Download Installation and Operation Manual
Transcript
11.0 Technical Specifications ELECTRICAL • System voltage ratings 12, 24, 48 Vdc • Current ratings — Battery Charge Control TS-45: 45 A TS-60: 60 A • Current ratings — Load Control TS-45: 45 A TS-60: 60 A • Current ratings — Diversion Charge Control TS-45: 45 A diversion load TS-60: 60 A diversion load • Accuracy 12/24V: ≤ 0.1 % ± 50 mV 48V: ≤ 0.1 % ± 100 mV • Min. voltage to operate 9V • Max. solar array Voc 125 V • Max. operating voltage 68 V • Self-consumption less than 20 mA • High temp shutdown 95ºC disconnect solar 90ºC disconnect load / diversion load 70ºC reconnect solar / load / diversion load • Solar high voltage disconnect HVD reconnect highest equalization + 0.2V 13.0V • Transient surge protection: pulse power rating response 4500 watts < 5 nanosec BATTERY CHARGING / RTS • Charge algorithm: PMW, constant voltage • Temp comp. coefficient –5mV/ºC/cell (25ºC ref) • Temp comp. range: –30ºC to +80ºC • Temp comp. setpoints PWM, float, equalize, HVD (with RTS option) BATTERY CHARGING STATUS LED’s G 13.3 to PWM G/Y 13.0 to 13.3 V Y 12.65 to 13.0 V Y/R 12.0 to 12.65 V R 0 to 12.0 V Note: Multiply x 2 for 24V systems, x 4 for 48V systems Note: The LED indications are for charging a battery. When discharging, the LED’s will typically be Y/R or R. 50 T E C H N I C A L S P E C I F I C AT I O N S