Download Operating level 2
Transcript
- Fault No. 11/12: Fa u l t N o . 11 se n s o r A 1 de f e c ti v e F a ul t N o. 1 2 For the distance controlled rejection sensors are used to determine the position. These monitor each other. If one transmitter is out of order, it will be displayed s en s o r A 2 d ef e c t iv e − Check the function by means of the LED-Display at the transmitter. − Check the function on the optional circuit board on the board AMD 02. − Check the function voltage supply of the sensors. If it is not possible to acknowledge - see page D1. - Fault No. 13: F a ul t N o. 1 3 fa u l t r e j ec t m ec h a n i cs The electronics AMD 02 monitor the reject process on metal detectors with a reject device. − Check if the sensor is fixed securely on the pneumatic cylinder (standard state LED on / Rejector LED out). − Check the power supply of the sensor − Check the function by means of LED on the sensor − Check the function by means of LED on the optional board. − Check if the reject duration is adjusted for too short a duration. If it is not possible to acknowledge - see page D1. C3/5