Download MF RD700 Command Set User & Reference Manual

Transcript
Philips Semiconductors
User Manual Rev. 3.0 June 2005
Command Set
MF RD 700
3.1 Administration Command Set
The Administration Command Set covers several Commands for reader IC administration and configuration.
3.1.1 INCLUDED FUNCTIONS
Function name
Function call
PCDReset
signed char PcdReset (void)
PCDSetTmo
signed char PcdSetTmo (unsigned long numberOfEtus)
PCDGetSnr
signed char PcdGetSnr (unsigned char *snr)
PCDGetRICVersion
signed char PcdGetRICVersion(unsigned char* version)
PCDReadE2
signed char PcdReadE2 (unsigned short startaddr,
unsigned char length,
unsigned char *data)
signed char PcdWriteE2 (unsigned short startaddr,
unsigned char length,
unsigned char *data)
signed char PcdRfReset (unsigned short ms
PCDWriteE2
PCDRFReset
Table 3-2. Administration Commands
Note: In case of an error, the appropriate error code is set. Nevertheless, all received data are returned.
This feature helps to debug the errors. Even if all data seems to be received correctly (data is filled up with
reasonable values), a CRC, parity or other error could be reported.
3.1.2 FUNCTION DESRIPTION
3.1.2.1 PcdGetRICVersion
signed char PcdGetRICVersion (unsigned char * version)
Cmd-Code: 0x64
IN
OUT version (5)
Parameters:
snr
(OUT) 5 bytes reader type ID
Returns:
MI_OK
The reader type ID depends on the current used reader IC. Please refer to the reader ICs data sheet.
12