Download M631 Arbitrary Waveform Generator

Transcript
M631 Arbitrary Waveform Generator
User’s Guide
This is done by clicking on the "Add to nets" button. When the
"Discard new net" button is pressed, the element is not added and you can
start adding a new element.
The elements in the "Nets" list will be displayed in the digital wave
screen in the same order, in which they appear in the list. When you select
an element from this list (by clicking on it in the list) it is possible to move this element upwards (by clicking on the "Up in list" button) or downwards (by clicking on the "Down in list" button) in the list. Click on the
"Remove from list" button to remove the element from the list.
The element configuration is confirmed by clicking on the "Ok"
button and the window is closed.
Pressing the "Cancel" button keeps the original configuration and
the window is closed.
TIP: All values attached to the element points are bound to pins, not
to the element name. Therefore it is possible to reconfigure (stagger)
one bus to two for example.
5.4.2. Addition of a macro
After adding a macro into the "Running
macros" list, a window is opened in which the
information about the use of the macro should
be specified. The name of the used macro is
displayed in the "Macro name" field. You can
set the number of macro repetitions (cycles) in
the "Count" indicator. All macro elements are
displayed in the list 1 and all elements of the
waveform in the list 2. All macro elements need to be attached to selected wave elements.
Drag an element from the list 1 onto an element
in the list 2 to attach the macro element to the
selected wave element.
1
2
WARNING: If there are three exclamation marks next to a signal in
the list 2, it means that a macro element containing more signals was
attached to this wave element. If there are three question marks next
to a signal, it means that a macro element with less signals was attached to the wave element. All remaining signals are given zero value.
Page 62