Download DC4812VRF Installation Guide
Transcript
INDOOR UNIT INSTALLATION 1. Pass the piping through the hole in the wall. See figure 9. 2. Hook the indoor unit onto the upper portion of installation plate (Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving it in left and right motions. 3. Piping can be made by easy by supporting the indoor unit with a cushioning material between the indoor unit and the wall. Remove it after finishing the piping. See figure 10 4. Press the lower left and right side of the unit against the installation plate until hooks engages with their slots. Figure 9 Figure 10 Copyright 2013 HotSpot Energy 9