Download USERS MANUAL
Transcript
PT-R4300 USERS MANUAL 3. Enter the desired initial laser power (or zoom value) and then press [ENT]. The highlight will move to the left increment value setting. 4. Enter the desired increment value for the drum rpm (or focus value) and then press [ENT]. The highlight will move to the right increment value setting. 5. Enter the desired increment value for the laser power (or zoom value) and then press [ENT]. The highlight will move to the left count setting. 6. Enter the desired count for the drum rpm (or focus value) and then press [ENT]. The highlight will move to the right count setting. 7. Enter the desired count for the laser power (or zoom value) and then press [ENT]. The highlight will move to the exposure start point setting. NOTE If the initial value for the laser power is 50%, the increment is 10%, and the count is 5, and the initial value for the drum rpm (min-1) is 450, the increment is 50, and the count is 6, exposure will take place five times beginning at a laser power of 50% and incrementing by 10% to light intensities of 60%, 70%, 80%, and 90%, and then six times beginning at a drum rpm (min-1) of 450 and incrementing by 50 to drum rpm (min-1) of 500, 550, 600, 650, and 700. 8. Enter the exposure start point and then press [ENT]. NOTE • When performing a test exposure (simultaneous adjustment), the settings for the media type registered in the plate data that is selected when the plate is loaded are used for settings other than the initial value, increment value, and count (in the case of a laser power and drum rpm test exposure, the focus value and zoom value settings). • To set the initial value, increment value, count, and exposure start point, refer to “Table 5-1 Input ranges”, under “9.1 Test Exposures for Adjusting the Laser Power, Drum Rpm, Focus, and Zoom” and set the values while paying attention to the following points: • The initial value must be equal to or more than the minimum limit. • [Initial value + increment × (count - 1)] must be equal to or less than the maximum limit. • [Test exposure start point + 35 × (horizontal count - 1)] must be equal to or less than the horizontal size of the plate. • [Test exposure start point + 100 × (vertical count - 1)] must be equal to or less than [vertical size of plate - 40 mm]. 9. When entry is complete, press [OK]. The test exposure confirmation screen appears. (The confirmation screen for simultaneous adjustment of the laser power and drum rpm.) 2400dpi (700) (75.0) 650 rpm 50.0 % Initial: Incriment: 25 rpm 2.0 % Count: 9 10 Start Point: 0.0 mm CANCEL ESC START CANCEL Returns to the test exposure selection screen. Fig. 5-50 Test exposure (simultaneous adjustment) confirmation screen 5-38