Download POLOCOOL Models : PC58, PC53, PC44 & PC35

Transcript
In multi storey buildings, upper storey rooms are usually hotter and therefore harder to cool than
ground floor rooms.
3 SIZING GUIDE
In general the higher the cooling capacity (BTU/kW) of an air conditioner, the bigger the room it will cool.
(a) TThe
PC-53AP/C –– 20,000
19,000 BTU
BTU air
air conditioner,
conditioner, subject
subject to
to the
the variables
variables as
explained
in box
2, can
(a)
he PC-58AP/C
explained
in point
2, effectively
cooleffectively
rooms with
a floor
area
of between
18 of
and
39 square
metres.
can
cool
rooms
with
a floor area
between
20 and
42 square metres.
6.5m
7m
Example 1:
Example 1:
Uninsulated upper storey
Uninsulated upper storey
room with one West facing
room with one West facing
external wall.
external wall.
4m
4m
In this example, the air
In this example, the air
conditioner is suitable for
conditioner is suitable for
effectively cooling a room
effectively cooling a room
of up to 18 square metres.
of up to 20 square metres.
4.5m
5m
Example of maximum
Example
of minimum
room
size
room size
4m x 4.5m = 18m22
4m x 5m = 20m
Example 2:
Example 2:
Insulated ground floor
Insulated ground floor
room with external
room with external
walls facing East
walls facing East
6m
and/or South.
6m
and/or South.
In this example, the air
In this example, the air
conditioner is suitable for
conditioner is suitable for
effectively cooling a room
effectively cooling a room
of up to 39 square metres.
of up to 42 square metres.
Example of maximum
Example of maximum
room size
room size
6m x 6.5m = 39m22
6m x 7m = 42m
(b) The PC-44BP/C – 15,000 BTU air conditioner, subject to the variables explained in box 2, can effectively
cool rooms with a floor area of between 9 and 30 square metres.
6m
(b)The PC53AP/C – 19,000 BTU air conditioner, subject to the variables as explained in point 2, can
effectively cool rooms with a floor area of between 18 and 39 square metres
Example 1:
Uninsulated upper storey
room with one West facing
Example 1:
external wall.
Uninsulated upper storey 3m
In
thiswith
example,
the air
room
one West
facing
conditioner
external
wall.is suitable for
effectively cooling a room 4m
In
example,
air
of this
up to
9 squarethe
metres.
conditioner is suitable for
effectively cooling a room
of up to 18 square metres.
3m
4.5m
Example of maximum
room size
3m x 3m = 9m2
Example of minimum
room size
4.5m x 4m = 18m
2
6.5m
Example 2:
Insulated ground floor
room with external
Example
2: East
walls facing
Insulated
ground floor 5m
and/or South.
room with external
In thisfacing
example,
walls
East the air
conditioner
is
6m
and/or South. suitable for
effectively cooling a room
In
example,
themetres.
air
of this
up to
30 square
conditioner is suitable for
effectively cooling a room
of up to 39 square metres.
Example of maximum
room size
6m x 5m = 30m2
Example of maximum
room size
6.5m x 6m = 39m2
4 TIPS ON GETTING THE MOST OUT OF YOUR
POLOCOOL
PORTABLE AIR CONDITIONER
(c)The PC-44BP/C – 15,000 BTU air conditioner, subject to the variables as explained in point 2,
can effectively
cool rooms with
floordesigned
area of between
9 and
30 square
Portable
air conditioners
areanot
to cool
large
openmetres.
spaces.
To maximise the cooling effectiveness in an enclosed room:
6m
Example
2: before the room heats up. It is more
on early in
the day
• Turn the air conditioner 3m
Example 1:
Insulated ground floor
efficient
the air conditioner to maintain
the room at a comfortable temperature
Uninsulated
upperfor
storey
room with external
Example of maximum
room with
one
facing
than
itWest
is to
reduce an already hot walls
room
to East
a comfortable level.
facing
room size
5m
external wall.
Example of minimum
and/or South.
3m
• Close
windows, curtainsInand
external
blinds
In this
example,all
thedoors,
air
this example,
the air
3m x 3m = 9m2
conditioner is suitable for
conditioner is suitable for
effectively cooling a room
effectively cooling a room
• Seal or block major draughts.
of up to 9 square metres.
of up to 30 square metres.
room size
x 5m = 30m
of the6mroom
being cooled.
2
(d)The PC-35AP/C – 12,000 BTU air conditioner, subject to the variables as explained in point 2,
can effectively cool rooms with a floor area of between 6 and 20 square metres.
5m
Example 1:
Uninsulated upper storey
room with one West facing
external wall.
In this example, the air
conditioner is suitable for
effectively cooling a room
of up to 6 square metres.
3m
2m
Example of minimum
room size
3m x 2m = 6m2
Example 2:
Insulated ground floor
room with external
walls facing East
and/or South.
4m
In this example, the air
conditioner is suitable for
effectively cooling a room
of up to 20 square metres.
4
Example of maximum
room size
4m x 5m = 20m2