Download Additel 914 Handheld Pneumatic Pressure Test Pump User Manual
Transcript
Warnings and cautions Low pressure gauges can very easily be over pressured if not careful. Please take caution when applying pressures. Do not exceed the safety pressure limit of 1000 psi (70bar). This pump is not designed to be used in explosive or corrosive environments. Do not switch between pressure and vacuum mode under pressure. Over tightening connectors may cause damage. Store the pump in dry and non-corrosive environments. Additel is not liable for any safety problems or damages caused by misuse or incorrect operation. All moisture and contaminants should be cleaned out of the liquid isolator before creating a vacuum. This is accomplished by venting the pump when at high pressure. For the least risk in contamination of the reference gauge, the DUT should be installed to the pressure port which is closest to the vent valve. Specification ADT914 Handheld Pneumatic Pressure Test Pump User's Manual [Version number:1409V12] Please download the latest version from www.additel.com Pressure range: 95% vacuum to 375 psi ( 25 bar ) Temperature: 0~50 ℃ Humidity: < 85%RH Adjusting fineness: 10 Pa ( 0.1 mbar ) Safety pressure: < 1000 psi ( 70 bar ) Pressure media: Air Size: Height: 5.12'' ( 130 mm ); Base: 9.45'' ( 240 mm ) x 4.72'' ( 120 mm ) Weight: 3.3 lb ( 1.5 kg ) Configuration & Air routine 2 1 3 4 1 - Quick connector Air routine 2 - Vent valve 3 (clockwise to close/ counterclockwise to open) 3 - Isolation valve (isolates the calibration volumn from pressurizing system) 4 - Hand pump 7 2 5 - Fine adjust handle (clockwise to increase pressure) 4 6 - Security bolt pin (use it to ensure safety) 7 6 5 7 - Pressure/vacuum (P/V) selector 5 (Postive pressure: pull it out; Vacuum: push it in) Troubleshooting Problem Solution Cause Hand pump will not generate pressure The isolation valve is not open. Open the isolation valve. A. Vent valve is not closed. Close the vent valve. It is difficult to increase pressure B. The O-ring seal is loose or damaged. Hard to use the fine adjust It is difficult to turn the quick connectors Replace the O-ring seal. C. P/V selector is in the wrong position. Pressure: pull the P/V selector out; Vacuum: push the P/V selector in. A. The isolation valve is not closed. Close the isolation valve. B. The gauges are not tightened. Tighten the reference gauge or the gauge under test. C. The O-ring seal is damaged. Replace the O-ring seal. D. The thread surface is not smooth. Use Teflon tape on the thread and turn it in tight. E. The connector is mismatched to the gauge pressure port. Use the correct adapter. F. Dust or contaminants are blocking the pressure flow Repeat pressurizing the pump several times and then suddenly vent which will push any contaminants out. A. Too much force was previously applied. Secure the quick connection with less force. B. The threads have no lubrication. Apply lubrication to the threads. O-Rings for pressure connector P/N Size Connector 1611300004 4X1.5 M10X1, 1/8BSP, 1/8NPT 1611300220 6.5X3 M20X1.5, 1/2BSP, 1/2NPT 1611300024 6X2 M14X1.5, 1/4BSP, 1/4NPT, 3/8BSP Basic Operation Connection A DIGITAL PRESSURE CALIBRATOR Units A 0 25 50 75 100 SW SW V mA COM V mA COM 24V 24V Pressure Gauge k pressure switch dial gauge Vent Zeroing should be operated under this condition only. B pressure transmitter Pre-pressure Increasing pressure and fine adjustment C Units Units A A A 0 25 50 75 D DIGITAL PRESSURE CALIBRATOR DIGITAL PRESSURE CALIBRATOR DIGITAL PRESSURE CALIBRATOR Units flexible hose 75 50 25 0 Pressure Gauge 100 Pressure Gauge 100 75 50 25 0 100 ⑤ push down to Pressure Gauge open pre-pressurize to desired value or until pressurization stops ① close, do not use too much force ④ close, do not use too much force ③ open it to the mid ② set position of its travel open to higher ② Pressurize pressure by turning the handle and make fine adjustments ① push the security bolt pin in Decreasing pressure E Vacuum pressures F Repeat Vacuum pressure DIGITAL PRESSURE CALIBRATOR DIGITAL PRESSURE CALIBRATOR DIGITAL PRESSURE CALIBRATOR Units Units A 0.06 A 0 25 50 75 Pressure Gauge 100 0 25 50 75 ② fine adjust pull out Units 0.04 A Vacuum Gauge 100 (0~6)MPa it slowly to get the desired ① open value, and close! G ② 08 0.02 - 0.1 0 0 pull up to achieve the ⑤ desired value 25 50 75 0.06 0.04 Vacuum Gauge 100 08 0.02 - 0.1 0 up to achieve ② pull desired value it must be open when ④ close(but select the pressure/vacuum) ① open ① open ③ push in to select the vacuum position Decreasing vacuum pressures H DIGITAL PRESSURE CALIBRATOR Units A 0.06 0.04 Vacuum Gauge 0 25 50 75 100 08 0.02 - 0.1 0 Remark: it slowly to get the desired ② open value, and close! ① close ③ fine adjust A: Additel has made a concerted effort to provide complete and current information for the proper use of the equipment. The product specifications and other information contained this manual are subject to change without notice. B: Above pictures are just for reference. Additel Corporation, USA www.additel.com