Download Opal Kelly
Transcript
FrontPanel User’s Manual In both cases, an optional Start Trigger and optional Done Trigger are available. The Start Trigger will be activated just before the transfer initiates. The Done Trigger is activated after the transfer completes. These triggers can be used as notification events within your hardware. Element Type Description position POSITION Position of the top left corner. size SIZE Size in pixels. label TEXT Label text, shown inside the button. tooltip TEXT Tooltip text. endpoint HEX BYTE Endpoint address for the corresponding Pipe In or Pipe Out. filename TEXT Optional filename to read or write. If not provided, the user will be prompted. length NUMBER For Pipe Out transfers, the length (in bytes) to read from the Pipe Out and store in the file. append If present, an output file will be appended if it already exists. starttrigger XML Describes the parameters of an optional Start Trigger (endpoint and bit). donetrigger XML Describes the parameters of an optional Done Trigger (endpoint and bit). XML Example: <object class=”okFilePipe”> <label>Pipe Out</label> <position>20,53</position> <size>60,20</size> <endpoint>0xa0</endpoint> <length>5000</length> <tooltip>Read a file from Pipe 0xA0</tooltip> <append /> <starttrigger><endpoint>0x40</endpoint><bit>0</bit></starttrigger> <donetrigger><endpoint>0x40</endpoint><bit>1</bit></donetrigger> </object> okPLL22150 This component provides an XML method to program the on-board PLL. When provided with a “label” parameter, this component becomes a pushbutton on the panel GUI. When that button is pressed, the PLL is configured with the given parameters. This allows you to specify multiple PLL configuration and provide multiple buttons to access them without going through the PLL dialog. A convenient tooltip lists the VCO and output frequencies for the configuration. When the component does not have the “label” parameter, this configuration is loaded to the PLL when the profile is loaded. It is not stored to EEPROM and the component does not create a GUI button. The only way to reconfigure the PLL (even after a new FPGA configuration file is loaded) is to reload the profile. Note that this element is ignored if the target device does not have a CY22150 PLL. www.opalkelly.com 59