820900-UUM-B-0913 COOLING CONSERVATION To comfortably cool your home, your heat pump must remove both heat and humidity. Don’t turn your system off even though you will be away all day. On a hot day, your system may have to operate between 8 and 12 hours to reduce the temperature in your home to a normal comfort level. Keep windows closed after sundown. While the outdoor temperature at night may be lower than indoors, the air is generally loaded with moisture which is soaked up by furniture, carpets and fabrics. This moisture must be removed when you restart your system. The hotter the outside temperature, the greater the load on your system. Therefore do not be alarmed when your system continues to run after the sun has set on a hot day. Heat is stored in your outside walls during the day and will continue to flow into your home for several hours after sunset. Use your kitchen exhaust fan when cooking. One surface burner on “High” requires one ton of cooling. Turn on your bathroom exhaust fan while showering to remove humidity. You can also help your system in the summer by closing drapes or blinds and lowering awnings on windows that get direct sunlight. MAINTENANCE delivered by the blower, decreasing your units efficiency and increasing operating costs and wear-andtear on the unit and controls. AIR FILTERS 3 THRU 6 TON Units 3-6 Ton are shipped with 1" throwaway type air filters. The filter racks on 3-6 ton units will receive 1" or 2" filters. Filters can also be installed in the building at a suitable return air location if an economizer or outside air accessory is not used. Filters must always be used. They should be inspected once a month and thoroughly cleaned or replaced if it appears they are beginning to accumulate excessive dirt. Filter sizes and quantities are shown in the following table. THROWAWAY FILTER SIZES (Inches) QUANTITY PER UNIT (Nom, Tons) 3 - 6 TON 14 x 20 2 14 x 25 1 To install the filters, remove the filter access panel located to the left of the condensate drain connection as shown in Figure 1. NOTE: Filters must be installed with “Air Flow” arrows pointing inward -- toward the indoor coil. In the event the spacers in the filter section are removed, they must be reinstalled in their original position. Prior to any of the following maintenance procedures, shut off all power to the unit. In order to insure long and trouble free service from your system, we recommend periodic inspection, cleaning, lubrication and adjustment by your installing Dealer/Contractor. Be sure to ask about this service. Slide filters all the way into the filter racks provided. When more than one filter in a filter rack is required, they must butt each other when sliding into position. Replace the filter access panel. For those buildings with in-house maintenance, please follow the instructions listed below to care for your system. (2) 14" X 20" FILTERS LUBRICATION (1) 14" X 25" FILTERS Both the indoor blower motor and outdoor fan motor are permanently lubricated and require no maintenance. 3 - 6 TON FILTER CARE Filters must always be used and must be kept clean. When filters become dirt laden, insufficient air will be Johnson Controls Unitary Products FIGURE 1 - END VIEW LESS FILTER ACCESS PANEL 3 THRU 6 TON 3