Download NT Kiray200
Transcript
Description Modes flow chart LCD backlighted display MODE button MODE==mode bouton mode SET buttonSET SET==set bouton ENT==trigger gâchette ENT Up button MODE Down button Backlight and laser button Mode button 0.95 E MS Set Réglage emissivity de l’émissivité (EMS) with (EMS) up avecdown les touche and buttonshaut et bas. MODE Laser sighting output 35.2 MAX Display Affichage of de maximum la température maximum temperature MODE 17.3 MIN Display of de minimum Affichage la température minimum temperature MODE Infrared sensor 17.9 DIF MODE AVG MODE Trigger (ENT) Set technical unit (°C/°F) Battery compartment Set continuous measurement (On/Off) Set alarm (On/Off) 20.3 HAL Display of the difference of Affichage de la température temperature max. and différentielle between (entre MIN et MAX) min. temperatures Affichage la température Display of de average temperature moyenne calculée pendant une calculated over a measurement prise de mesure period Display and of thedealarm of Affichage et set réglage l’alarme de température high temperaturehaute 030 MODE LAL Display and of thedealarm of Affichage et set réglage l’alarme de température low temperaturebasse 015 MODE 23.5 TK Probe input Display ofde thelatemperature Affichage température given donnée par la sonde thermocouple K by the K thermocouple probe MODE LOG KIRAY 200 buttons 1 23.5 Display and recording of des Affichage et enregistrement temperaturesavec with SET buttonSET températures le bouton MODE Display 1 4 2 3 1 – Up button. It allows to increment emissivity and the thresholds of high and low alarm and to move to the next recorded value. 2 – Set button. It allows to activate or deactivate laser and backlight of the screen. It also allows to record a temperature. 3 – Mode button. It allows to navigate through the modes (emissivity, max. value, min. value, difference, average, high alarm, low alarm, TK value and recorded values). 4 – Down button. It allows to decrement emissivity and the thresholds of high and low alarm and to move to the previous recorded value. 1 - Continuous measurement indicator 2 - Unit of measurement (°C / °F) 3 - Low battery indicator 4 - Low alarm indicator 5 - Temperature value : MAX, MIN, DIF (difference between MAX and MIN values), AVG (average), HAL (high alarm), LAL (low alarm),TK (K thermocouple probe temperature) and LOG (recorded value) 6 - High alarm indicator 7 - EMS, MAX, MIN, DIF, AVG, HAL, LAL, TK and LOG indicator 8 - Temperature value 9 - Current measurement indicator 10 - HOLD indicator (fixed measurement) 11 - Emissivity value 12 - Laser in operation indicator