Download Caution
Transcript
Chapter 3 Printer Adjustments Chapter 3 Printer Adjustments Sensor Adjustments The sensing level of both the transparent (see thru) and reflective sensors is adjusted separately and independently. Firstly, the sensor type must be selected using the Sensor Method Selection shown below. Then the adjustment and calibration of the sensor can be made. Entering Sensor Adjustment Mode 1. Turn on the power while pushing the Pause key, Feed key, and Stop key simultaneously. MENU key Pause key Stop key Power Switch 2. After “Sensor Cal Mode” lights up, release the keys to change the printer to sensor adjustment setting mode. Sensor Cal Mode See Through Installing the Media (p.26) Sensor Selection Method (Transparent Reflective) To switch from transparent to reflective sensor, hold down the Feed key and then press the Stop key. Each time you press the Stop key, you switch to back and forth between the two sensor types. Sensor Cal Mode See Through Hold Press/Release If the transparent sensor is selected, “See Through” is displayed and the buzzer sounds once. If the reflective sensor is selected, “Reflect” is displayed and the buzzer sounds twice. 55