Download E-70N
Transcript
E-70N Used iniectiOn Needie Melting Device ◆ This manual provides instructions to ensure safe use of the syringe needle melting unit. Please read it thoroughly before operation. ◆ Please keep this manual nearthe syringe needle melting unit at a‖tirnes so thatit can be referred to whenever necessary. INttRODUCttiON Thank you for purchasing our syringe need!e melting unit.This userls manual describes how to operate it,and provides instructions which should owed be fo‖ during operation. Please keep this rnanualin a safe place,and referto it before use and whenever necessary. Maior Features □丁he unitis designed for use with various types of need!es. The unique fusing system can efficiently process 27G 1 8G‐ type of needles. □Manages 400 needles with a sing!e charge. lt can handle 400 of 23G type of need!es with on!y a single battery charge.The processing tirne per a syringe is at approximate!y2or 3 seconds.(Required 14 hours to recharge the emp‖ ed battery) □Removes unpleasant odor. The exclusive deodorant!iqu:d is attached to this device,and it removes unpleasant odor when rnelting needles with b!ood etc. □Compact designed and portable. carried and used atlocations with no access to VVith the rechargeable battery,it can bey eas‖ AC powersupply. □Secured against electromagnetic wave. The outside of frame is made of Aluminum die‐ cast so that it can prevent from a!eak of electromagnetic wave which gives a bad inf!uence to patients and other rnedica!devices. Federal CommunicaJons Commission(FCC)Declaralon of Conformky. This equipment has been tested and found to comply with the limits for a Class B d:gital device, pursuant to Part 15 of the FCC Rules.These!innits are designed to provide reasonab!e protection against harmful interference in a residentia! insta‖ ation.丁his equipment generates,uses,and can radiate radio frequency energy and,if not:nsta‖ ed and used in accordance with the instructions, may cause harmfu! :nterference to rad:o communications. However, there is no guarantee that interference w‖ l not occurin a particuiar insta‖ ation.lf this equipment does cause harmfulinterference to radio or television reception, which can be deternlined by turning the equipment off and on,the user is encouraged to try to correctthe interference by one or rnore ofthe owing fo‖ rneasures. ◆ Reorient or relocate the receiving antenna. ● lncrease the separation beh″ een the equlpment and receiver. ◆Connectthe equipmentinto an outlet on a circuit differentfrom thatto which the receiveris connected. OConsultthe dealer or service representative for he!p esOftic」apan Co.,Ltd.is not responsible for any radio or te!evision interference caused by using other than recommended cables or connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications cou!d void the user's authority to operate the equipment This device complies with Part 15 of the FCC Rules.Operalon is subieCt tO the fo!!owing two condlions:(1)thiS device may not cause harmful interference,and(2)this device must accept any interference received,inc!uding interference that may cause undesired operation Responsib!e party: Softic」 apan Co.,Ltd. 1‐ 4,Koami¨cho,Nihonbashi,chuuou¨ku,Tokyo,103‐0016,Japan 丁elephone:03¨5645‐3500 Copyright 2005 Softic」 apan co.,Ltd,A‖ rights reserved READ ALL!NSTRUCT10NS BEFORtt US:NG ttHE APPL:ANCE IMPORTANT SAFEGUARDS DANGttR‐ To reduce the nsk Of e!ectroculon: 1.Do not use wh‖ e bathing 2 Do notp!ace or store product where it can or fa‖ be pu‖ ed into a tub or sink quid. 3.Do not place in or drop into water or other‖ 4 Do not reach for a productthat has en fa‖ into water. WARNING‐ To reduce the nsk Of burns,electroculon,lre,oriniury to persons. l Close supervision is necessary when this product is used by, on, or near children orinva!ids. 2.Use this product only for lts intended use as described in th:s manua!. Do not use attachments notrecommended by the manufacturer. 3.Never operate this product if it has a damaged cord or p!ug, if it is not working properly,ifit has been dropped or damaged,or dropped into water. Return the productto a service centerfor examination and repair. 4.Never block the air openings of the product or place it on a soft surface, such as a bed or couch,where the air openlngs may be b!ocked.Keep the air opening free of!int,ha:r,and the!lke. 5.Never drop orinsert any ouectinto any opening or hose 6.Do not use outdoors or operate where aerosol(spray)prOducts are being used or where oxygen is being administered. SAVtt THES匡 :NSttRUCT!ONS ▲WARNING ▲ CAUT10N VVARNING‖ signs during operation may result in F a ‖u r e t o h e e d ‖ senOus iniury or death. 