings. Select OK. Use the tools given in the following table to magnify an image during analysis. These tools are shown on the Analyze screen: Icon Tool Description Reset Mode Select to deactivate the Zoom and Pan Image tools. Zoom Image Move the cursor over the image and use the Zoom Image tool to activate mouse control to zoom in or out on the image. If you zoom the image larger than the viewable area on the screen, use the Pan Image tool to view hidden areas of the image. Select the Pan Image tool, then drag the cursor to move the image. Move the cursor over the image and use the Zoom Image bar to zoom in or out on the image. Pan Image Zoom Image 4.1.3 Advanced: Adjust ROIs ROIs do not need to be adjusted in most circumstances. The procedures for adjusting ROI position are specific to each measurement site. Caution: Some ROI adjustments will render the results unreliable. See the specific scan type recommendations for analysis. 4.1.4 Advanced: Adjust Point Typing 1 enCORE analysis automatically assigns point typing to a scan and usually requires no adjustment. Significant changes to Point Typing will affect both the results and reproducibility of a scan. The procedures that follow give instructions to examine and adjust point typing for an image (only Artifact point typing can be adjusted for Total Body analysis). DO NOT adjust the point typing unless the program has made obvious errors. Change the point typing only if the area that needs to be changed is larger than the default cursor size. It is recommended that changes be limited to Bone and Neutral point typing. 1 A tool that lets you 1) view how the program classified the sample points, and 2) change the classification if necessary. The point typing determines the placement of bone edges. Page 62 of 138