Download Tiger A Series T8 LED Tube Installation Guide

Transcript
Tiger A series T8 LED Tube
Installation Guide
Wiring Diagram - Traditional fluorescent tube retrofit
Wiring Diagram - Electronic ballast present
General (Lighting Fixture)
Operating Input Voltage
Power Factor
Color Temperature
Type Of LED
Operating Temperature
Storage Temperature
Operating Humidity
Cap Base
220 – 240 Vac, 50 - 60Hz
>0.9
2500K - 3500K (Warm White)
3500K - 4500K (Cool White)
6000K - 7000K (Daylight)
SSL Class Low Power 3020 LEDs
0 to 40 °C
-40 to 80 °C
>90% (RH)
G13
STARTER
STARTER
T8 FLUORESCENT TUBE
IRON CORE
BALLAST
AC
(LIVE)
AC
(NEUTRAL)
T8 FLUORESCENT TUBE
AC
(LIVE)
AC
(NEUTRAL)
ELECTRONIC BALLAST
CONVENTIONAL FLOURESCENT TUBE WIRING
AC
(LIVE)
AC
(NEUTRAL)
WHERE ELECTRONIC BALAST PRESENT,
IT SHOULD BE BYPASSED, AS SHOWN.
TRADITIONAL FLUORO INSTALLATION,
WITH STARTER AND IRON CORE BALLAST.
Tube Dimensions
A Series LED T8 Tube
(REWIRING 1)
Wiring Diagram - New Installation
C
A
Tiger A Series
FUSE (250VAC/2A)
A series LED T8 Tube
B
Tiger A series LED T8 TUBE
TUBE
Model
A0600
A1200
A1500
Tube Length
600mm - 3FT
1200mm - 4FT
1500mm - 5FT
Dim A (Max)
589mm
1199mm
1500mm
Dim B
603mm
1213mm
1514mm
Dim C
27mm
27mm
27mm
IRON CORE
BALLAST
AC
(LIVE)
AC
AC
(LIVE) (NEUTRAL)
WHERE IRON CORE BALLAST AND FUSE PRESENT:
REPLACE STARTER WITH FUSE SUPPLIED.
IRON CORE BALLAST CAN REMAIN IN CIRCUIT OR BE BYPASSED.
General notes before installation:
AC
(NEUTRAL)
LED TUBES DO NOT REQUIRE STARTER , FUSE OR
BALLAST . FIXTURE ONLY REQUIRES ACTIVE TO
ONE END AND NEUTRAL TO THE OTHER.
Wiring Diagram (Parallel)
Tiger
Installation illustrations:
1
Turn power off before installing the tube carefully according to these directions.
2
Ensure that the tube is installed securely into the fixture, in the same way
as a traditional fluorescent tube.
3
Do not install near hot or flammable objects.
4
Do not install the product on uneven or
oblique surfaces, as the tube must
not be bent.
5 The rated voltage is 220V~240V.
LED TUBE
LED TUBE
Oblique Surface
Do not use in supply voltage exceeding 240V.
6
LED TUBE
In case of operational failure, please switch off power and contact your
nearest Tigerlight dealer.
Tiger A Series T8 LED Tube
Tiger Light Pty Ltd 3/3 Vuko Place, Warriewood, NSW, Australia 2102
www.tigerlight.com.au
Tel: (02) 9913 8800
Fax: (02) 9913 8876