Modes flow chart
LCD
backlighted
display
MODE
button
MODE==mode
bouton
mode
SET
buttonSET
SET==set
bouton
ENT==trigger
gâchette
ENT
Up button
MODE
Down button
Backlight and
laser button
Mode button
0.95
E MS
Set
Réglage
emissivity
de l’émissivité
(EMS) with
(EMS)
up
avecdown
les touche
and
buttonshaut et bas.
MODE
Laser sighting output
35.2
MAX
Display
Affichage
of de
maximum
la température
maximum
temperature
MODE
17.3
MIN
Display
of de
minimum
Affichage
la température
minimum
temperature
MODE
Infrared sensor
17.9
DIF
MODE
AVG
MODE
Trigger (ENT)
Set technical unit
(°C/°F)
Battery
compartment
Set continuous
measurement (On/Off)
Set alarm (On/Off)
20.3
HAL
Display
of the difference of
Affichage de la température
temperature
max.
and
différentielle between
(entre MIN
et MAX)
min. temperatures
Affichage
la température
Display
of de
average
temperature
moyenne calculée pendant une
calculated
over
a measurement
prise de mesure
period
Display
and
of thedealarm
of
Affichage
et set
réglage
l’alarme
de température
high
temperaturehaute
030
MODE
LAL
Display
and
of thedealarm
of
Affichage
et set
réglage
l’alarme
de température
low
temperaturebasse
015
MODE
23.5
TK
Probe input
Display ofde
thelatemperature
Affichage
température given
donnée
par
la sonde
thermocouple
K
by the
K thermocouple
probe
MODE
LOG
KIRAY 200 buttons
1
23.5
Display and
recording of des
Affichage
et enregistrement
temperaturesavec
with SET
buttonSET
températures
le bouton
MODE
Display
1
4
2
3
1 – Up button. It allows to increment emissivity and the
thresholds of high and low alarm and to move to the
next recorded value.
2 – Set button. It allows to activate or deactivate laser
and backlight of the screen. It also allows to record
a temperature.
3 – Mode button. It allows to navigate through the
modes (emissivity, max. value, min. value,
difference, average, high alarm, low alarm, TK value
and recorded values).
4 – Down button. It allows to decrement emissivity and
the thresholds of high and low alarm and to move to
the previous recorded value.
1 - Continuous measurement indicator
2 - Unit of measurement (°C / °F)
3 - Low battery indicator
4 - Low alarm indicator
5 - Temperature value : MAX, MIN, DIF (difference between
MAX and MIN values), AVG (average), HAL (high alarm),
LAL (low alarm),TK (K thermocouple probe temperature)
and LOG (recorded value)
6 - High alarm indicator
7 - EMS, MAX, MIN, DIF, AVG, HAL, LAL, TK and LOG indicator
8 - Temperature value
9 - Current measurement indicator
10 - HOLD indicator (fixed measurement)
11 - Emissivity value
12 - Laser in operation indicator