Transcript
B-980 (0) ●Installation in Control Panel & Mounting Direction INSTRUCTION SHEET When installing the MicroSmart in a control panel, To crimp the ferrules shown below, use a special take the convenience of operation and maintenance, crimping tool (CRIMPFOX ZA 3). and FC5A Series ●Applicable Ferrule Dimensions (mm) resistance against environments into This sheet provides brief operating instructions of the MicroSmart programmable controller. For details, see the MicroSmart User’s Manual. (AI 1-8 RD、AI 1.5-8 BK) (AI-TWIN 2×0.75-8 GY) 20 mm minimum ( FC5A-C10R2, FC5A-C16R2, FC5A-C24R2 (AC power supply) FC5A-C10R2C, FC5A-C16R2C, FC5A-C24R2C (DC power supply) ) indicates the Type No. of Phoenix Contact. ●Recommended Screwdriver ●Name & Function Sensor Power Terminals (No support for DC power supply type.) For 1-cable connection For 2-cable connection consideration. 40mm minimum Input Terminals When wiring the Phoenix Contact terminal block, use 40mm minimum the recommended screwdriver. (Phoenix Contact Type No.: SZS 0.6×3.5) SAFETY NOTE Port 1 Expansion Connector Analog Potentiometer Special expertise is required to use the MicroSmart. 20 mm minimum • Read this instruction sheet and the user's manual to make sure of correct operation before starting installation, wiring, Port 2 Connector operation, maintenance, and inspection of the MicroSmart. Correct Mounting Direction (at 55℃ or below) Bottom View Power Supply Terminals Output Terminals Cartridge Connector Input LED Power LED (PWR) Run LED (RUN) Error LED (ERR) Status LED (STAT) Output LED Keep this instruction sheet at the end user. Allowable Mounting Direction at 35ºC or below Front Panel • All MicroSmart modules are manufactured under IDEC's rigorous quality control system, but users must add a backup 20 mm minimum or failsafe provision to the control system using the MicroSmart in applications where heavy damage or personal injury may be caused in case the MicroSmart should fail. 80mm minimum • Install the MicroSmart according to instructions described in Allowable Mounting Direction at 40ºC or below this instruction sheet and the user's manual. Improper installation will result in falling, failure, or malfunction of the MicroSmart. Terminal Cover • Make sure that the operating conditions are as described in 20 mm minimum the user’s manual. If you are uncertain about the Expansion Connector Seal Hinged Lid Wiring Duct specifications, contact IDEC in advance. Incorrect Mounting Direction • In this instruction sheet, safety precautions are categorized in order of importance to Warning and Caution: Front Cover Terminal Cover ●Dimensions ●Assembling Modules Remove the expansion connector Seal from the 24-I/O (Warning notices are used to emphasize that improper operation may cause severe personal injury or death.) FC5A-C24R2, C24R2C 95.0 •Turn power off to the MicroSmart before starting installation, 70.0 removal, wiring, maintenance, and inspection on the type CPU module. With the expansion connectors MicroSmart. aligned correctly, press the CPU module and I/O • Failure to turn power off may cause electrical shocks or fire module together, and push in the unlatch button to hazard. Emergency stop and interlocking circuits must be configured 90.0 attach the modules together firmly. outside the MicroSmart. If such a circuit is configured inside the MicroSmart, failure of the MicroSmart may cause disorder of the control system, damage, or accidents. • This equipment is suitable for use in Class I,Division2,Groups A,B,C,D or non-hazardous locations only. •Warning - Explosion Hazard - Substitution of components may impair suitability for ClassI,Division2. FC5A-C10R2, -C16R2, and -C10R2C -C16R2C 80.0 • Warning - Explosion Hazard - Do not disconnect equipment 70.0 unless power has been switched off or the area is known to be Note: I/O modules cannot be mounted on the 10- and non-hazardous. 