Download ADT917&918 User Manual

Transcript
Warnings and cautions
Be careful when using with small chamber or low pressure gauges
not over pressure the gauges.
Do not exceed 1500 psi for 917 ( 2000 psi for 918 ) safety limit.
Do not shift between pressure and vacuum mode while the pump is
under pressure. Open the vent valve as well as the bypass valve
before switching between vacuum and pressure modes.
Do not over tighten gauges or connectors. Lightly hand tight is sufficient.
Store the pump in a dry non-corrosive environment.
Additel is not responsible for problems or damage resulting from
improper use or operation of the equipment.
Specification
Pressure range: 917: 4 psi ( 0.95 bar ) vacuum to
1000 psi ( 70 bar ) positive pressure
918: 4 psi ( 0.95 bar ) vacuum to
1500 psi ( 105 bar ) positive pressure
917/918
Pneumatic Pressure Test Pump User's Manual
[Version number:1307V01]
Temperature:(0~50)℃
Humidity: < 85%RH
Fine adjust : 10 Pa ( 0.1 mbar )
Maximum pressure: 917: 1500 psi ( 105 bar )
918: 2000 psi ( 140 bar )
Pressure media: Air
Size: Height: 5.5'' ( 140 mm );
Base: 12.4'' ( 315 mm ) x 7.8'' ( 198 mm )
Weight: 5.7 lb ( 2.6 kg )
Remark:If local atmosphere pressure is 1 bar, the vacuum can reach to -0.95 bar;
If local atmosphere pressure is P, the vacuum can reach to - 0.95P.
Configuration & Air routine
1
1 - Pressure lever for pre-pressurization
2 - Handle
3 - 1/4 NPT plug
4 - Release valve
3
2
Air routine
7
3
(clockwise to close/ counterclockwise to open)
5 - Pressure lock
6 - Pressure/vacuum selector
(Pressure: pull it out; Vacuum: push it in
DO NOT switch under pressure or vacuum to
avoid damage)
!
65 4
7
7 - Isolation valve (Bypass valve)
4
6
1
(isolates the calibration from the one way valve)
8
Under Vacuu
8 - Fine adjustment handle
8
(clockwise to increase pressure)
Troubleshooting
Problems
Hard to use pressure lever
Hard to pressurize
Hard to use fine
adjustment handle
Fittings do not turn into
pump easily
Solutions
Causes
The isolation valve is not open.
Open the isolation valve.
A. Release valve is not closed.
Close the release valve.
B. The sealing ring is broken or loosen.
Replace sealing ring.
C. P/V selector is in wrong position.
Pressure: pull it out; Vacuum: push it in.
A. The isolation valve is not closed.
Close the isolation valve.
B. The gauges is not tightened.
Tighten the reference gauge or the gauge under test.
C. The sealing ring is aged or frayed.
Replace sealing ring.
D. The connector type is unmatched.
Use the right and suitable adapter.
E. Particle is blocking the air route.
Pressurize and release pressure quickly several time to try and blow the particle out.
Disassembly and cleaning may be necessary.
A. Likely tightened too much!
Do not apply too much force to close the fittings and gauges.
B. The new pump is not smooth.
The new pump needs time to abrade.
C. The threads have no lubrication.
Lubricate the threads.
Basic Operation
Connection
A
DIGITAL PRESSURE
CALIBRATOR
Units
A
0
25
50
75
100
SW
SW
V
mA
COM
V
mA
COM
24V
24V
Pressure Gauge
k
pressure switch
dial gauge
Open to atmosphere
Units
A
25
50
75
Pre-pressure
Zeroing should
be operated
under this
condition only.
DIGITAL PRESSURE
CALIBRATOR
0
B
pressure transmitter
flexible hose
Pressurizing process
and fine adjustment
C
DIGITAL PRESSURE
CALIBRATOR
D
DIGITAL PRESSURE
CALIBRATOR
Units
Units
A
100
0
25
50
75
A
100
0
Pressure Gauge
25
50
75
100
Pressure Gauge
Pressure Gauge
④ push down to
pre-pressurize
to desired value
or until hard to
push down
open
open
Decrease pressure process
use too
much
force
use too much
force
pressure position is shown.
push in for vacuum.
Please vent pressure before switch.
!
① close,do not
③ close,do not
② open
② pressurize to
① set it to the
higher pressure by
turning the handle and
make fine adjustment
mid position
of its travel
E
Vacuum process
F
Vacuum and
fine adjustment
DIGITAL PRESSURE
CALIBRATOR
DIGITAL PRESSURE
CALIBRATOR
Units
G
DIGITAL PRESSURE
CALIBRATOR
Units
Units
A
0
25
50
75
A
0
100
25
50
A
75
100
0
0.06
Pressure Gauge
0.08
- 0.1
⑤ operate it
0.04
25
50
75
100
0.06
Vacuum Gauge
0.02
0.08
0
- 0.1
0.04
Vacuum Gauge
0.02
0
to get the
desired
value
it slowly
① open
to get the
①open
desiredvalue,
and close!
④ close
② open
use too
much
force
③
push in,select the vacuum position
! make sure to complete the step ②
before operating step ③.
② fine adjustment
Decrease vacuum process
① close,do not
② fine adjustment
H
DIGITAL PRESSURE
CALIBRATOR
Units
A
0
25
50
75
100
0.06
0.08
0.02
- 0.1
① close
0.04
Vacuum Gauge
0
it slowly
② open
to get the
desired value,
and close!
Remarks:
A: Additel has made a concerted effort to provide complete and current
information for the proper use of this equipment. The product
specifications and other information contained in this manual are
subject to change without notice.
B: Above pictures are just for reference.
③ fine adjustmentt
Additel Corporation, USA
www.additel.com