Download See reports

Transcript
SHENZHEN EMTEK CO., LTD. REPORT NO.: ES111008006S
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
c) Regulating network limited output under normal
operating and single fault condition
N
d) Overcurrent protective device limited output
N
Max. output voltage (V), max. output current (A),
max. apparent power (VA)..................................... :
N
Current rating of overcurrent protective device (A)
N
2.6
Provisions for earthing and bonding
P
2.6.1
Protective earthing
Reliable connection of
relevant conductive parts to
the PE terminal by appliance
inlet.
P
2.6.2
Functional earthing
Compliance checked.
P
2.6.3
Protective earthing and protective bonding
conductors
Protective earthing and
protective bonding conductors
have sufficient currentcarrying capacity.
P
2.6.3.1
General
2.6.3.2
Size of protective earthing conductors
P
P
2
2.6.3.3
Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :
--
Size of protective bonding conductors
P
2
Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :
According to table 3B. 10AWG
minimum.
P
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ..................................... :
≤0.1Ω, see appended table
2.6.3.3
P
2.6.3.5
Colour of insulation................................................ :
Green-yellow.
P
2.6.4
Terminals
N
2.6.4.1
General
N
2.6.4.2
Protective earthing and bonding terminals
N
Rated current (A), type, nominal thread diameter
(mm)....................................................................... :
--
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N
2.6.5
Integrity of protective earthing
N
2.6.5.1
Interconnection of equipment
No interconnection of
equipment.
N
Page 13 of 58