16-I/O type CPU modules. ●Mounting Modules 90.0 (Caution notices are used where inattention might cause [DIN Rail Mounting] personal injury or damage to equipment.) • The MicroSmart is designed for installation in equipment. Do Use a 35-mm-wide not install the MicroSmart outside equipment. Groove DIN rail and BNL6 • Install the MicroSmart in environments described in the mounting clips to 35-mm-wide DIN Rail 4.5* user's manual. If the MicroSmart is used in places where the secure the modules. MicroSmart is subjected to high-temperature, high-humidity, Dimensions in mm. Clamp [Direct Mounting] condensation, corrosive gases, excessive vibrations, and * 8.5 mm when the clamp is pulled out. malfunction will result. ●Wiring Use M4 mounting screws (6 mm or 8 mm long). External Power 90.0 83.0 Sensor Power + − + Sensor Sensor Power A 83.0 95.0 External Power − Sensor − − + + 1 2 3 4 5 degree 2.” • Prevent metal fragments and pieces of wire from dropping inside the MicroSmart housing. Ingress of such fragments and chips may cause fire hazard, damage, or malfunction. • Use wires of a proper size to meet voltage and current requirements. Tighten terminal screws to a proper tightening torque of 0.5 N-m. A +24V 0V DC IN 0 DC OUT COM FC5A-C10R2, -C16R2, and -C10R2C, -C16R2C • The environment for using the MicroSmart is “Pollution DC Sink Input Wiring DC Source Input Wiring FC5A-C24R2, -C24R2C excessive shocks, then electrical shocks, fire hazard, or +24V 0V DC IN 0 DC OUT COM 1 2 3 4 5 AC power supply type: Support of sensor power which is A-section of above figure is able to use instead of external power. DC power supply type: No support of sensor power. Therefore external power is required. • Use an IEC60127-approved fuse on the power line and output circuit to meet voltage and current requirements. (Recommended fuse: Littelfuse 5x20mm slow-blow type 218000 series/Type T) This is required when exporting equipment containing MicroSmart to Europe. • Use an EU-approved circuit breaker. This is required when 80.0 DC Power Wiring 24VDC + ¦ − ¦ AC Power Wiring Relay Output Wiring 100-240VAC L ¦ N ¦○ Ry.OUT COM0 0 1 exporting equipment containing MicroSmart to Europe. • If relays or transistors in the MicroSmart output modules Ry.OUT COM1 3 2 should fail, outputs may remain on or off. For output signals 90.0 83.0 which may cause heavy accidents, provide a monitor circuit outside of the MicroSmart. •Use the sensor power supply only for supplying power to sensors connected to the MicroSmart. + − 68.0 24 VDC • Do not disassemble, repair, or modify the MicroSmart ∼ modules. ヒューズ L ∼ N ヒューズ + − L L1 L2 L3 ∼ N + L4 − http://www.idec.com 2006.2 B-981 (0) 5 Installation in Control Panel & Mounting Direction When installing the MicroSmart in a control panel, take INSTRUCTION SHEET 9 Left side (TB1) No. Input No. Output - 1 I0 1 Q0 L 2 I1 2 Q1 L 3 I2 3 COM(-) - 4 I3 4 +V 5 I4 5 NC 6 I5 6 Q2 L 7 I6 7 Q3 L 8 I7 8 Q4 L 9 COM 9 COM1 - 10 COM 10 NC + Front Panel FC5A Series 20mm minimum 20mm minimum This sheet provides brief operating instructions of the MicroSmart programmable controller. For details, see 40mm minimum the MicroSmart User’s Manual(FC9Y-B927). 