Download caution - Benshaw
Transcript
8 - Troubleshooting & Maintenance How to Check Power Components 8.7 How to Check Power Components Before checking the power components, be sure to disconnect AC Input supply and wait until the Main Electrolytic Capacitors (DCP-DCN) discharge. DCP Tr1 Charge resistor Contactor D1 D2 D3 R Electrolytic capacitors S T Tr5 Tr3 B1 G G G B2 E E E U V W + G E D4 D5 D6 DCN G G G E E E Current sensing resistor Tr4 Tr6 Tr2 1) Disconnect the power input line (R, S, T) and the drive output to the motor (U, V, W). 2) Verify whether the drive terminal R, S, T, U, V, W, B1,B2 is short or open by changing the polarity of the tester. 3) Verify that the capacitor has discharged before testing. 4) The tester should display several megaohms when open. The tester can display that the terminal is short for a short time and then display several megaohms because of the electrolytic capacitor. The tester should display several W ~ several tens W. If all measured values are almost the same the modules are without fault. 5) The number of each element of the module and the check terminal. Elements D1 Diode Module D2 D3 Tr1 IGBT Module Tr3 Tr5 154 Test Polarity + R B1 B1 R S B1 B1 S T B1 B1 T U B1 B1 U V B1 B1 V W B1 B1 W Measure Element d Value Open Short Open Short Open Short Open Short Open Short Open Short D4 D5 D6 Tr4 Tr6 Tr2 Test Polarity + R DCN DCN R S DCN DCN S T DCN DCN T U DCN DCN U V DCN DCN V W DCN DCN W Measure d Vlaue Short Open Short Open Short Open Short Open Short Open Short Open