Transcript
Digi-Pas™ A division of Group of Companies Applications for DigiPas™ Digital Level Digi-Pas™ Digital Level USER MANUAL LCD Digital display DIGITAL LEVEL Buzzer Sound DWL-200 (0.1° Resolution) Vial Magnet Aluminum Structure Turn on/off Magnet MODE SELECT 0.1°,0.5°,1.0° , % Press & Hold to freeze or store Display value ISO 14001:2000 Cet No.: TWO4/00450EM OHSAS 18001:2007 Cet No.: SG08/50066 Tested to Comply with FCC Standards Change calibration value Product of Singapore User Instructions On/Off : Press and hold to Turn off Alt Zero: Press & Hold to freeze or store Display value. Mode : Select 0.1°,0.5°,1.0°, % Press & Hold the mode button to turn Buzzer on/off. CAL Roof/drainage Leveling Alternate Zero ISO 9001:2000 Cet No.: QSP00050 : Change calibration value (Please read the instruction below) CAUTION DigiPas is calibrated in the factory for maximum accuracy. User only re-calibrate unless necessary (b). Place DWL200 reverse horizontal (180°) Press MODE, display counts down, “CAL 3” blinks. Buzzer Beeps. E.g. Table Surface Push “Cal” ONCE STEP 2a. Press Mode button ONCE 180˚ (c). Place DWL200 vertically (-90°). Press MODE button, display counts down, “CAL 4” blinks. Buzzer Beeps. The Digi-Pas™ Digital level is warranted to the original purchaser to be free from defects in workmanship and material. JSB Tech will, at its option, repair or replace any detective part which may malfunction under normal and proper use within a period of 1 (one) year from the date of shipment. The foregoing warranty shall not apply to defects resulting from misuse, abuse or transfer by the Buyer, Buyer-supplied software or interfacing, unauthorized modification or operation outside of environmental specifications for the product. JSB Tech does not warrant that the operation of the instrument software, or firmware, will be uninterrupted or error free. The exclusive remedy under any and all warrants and guarantees, expressed herein, and we shall not be liable for damages from loss or delay of equipments uses, consequential, or incidental damage. No other warranty is expressed or implied. JSB Tech specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. Press Mode button ONCE b. (d).Place DWL200 reverse vertically (+90°). Press MODE button, display counts down. CALIBRATION DONE. NOTE: Ensure DigiPas device is kept still during calibration. For first time use, Remove the plastic strip to connect the battery STEP 1 (b). Place DWL200 on a flat & clean surface (e.g. Table) 2.(a). Press MODE, display counts down from 10,9,8.......1, “CAL 2” blinks. Buzzer Beeps. WARRANTY Calibration Calibration Instructions 1.(a). Push Once on the CAL button, “CAL 1” blinks. Buzzer Beeps. d. -90˚ +90˚ Press Mode button ONCE CAUTION Press Mode button ONCE ® c. Manufactured by JSB TECH Pte Ltd Tel: 65-67780640 / Fax: 65-67770460 Email: [email protected] www.digipas.com Registered Design JIM200-004- B11