1 Type 20mm minimum FC5A-D16RK1, FC5A-D16RS1 20mm minimum FC5A-D32K3, FC5A-D32S3 2 NPN 80mm minimum 40mm minimum 24VDC + Wiring Duct Name & Function Right side (TB2) 2-wire Sensor COM 11 Q5 COM 12 Q6 L 13 COM 13 COM2 ~ 14 NC Always mount the slim type CPU modules horizontally on a vertical plane as shown above. Any other mounting Communication Connector Left side (TB1) Right side (TB2) No. Output 1 I0 1 Q0 L 2 I1 2 Q1 L 3 I2 3 COM(+) 4 I3 4 -V 5 I4 5 NC 6 I5 6 Q2 L 7 I6 7 Q3 L 8 I7 8 Q4 L 9 COM 9 COM1 10 COM 10 NC - 24VDC + - Dimensions 47.5 14.6 COM 11 Q5 COM 12 Q6 L 13 COM 13 COM2 ~ 14 NC 70.0 + - + - L 11 12 FC5A-D16RK1, FC5A-D16RS1 Cartridge Connector 1 Cartridge Connector 2 ~ + Analog Potentiometer Analog voltage Input 6 L COM3 2-wire Sensor Incorrect Mounting Direction Incorrect Mounting Direction Q7 16 Input PNP Power LED(PWR) Run LED(RUN) Error LED(ERR) Status LED(STAT) Input LED Output LED Port 1 15 No. Expansion Connector Incorrect Mounting Direction + FC5A-D16RS1 directions are not allowed. ( * Expansion connector seal ) + L 11 12 15 Q7 L 16 COM3 ~ FC5A-D32K3 Power Supply Terminals Assembling 90.0 3 Left side (CN1) I/O Connector 2-wire Sensor No. Input No. Output - 26 I0 25 Q0 L 24 I1 23 Q1 L 22 I2 21 Q2 L 20 I3 19 Q3 L 18 I4 17 Q4 L 16 I5 15 Q5 L 14 I6 13 Q6 L L + [ I/O Modules ] Remove the expansion connector seal (*) from the CPU module. With the expansion connectors aligned NPN 4.5* correctly, press the CPU module and I/O module together, and push in the unlatch button to attach the modules together firmly. 24VDC + FC5A-D32K3, FC5A-D32S3 [ Communication Modules ] 11.3 47.5 70.0 Remove the communication connector cover from the correctly, press the CPU module 2-wire Sensor and - + 90.0 communication module together, and push in the unlatch button to attach the modules together firmly. 4.5* NPN * 8.5 mm when the clamp is pulled out. Dimensions in mm. Remove the communication connector cover. 7 Applicable Ferrule Dimensions To crimp the ferrules shown below, use a special crimping tool (CRIMPFOX ZA3). 1 4 2 For 1-cable connection 3 Mounting Modules [DIN Rail Mounting] (AI-TWIN 2×0.75-8 GY) (AI 0.5-8 WH) (AI-TWIN 2×0.5-8 WH) Groove secure the modules. 35-mm-wide DIN Rail COM(-) 8 COM 7 COM(-) 6 COM 5 COM(-) 4 COM 3 +V 2 COM 1 +V - + 8 Input No. Output 26 I10 25 Q10 L 24 I11 23 Q11 L 22 I12 21 Q12 L 20 I13 19 Q13 L 18 I14 17 Q14 L 16 I15 15 Q15 L 14 I16 13 Q16 L 12 I17 11 Q17 L 10 COM 9 COM(-) 8 COM 7 COM(-) 6 COM 5 COM(-) 4 COM 3 +V 2 COM 1 +V - No. Input No. Output + 26 I0 25 Q0 L 24 I1 23 Q1 L 22 I2 21 Q2 L 20 I3 19 Q3 L 18 I4 17 Q4 L 16 I5 15 Q5 L 14 I6 13 Q6 L 12 I7 11 Q7 L 10 COM 9 COM(+) 8 COM 7 COM(+) 6 COM 5 COM(+) 4 COM 3 -V 2 COM 1 -V - PNP Recommended Screwdriver When wiring the Phoenix Contact terminal block, use the recommended screwdriver. No. + - Input No. Output 26 I10 25 Q10 L 24 I11 23 Q11 L [Direct Mounting] 22 I12 21 Q12 L 20 I13 19 Q13 L Use optional direct mounting strip FC4A-PSP1P and M4 18 I14 17 Q14 L 16 I15 15 Q15 L 14 I16 13 Q16 L 12 I17 11 Q17 L 10 COM 9 COM(+) 8 COM 7 COM(+) 6 COM 5 COM(+) 4 COM 3 -V 2 COM 1 -V mounting screws (6 mm or 8 mm long). (Phoenix Contact Type No. : SZS 0.6×3.5, SZS 0.4×2.5) 2-wire Sensor + - PNP FC5A-D16RK1, FC5A-D16RS1 FC5A-D32K3, FC5A-D32S3 4.3 2-φ 47.5 24.1 (Warning notices are used to emphasize that improper operation may cause severe personal injury or death.) • Turn off the power to the MicroSmart before starting installation, removal, wiring, maintenance, and inspection on the MicroSmart. Failure to turn power off may cause electrical shocks or fire hazard. • Emergency stop and interlocking circuits must be configured outside the MicroSmart. If such a circuit