PROGuard – User’s Manual Registering On altering an existing iButtons/TagRF it is possible to change its description. To delete a checkpoint, simply select it with the mouse and then click on 'Delete'. ‘Learn’ Button When clicked, the button 'learn' enables the Guardus itself to enter into a learning mode, redefining the current checkpoints or including new checkpoints. This procedure allows that all of the programming information, configured in whichever window up to that moment, be recorded, enabling also that all of the previously registered checkpoints be, or not, discarded. For this operation to proceed the data conformation is necessary as shown in the following window: If the button 'Yes' is clicked on, new checkpoints can be included, preserving the current ones. If the 'No' button is clicked on, all existing points will be discarded thus promoting a full reregistering of checkpoints. It is also possible to cancel the operation by clicking on 'Cancel'. The inclusion or reordering of new checkpoints can then be done by placing Guardus in contact with the communication interface. The sequence in which the readings are carried out must be the same as that in which the iButtons are registered. The reading of a master iButton/TagRF can result in the Guardus returning to normal operation. Confirmation of the exit of the learning mode is given through the emission of the signal for rounds carried out. Guardus will be ready to operate normally, considering the new checkpoints configuration. www.contronics.com 69