10N‖signs during operation may resultin serious Failure to heed‖ CAU¬「 in,ury. Positionlng and Power Supply ∪se the charger attached to the unit Be sure that the power supply voltage complies with Do not put the unit in an unstable place lf it the rating marked on the unit Use of a wrong should fa‖, personal iniury or damage to the power supply voltage may result in fire, unit may result. electric shock or destruction of the device. Do not connectthe power cable to an adapter Make sure that there is no dust or foreign connecting numerous cab!es, and do not matter on the unit side charge adapter rework the cable. Do not put heavy obleCtS terminal and the DC output plug on the on the power cable or heat or pu‖ it Fire or attached adapter Fu‖y insert the DC output electric shock may result plug into the unit side Loose connection may result in fire or electric shock ①乙 σ Do not put anything otherthan syringe needles Device Use into the syringe needle inlet. lf meta:s or Do not remove, disassemb!e, or recondition ‖ ammable ouects are entered,lre,damage, the cover on the unit. Fire, electric shock, personal iniury or marunc10n may result lf personaliniury or marunc10n may resun. foreign ouects are entered by mistake,turn off the power switch and stop the unit Do not put hands or foreign obieCtS into the When disposing of syringe needles, be sure unit through the dust box tray in!etlectric E二 that there is no flammable obleCt near the shock,iniury or damage to the unit may unit, and that there is no !eakage of result. combustible gas Do not use the unit in a room where combustible gas may be produced as this will resu!tin an explosion. Be sure that syringe need:es comp!y with the The unit should not be used if there is a specifications :f too long a needle for the possibillty that a syringe contains liquid which syringe needle inlet is entered, electronic can produce volatile toxic substances. devices in the vicinity may be affected by Poisoning may result spark discharge OC勁 !V Table of contents Part Names and Funclons・ ・・・・。(1) Basic Functions・ ・・・・・・・・・・・・。(2) ・… … 。(4) :nieCtiOn Needle Fusing… Before Operalon… ・… ・… ・… ・・(4) Operalon… … ・… ・… ・… 。… … (5) Battery Charging 。・・・・・・・・・・・。(7) C!eaning・・・・・・・・・・・・・・・・・・。(3) Fo‖ow the instructions below for storing the unit・・。(8) Dust Box・・・・・・・・・・・・・・・・・・・(9) Specifications ・・・・・・・・・・・・・・(10) Battery check lamps indicate remaining battery power TO carry the unit needle inlet Supports syringes Syringe needle lnlet Connects to the DC output plug ofthe charge adapter Power swlch To turn power on/off Dust box tray Tray containing dust box For rne:ted syringe needles Basic Functions Explanation of unitis basic functions Handle Hold the handle firmly when carrylng the unit When putting the unit down, take care not to cause impact. Power Swlch Forturning power on and off. ON:The battery check lamps on top ofthe unlt light to indicate that the unitis ready for use. OFF:The unit cannot be used. Power Swnch:The Automalc Off y turned The power switch may be automatica‖ off for safety. ln either of the fo‖cases, owing power will not come on or will be automa‖ cally turned off: ●Abnormality is sensed in the electric current used for operation. OThe dust box tray ls not set properly. Battery Check Lamps 丁he remaining battery power is shown by the indicator on top ofthe unit Red Green Green (1)● ● ● :Fu!ly charged (2)● ● ○ :Mening pOSSible (3)● ○ ○ :Batery charging necessary When status(3)is indiCated, stop the unit irnrnediateiy and recharge the batteries (See battery charging on page 7.) (2) Charging Adapter Terminal VVhen charging the batteryl connect the charge adapter(See battery charging on page 7.) Dust Box Tray Metallic scraps d:scarded ounng mehing are contained in a dust box which is held in the dust box tray. Oif waste:n the dust box reaches the red line, dispose the scrap only. (3) Before Operation Before use,check the fo‖ owing: 1)The dust box is properly fixed to the dust box tray 2)Check that the waste levelin the dust box is below the red line. The dust box tray is properly closed 丁he thickness,!ength and shape of syringes and syringe need:es comp!y with the specifications (See Specifications on page 1 0) ▲ WARN:NG lniec10n‖ purged from syringe (4) quid and blood must be Operation l f t h e硼雨e m お り山∝‖a m p ぃ :o"∝ 酬 山m g 酬 鴫 d"mm“ ndy ttd char" the battery.