is configured inside the MicroSmart, failure of the MicroSmart may cause disorder of the control system, damage, or accidents. • This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. • Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. • Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. (Caution notices are used where inattention might cause personal injury or damage to equipment.) • The MicroSmart is designed for installation in equipment. Do not install the MicroSmart outside equipment. • Install the MicroSmart in environments described in the user's manual. If the MicroSmart is used in places where the MicroSmart is subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, and excessive shocks, then electrical shocks, fire hazard, or malfunction will result. • The environment for using the MicroSmart is “Pollution degree 2.” • Prevent metal fragments and pieces of wire from dropping inside the MicroSmart housing. Ingress of such fragments and chips may cause fire hazard, damage, or malfunction. • Use wires of a proper size to meet voltage and current requirements. Tighten terminal screws to a proper tightening torque of 0.5 N・m (power supply terminals) or 0.22 to 0.25 N・m (I/O terminals). • Use an IEC60127-approved fuse on the power line and output circuit to meet voltage and current requirements. (Recommended fuse: Littelfuse 5x20mm slow-blow type 218000 series/Type T) This is required when exporting equipment containing MicroSmart to Europe. • Use an EU-approved circuit breaker. This is required when exporting equipment containing MicroSmart to Europe. • If relays or transistors in the MicroSmart output modules should fail, outputs may remain on or off. For output signals which may cause heavy accidents, provide a monitor circuit outside of the MicroSmart. • Do not disassemble, repair, or modify the MicroSmart modules. Right side (CN2) No. Clamp + Left side (CN1) 24VDC + - to Q7 9 2-wire Sensor ) indicates the Type No. of Phoenix Contact. DIN rail and BNL6 clips 11 COM FC4A-D32S3 For 2-cable connection (AI 1-8 RD , AI 1.5-8 BK) ( 24VDC + Use a 35-mm-wide mounting I7 10 Right side (CN2) CPU module. With the communication connectors aligned 12 Safety Precautions Special expertise is required to use the MicroSmart. • Read this instruction sheet and the user's manual to make sure of correct operation before starting installation, wiring, operation, maintenance, and inspection of the MicroSmart. Keep this instruction sheet at the end user. • All MicroSmart modules are manufactured under IDEC's rigorous quality control system, but users must add a backup or failsafe provision to the control system using the MicroSmart in applications where heavy damage or personal injury may be caused in case the MicroSmart should fail. • Install the MicroSmart according to instructions described in this instruction sheet and the user's manual. Improper installation will result in falling, failure, or malfunction of the MicroSmart. • Make sure that the operating conditions are as described in the user’s manual. If you are uncertain about the specifications, contact IDEC in advance. • In this instruction sheet, safety precautions are categorized in order of importance to Warning and Caution: FC5A-D16RK1 the convenience of operation and maintenance, and resistance against environments into consideration. 10 I/O Wiring 24VDC + - + - 90.0 103.0 The following symbols represent a fuse and a load. L Fuse Load COM, COM(-), COM(+), COM1, COM2, and COM3 terminals are not interconnected. COM terminals are interconnected. 3.0 http://www.idec.com 2006.6