Download ENDOAce®
Transcript
ENDOAce ® Notice instru minute Quick instructions Quick instructions Ndjg:cYdHeZX^Va^hi Ndjg:cYdHeZX^Va^hi ENDOAce ® GB Quick instructions Warnings, precautions for use, indications and contra indications. Please refer to ENDOAce® user manual. For optimal use, we highly recommend not to over flood the canal with irrigant. ! ■ Standard components mponents Control unit x2 File clip AC/DC adaptor and cable Lip hook Cable for For use in apex locator apex localisator mode (MANUAL PROG 00), connect the file clip to the Motor cable arm of the cable identified with a white collar. Motor support x2 Contra-angle Motor Spray nozzle ■ Description Escape Minus Plus OK button and OFF Battery level Selected apical distance Apical distance bar-graph Real time display Reverse mode indication if apical distance reached Apex reached indication Reverse mode indication if maximum torque reached Auto Stop Mode Supports to be stuck on the ENDOAce® control unit and/or your working area (handpiece holder for eg). ON Manual start and stop of the motor Type of programme (preset or manual) N° of selected programme Buzzer Selected torque value Selected speed value Torque bar-graph Real time Display Speed bar-graph Reverse Mode Auto Reverse Mode Stop + Reverse button Lateral apex locator cable connection ■ Electrical connection ■ First use Before first use, please respect a charging time of 14 hours. Motor cable connection 14 h 1 ■ Connection 1) 2) 3) Push the contra-angle until the black line is covered. 5) 4) 6) First connect the cable to the control unit. ■ 7) Connect the lip hook to the arm of the cable without white collar. Then place the lip hook on the patient’s lip. Programme selection (A) ENDO ENDOAce Ac Carte programmes MICR e Programmes Card O-ME Dema GADe END ntsp OFL progrand ez ARE mmele ly Mai HER lle O 642 ! fe A EN DO Ace r (PROG 01 g PROG 14) ESC q p ENT ESC ES If you want to modify them: p EN ENT S SC ESC q p ENT S SC ESC q p e per *Programme R-En s do HER O Apic al Rev o-S ! ENT ® END ENDOAce is now n ready to use. u ON: RUN/STOP button The apical distance is preset at 0.5 and the reaction mode is Auto Reverse. q Ac O Sha ATTE ATTENT NTIO ION !NWARNIN ! WAR G! NING Escape button: ESC Minus button: q Plus button: p OK button: ENT (Enter) A DO A Preset programmes HER EN Please consult the programmes card to know the programmes corresponding to your files. A B MANUAL PROG 01 1) Modify the apical distance: q p ENTT ENT for 3 sec Select your apical distance: q and/or p Select the programme corresponding to your file: q PROG 03 for example (programme 03) 2) Choose the reaction mode Auto Reverse* or Auto Stop* : q and/or p SC ESC q p NT ENT ® ENDOAce EN is now ready to use. Valid: ENT Valid: ENT * Attention: the selected reaction mode will be the same for all programmes. Auto Reverse / Auto Stop You have a choice between two reaction modes of the motor: Auto Reverse or Auto Stop. Auto Reverse: the motor stops, rotates backwards for a moment and then rotates forwards again. Apical distance or maximal preset torque reached Backward Forward Auto Stop: the motor stops, reverses for a brief moment and then stops. Apical distance or maximal preset torque reached Backwards STOP Audible (adjustable) alarm beeps when working within the vicinity of the apex. 2 ENDO ENDOAce Ac Carte programmes B Manual programmes (MANUAL PROG 01 g MANUAL PROG 09) ESC q p ENT ON: RUN/STOP button S SC ESC q p ENT MANUAL PROG 01 MICR e Programmes Card O-ME Dema GADe END ntsp OFL progrand ez ARE mmele ly Mai HER lle O 642 ! fe Programme selection (B) B Ace r EN DO ■ Please consult the programmes card to help you programme your own personal working sequences. HER O Sha per *Programme R-En s do HER O Apic al Rev o-S ATTE ATTENT NTIO ION !NWARNIN ! WAR G! NING S SC ESC q p ENT ENT for 3 sec. ESC q p A B ! ENT Set the speed: q and p Valid: ENT SC ESC q p ENT SC ESC q p ENT Set the torque: q and p Set the apical distance: q and p Valid: ENT Valid: ENT S ESC q p ENT Choose the reaction mode Auto Reverse* or Auto Stop*: q and p ENDOAce® is now ready to use. You can memorize your other programmes. Valid: ENT ■ Apex locator mode (MANUAL PROG 00) ESC q p EENT Connect the lip hook as indicated in the paragraph Connection page 2. Then connect the file clip to the arm of the cable identified with a white collar and the manual handfile to the file clip. Place the lip hook on the patient’s lip. In apex locator mode (MANUAL PROG 00), you can also run the contra-angle at the same time. Motor start has to be done manually by pressing the RUN button. ENDOAce® automatically starts at the entrance of the canal when the tip of the instrument makes contact with the dentin (except MANUAL PROG 00). For a manual start, press the RUN/STOP button. In each case, the motor stops as soon as the contact between the instrument and the canal is lost. In case a problem occurs, briefly press on the REV button (REVERSE) located under the display of the control unit or on the RUN/STOP in order to stop the motor. If the instrument is stuck, a second press on the REV button allows the motor to run in reverse. At 2 mm from the apex, ENDOAce® will start beeping in a changing rate. The nearer the file gets to the preset working length, the higher the beep rate becomes. 3 B ■ Switch off ENDOAce® will automatically shutdown after 15 minutes when not in use or by pressing the ESC button for 3 seconds. ■ Troubleshooting The contra-angle does not start: Check that the motor cable is properly and deeply connected to the control unit. Check that the lip hook is properly fitted to the patient’s lip. Check that the connection of the apex locator cable to the control unit is correct. Check that the lip hook is connected to the arm without white collar. Check that the contra-angle is correctly fixed on the motor (the black laser marking at the back of the contra-angle should disappear). Check that the file has a metallic shaft and not a plastic one. Check that the canal is properly irrigated: - If canal is too dry, irrigate it. - If canal is too flooded, dry it. Alternatively, start the motor manually by pressing the RUN button. The apical distance indicator alternately displays O.A (Over Apex) and E (Error) and the control unit beeps during 1.5 sec. The contra-angle is still rotating: The pulp chamber is flooded. Remove excess irrigant. You can continue to use ENDOAce® but in that case, the apical distance control function is deactivated. The control unit turns off during motor operation (excessive torque): Switch on the control unit again. Control the battery level indicator. If the battery is low, recharge batteries. Plug the adaptor on the main and continue your procedure. 4 www.micro-mega.com MICRO-MEGA® JC.AUGÉ ■ www.jcauge.com 10 / 10 REF. 60300622 5-12, rue du Tunnel F-25006 BESANÇON cedex FRANCE MICRO-MEGA® France Distribution Tél. : +33 (0)3 81 54 42 36 Fax : +33 (0)3 81 54 42 39 [email protected] MICRO-MEGA® International Distribution Tel.: +33 (0)3 81 54 42 34 Fax: +33 (0)3 81 54 42 39 [email protected]