In both cases, an optional Start Trigger and optional Done Trigger are available. The Start Trigger will be activated just before the transfer initiates. The Done Trigger is activated after the
transfer completes. These triggers can be used as notification events within your hardware.
Element
Type
Description
position
POSITION
Position of the top left corner.
size
SIZE
Size in pixels.
label
TEXT
Label text, shown inside the button.
tooltip
TEXT
Tooltip text.
endpoint
HEX BYTE
Endpoint address for the corresponding Pipe In or Pipe
Out.
filename
TEXT
Optional filename to read or write. If not provided, the user
will be prompted.
length
NUMBER
For Pipe Out transfers, the length (in bytes) to read from
the Pipe Out and store in the file.
append
If present, an output file will be appended if it already exists.
starttrigger
XML
Describes the parameters of an optional Start Trigger (endpoint and bit).
donetrigger
XML
Describes the parameters of an optional Done Trigger (endpoint and bit).
XML Example:
<object class=”okFilePipe”>
<label>Pipe Out</label>
<position>20,53</position>
<size>60,20</size>
<endpoint>0xa0</endpoint>
<length>5000</length>
<tooltip>Read a file from Pipe 0xA0</tooltip>
<append />
<starttrigger><endpoint>0x40</endpoint><bit>0</bit></starttrigger>
<donetrigger><endpoint>0x40</endpoint><bit>1</bit></donetrigger>
</object>
okPLL22150
This component provides an XML method to program the on-board PLL. When provided with a
“label” parameter, this component becomes a pushbutton on the panel GUI. When that button
is pressed, the PLL is configured with the given parameters. This allows you to specify multiple
PLL configuration and provide multiple buttons to access them without going through the PLL
dialog. A convenient tooltip lists the VCO and output frequencies for the configuration.
When the component does not have the “label” parameter, this configuration is loaded to the PLL
when the profile is loaded. It is not stored to EEPROM and the component does not create a GUI
button. The only way to reconfigure the PLL (even after a new FPGA configuration file is loaded)
is to reload the profile.
Note that this element is ignored if the target device does not have a CY22150 PLL.