Download EVA2400 Series
Transcript
Load lines, twisted pair and/or shielded wire, shortest length possible. +V Power Supply +V -V + Load#1 + Load#2 - -V Distribution terminal + Load#3 - Fig. 2-7: Connecting multiple loads 2.7.10 Grounding Outputs Either the positive or negative output terminals can be grounded. To avoid noise problems caused by common-mode current flowing from the load to ground, it is recommended to ground the output terminal as close as possible to the power supply chassis ground. Always use two wires to connect the load to the power supply regardless of how the system is grounded. • • WARNING: The power supply shall not float outputs more than +/-600VDC above/below chassis ground. * If you request to use the power supply exceeded the limit described above, please contact TDK-Lambda. OUTPUT TERMINAL GROUNDING There is a potential shock hazard at the RS232/485 ports when using power supplies with rated or combined voltage greater than 400V with the Positive Output of the power supplies is grounded. Do not connect the Positive Output to ground when using the RS232/485 under the above conditions. 2.8 Sense Connector (J2) The Sense plug is connected to J2 connector. The power supply operates in local sensing. J2 connector should be correctly installed. In case of the inappropriate wiring or connecting of J2 connector, please note that the output voltage cannot be the same as the set value. In addition, EVA2400 series does not support the remote sensing function. (1) Sense plug (2) Connection with J2 connector Between J2-1and J2-2, Between J2-4 and J2-5: Short Contact Signal name Function J2-1 +S Remote(+)sense J2-2 +LS Local(+)sense J2-3 NC Not connected J2-4 -LS Local(-)sense J2-5 -S Remote(-)sense Fig. 2-8: Wiring of a Sense plug and J2 connector WARNING: Do not make contact –S to +V or +S to –V. The power supply may be damaged. 15