Applications for DigiPas™ Digital Level
Digi-Pas™ Digital Level
USER MANUAL
LCD Digital display
DIGITAL LEVEL
Buzzer Sound
DWL-200 (0.1° Resolution)
Vial
Magnet
Aluminum Structure
Turn on/off
Magnet
MODE SELECT 0.1°,0.5°,1.0° , %
Press & Hold to freeze or store
Display value
ISO 14001:2000
Cet No.: TWO4/00450EM
OHSAS 18001:2007
Cet No.: SG08/50066
Tested to Comply
with FCC Standards
Change calibration value
Product of Singapore
User Instructions
On/Off : Press and hold to Turn off
Alt Zero: Press & Hold to freeze or store
Display value.
Mode : Select 0.1°,0.5°,1.0°, %
Press & Hold the mode button
to turn Buzzer on/off.
CAL
Roof/drainage
Leveling
Alternate Zero
ISO 9001:2000
Cet No.: QSP00050
: Change calibration value
(Please read the instruction below)
CAUTION
DigiPas is calibrated in the factory for
maximum accuracy. User only re-calibrate
unless necessary
(b). Place DWL200 reverse horizontal (180°) Press
MODE, display counts down, “CAL 3” blinks.
Buzzer Beeps.
E.g. Table Surface
Push “Cal” ONCE
STEP 2a.
Press Mode button ONCE
180˚
(c). Place DWL200 vertically (-90°). Press MODE
button, display counts down, “CAL 4” blinks.
Buzzer Beeps.
The Digi-Pas™ Digital level is warranted to the original
purchaser to be free from defects in workmanship and material.
JSB Tech will, at its option, repair or replace any detective part
which may malfunction under normal and proper use within a
period of 1 (one) year from the date of shipment. The foregoing
warranty shall not apply to defects resulting from misuse, abuse
or transfer by the Buyer, Buyer-supplied software or interfacing,
unauthorized modification or operation outside of environmental
specifications for the product. JSB Tech does not warrant that the
operation of the instrument software, or firmware, will be
uninterrupted or error free. The exclusive remedy under any
and all warrants and guarantees, expressed herein, and we shall
not be liable for damages from loss or delay of equipments uses,
consequential, or incidental damage. No other warranty is
expressed or implied. JSB Tech specifically disclaims the
implied warranties of merchantability and fitness for a
particular purpose.
Press Mode button ONCE
b.
(d).Place DWL200 reverse vertically (+90°). Press
MODE button, display counts down.
CALIBRATION DONE.
NOTE: Ensure DigiPas device is kept still during
calibration.
For first time use,
Remove the plastic strip
to connect the battery
STEP 1
(b). Place DWL200 on a flat & clean surface
(e.g. Table)
2.(a). Press MODE, display counts down from
10,9,8.......1, “CAL 2” blinks.
Buzzer Beeps.
WARRANTY
Calibration
Calibration Instructions
1.(a). Push Once on the CAL button, “CAL 1” blinks.
Buzzer Beeps.
d.
-90˚
+90˚
Press Mode
button ONCE
CAUTION
Press Mode
button ONCE
®
c.