丁 o carry out rne!ting,fo‖ ow the procedure below: 1)丁urn on the powerswnch ecOnfirm thatthe battery check‖ ghts are on. 2)Ho!d the syringe fitted with a need!e vertlca‖ y above the unit,and feed itinto the in!et s!owly. 3)Ensure that the syringe blocks the syringe needle inlet hole completely (5) 4)Depress the syringe needle in!et plate s!owly, with the syringe,until lt stops. The need!e is now being melted During melting the light of electrical discharge may be visib!e through the inlet plate ▲C A U T : O N D o n o t r d e a s e t h e s y n n 9 e d u n n mening,as this may resun in burns Oriniury NOTE: Push the plate down slowly with the syringe,for about three seconds until it stops For a need!e thicker than 23G,take more tirne (fOr eXample,about five seconds)when pushing the plate down. Performing this operation in less time will not result in proper rnelting. nge 5)When mening is lnished,withdraw the sy‖ slowly. ▲C A U T : O N s y r i n g e n e e d ! e s a r e c u t a t a imeters from their root. distance of several mi‖ The roots ofthe needles will be heated to a high l result in temperature. Do not touch as this w‖ iniury or burns 6)After complelon of mening,wan thirty seconds before switching off. ▲C A U T 1 0 N D o n o t s w n c h o f f a t c o m t t e l o meltlng Gas and odors produced during meiting wi‖remain inside the unit.Their remova:requires at least thirty seconds OFF― → ON (6) lfthe middie battery check lamp 9oes out during rnelting,stop imrnediate!y and charge the battery 聞 l u r e t o t t s 酬 Ю釧 旧 n n e e d ∝ 田 ∞ 而 「叩 酬 y m e l t “0 ↑ ∝ Du‖ng charging the!eft hand red lightis lt to indicate charging in progress(●○ ○) On complelon of charging this‖ ght wil!go out(○ ○ ○). Fu‖charge tirne is approximately twelve hours Fu‖charge is recommended to have a longer battery!ife Battery Charging 丁he battery charging procedure is asows: fo‖ 1)Turn Offthe power swnch On the mening unl. OFF― → ON 2)ConneCt the DC output plug on the charge adapter to the charge adapter terminal on the unit. !nsertthe AC plug into the AC plug receptacle l light The left hand red battery check lamp w‖ d u n n g c h a r g i n g ( ●○ ○) . y charged,this iamp wi!│ VVhen the battery is fu‖ g o o u t ( ○ ○ ○) . N()TE:The operation ofthe unitis possible even ︵ 一 during charging. m剖 h8inЪ C8rgeぶ _〔 ざ 〔 〕 (7) 丁he enclosure surface, dust box tray, and other parts of this equipment wil! become dirty as this equipment is used for long. When they become dirty, clean them as shown be!ow l)丁 urn the power swnch Off Disconnect DC output plug of Charge adapter from Charge adapterterminal. 2)Wipe dirty parts:ightly with gauze or soft cloth moistened with neutral detergent diluted with water or a!cohol. 3)Moisten cioth lightly by hand lf the cloth is soaked with too much detergent or alcohol,the enclosure surface remains wet after cleaning and residual detergent or alcohol may penetrate into the product,causing damages to interna!parts. 4)After wiping,leave it until lt dries completely.Do not attempt to turn on the powerimmediately after wiping. 5)Never use thinner or organic so:vent. 1)Pu‖ Outthe dust box,then store the dust box and the unit separately. 2)Charge the battery for more than 12 hours every three months when the unl ls not used for a long tirne 3)Keep the unitin the p!ace without direct sun light. (8) Before commencing me!ting,check that the waste leve!is below the red line in the dust box lf the red line has been reached,dispose the scrap only. 1)Turn Offthe power swnch 2)Pu‖ outthe dust box tray. 3)Dispose the scrap only. ▲ WARNING After mening,waste and iniec10n liquid will be presentin the dust box Such matter is very dangerous and should not be touched by hand under any circumstances. NOTE: 匡nsure that the dust box lid is open properly. 0!f the dust box is not set proper!y,the power switch cannot be turned on. 4)匡 nsure that the dust box tray is completely pushed in(unti:it stops). N()TE:lfthe dust box tray is not set properly,the power switch cannot be turned on (9) ltems Specificat:ons ▲ lndoor use On!y. This equipment sha‖ be used indoor only. Operation tirne Approx.3 seconds(For a 23G,linch need!e) Applicable Syr:nge needles 丁hickness:16G to 30G O Standard plate:needle!ength o.5‐ 1.5 inch Syrlnge diameter O.26‐ 1.18 inch Power supply Battery(charging depends on charge adapter) !nsta‖ ation category Ⅱ Po‖ution degree 2 Anitude Up to 2000m (6560 feet) Charge Adapter AC 120V(+55%,‐ !nput 9V== Battery 淵孵‖ ::亀 γ 硝愧ξ 魂1計check 1:‖ は RIЪ 麗臨M∫ 155%)60Hz 抑0 i轍鸞濶 :聯糊ゎ Fuse (Fl)T2A/125V;(F2)丁 Dust Box Replace at about 2000 23G linch needles(conSumables) Operating environment 40℃ ★ ・Temperature:5℃ ‐ 3A/125V ser宙 Ceman replace only ★ 35℃ も a ma劇 mumbmpttuЮ du‖ ng battew chaun⊆ ・Humid“ y:20%‐ 80%RH(at 25 Lifespan 5 years or 300,000 23G linch needles,whichever rnay be earlier (eXCepting the battery) Dimenslons 7.87X7.75X6.69 inch(WxDXH) Weight Unit,5kg;charge‐ adapter,o6kg Accessorles Userls rnanual,Charge adapter,dust box Term of warranty 1(One)year After about a 1 2 hour battery recharging period,the unit can melt approx.400 of 23G linch syringe needles. The fo‖ owing types of syringe with the above applicable syringe needles can be operatedi normal syringe, and tubercu‖ n syringe. Butterfly‐ winged syringe, blood co‖ e ction syringe, denta:syringe and other special syringes are not applicable forthis unit (10)