Transcript
Digi-Pas TM A Ventura Group of Companies Applications Digi-Pas TM Digital Level ON/OFF: Turn on/off device USER MANUAL LCD Digital Display DIGITAL LEVEL DWL80E (0.1° Resolution) ® Registered Design Product of Singapore CALIBRATION INSTRUCTIONS Aluminium Structure Alternate Zero Magnet MODE: Select 0.1° or % Freeze Display value & store the value in the memory ® Registered Design For first time usage, remove the plastic strip to connect the battery. CALIBRATION PICTURE STEP 1 1.(a). Push Once on the CAL button, “CAL 1” blinks. Vial CAL: Calibrate the device calibration value The Digi-Pas™ Digital level is warranted to the original purchaser to be free from defects in workmanship and material. JSB Tech will, at its option, repair or replace any detective part which may malfunction under normal and proper use within a period of 1 (one) year from the date of shipment. The foregoing warranty shall not apply to defects resulting from misuse, abuse or transfer by the Buyer, Buyer-supplied software or interfacing, unauthorized modification or operation outside of environmental specifications for the product. JSB Tech does not warrant that the operation of the instrument software, or firmware, will be uninterrupted or error free. The exclusive remedy under any and all warrants and guarantees, expressed herein, and we shall not be liable for damages from loss or delay of equipments uses, consequential, or incidental damage. No other warranty is expressed or implied. JSB Tech specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. (b). Place DWL80E on a flat & clean surface (e.g. Table) 2.(a). Press MODE, display counts down from 10,9,8.......1, “CAL 2” blinks. E.g Table Surface Push Once “ CAL” STEP 2 (b). Place DWL80E reverse horizontal (180°) Press MODE, display counts down, “CAL 3” blinks. a. CAL (c). Place DWL80E vertically (-90°). Press MODE button, display counts down, “CAL 4” blinks. (d).Place DWL80E reverse vertically (+90°). Press MODE button, display counts down. WARRANTY Press Mode button Once b. 180° CALIBRATION DONE. NOTE: Ensure DigiPas device is kept still during calibration. CAUTION c. 90° Manufactured by JSB TECH Pte Ltd 90° Press Mode button Once Press Mode button Once CAL DigiP as device is calibrated in the factory for maximun accuracy. User can re-calibrate when necessary. Remove Screw to remove battery from the compartment Tel: 65-67780640 / Fax: 65-67770460 Email: [email protected] www.digipas.com