Description of Function Codes MD280 User Manual details, see the output terminal functions described in group F3. When F0-01 is set to 4 (Multi-reference), set F8-00 and F8-08 to determine the required speeds. Function Code Parameter Name Setting Range Default 0: Set by F8-01 1: AI1 Reference 0 setting source F8-00 2: AI2 0 3: Pulse setting 4: PID 5: Preset frequency (F0-03) with UP/DOWN modification It is used to set the setting source of reference 0. Note that when F8-00 is set to 4, F6-00 (PID setting source) cannot be set to 4 (Multireference). Function Code Parameter Name Setting Range Default F8-01 Reference 0 -100.0%–100.0% 0.0% F8-02 Reference 1 -100.0%–100.0% 0.0% F8-03 Reference 2 -100.0%–100.0% 0.0% F8-04 Reference 3 -100.0%–100.0% 0.0% F8-05 Reference 4 -100.0%–100.0% 0.0% F8-06 Reference 5 -100.0%–100.0% 0.0% F8-07 Reference 6 -100.0%–100.0% 0.0% F8-08 Reference 7 -100.0%–100.0% 0.0% When F0-01 is set to 5 (PLC), you need to set the PLC running parameters F8-00 to F8-27. The negative/positive mark of values of F8-00 to F8-08 determines the simple PLC running direction: The positive mark indicates the forward direction, and the negative mark indicates the reverse direction. Figure 6-23 Simple PLC running Simple PLC running Acceleration /Deceleration time defined in F8-13 F8-07 F8-03 F8-08 F8-01 Acceleration /Deceleration time defined in F8-15 F8-02 F8-12 F8-14 Acceleration /Deceleration time defined in F8-17 DO, relay - 142 - 250 ms pulse signal