Controls and connection (COMPACT)
TEMP will be on, if there is an over temperature in the unit
LOAD (will only begin to be on, if there is a minimum of 50W per channel), accordant to the display in MONITOR
CONSUMPTION
CTR (Control) will be on, if a control signal is being received (normal operating status)
L1 / L2 / L3 signals a failure of the corresponding phase
Setting (only necessary for the first start-up)
Addressing:
Adjust the address of each Compact dimmer unit by turning the blue rotary switch. Each Compact Dimmer-unit
needs a unique number - avoid same number at two or more units!
For the at most 12 Compact dimmer units the numbers 1-9 and the letters A,B or C are intended. Other
adjusments or double adjustment can cause malfunction of the dimmer.