Controls and connection (COMPACT) TEMP will be on, if there is an over temperature in the unit LOAD (will only begin to be on, if there is a minimum of 50W per channel), accordant to the display in MONITOR CONSUMPTION CTR (Control) will be on, if a control signal is being received (normal operating status) L1 / L2 / L3 signals a failure of the corresponding phase Setting (only necessary for the first start-up) Addressing: Adjust the address of each Compact dimmer unit by turning the blue rotary switch. Each Compact Dimmer-unit needs a unique number - avoid same number at two or more units! For the at most 12 Compact dimmer units the numbers 1-9 and the letters A,B or C are intended. Other adjusments or double adjustment can cause malfunction of the dimmer. 8 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . www.malighting.de eMail: [email protected]