Download Communication/CompoWay/F
Transcript
Appendix A-16 0A6C 0A7E 0A8C 0A8E 0036 003F 0046 0047 Modbus Address PID 7 proportional band ~ PID 8 proportional band ~ PID 8 automatic selection range upper limit (PV) PID 8 automatic selection range upper limit (DV) Setting data CH CH CH CH CH CH Setting (monitor) value input Analog input: -110% to 110% of scaling range However, maximum is H'FFFFB1E1 to H'0001869F (-19999 to 99999) *4 8.aut Same as display range of "Present value (PV)" *2 8.aut Temperature input: Specified range of sensor 8.p 7.p Attributes Character Character 1450.0 1650.0 Default value According to input type According to input type Decimal point position EU EU Units Set value 0B00 0B02 0B04 0B06 0B08 0B0A 0B0C 0B0E 0B20 0B46 0B48 0B6E 0000 0001 0002 0003 0004 0005 0006 0007 0010 0023 0024 0037 Modbus Address Straight-line approximation 1 input 1 Straight-line approximation 1 input 2 Straight-line approximation 1 output 1 Straight-line approximation 1 output 2 Straight-line approximation 2 input 1 Straight-line approximation 2 input 2 Straight-line approximation 2 output 1 Straight-line approximation 2 output 2 Broken-line approximation 1 input 1 ~ Broken-line approximation 1 input 20 Broken-line approximation 1 output 1 ~ Broken-line approximation 1 output 20 Setting data 0.000 0.000 0.000 -1.999 to 9.999 -1.999 to 9.999 -1.999 to 9.999 Common fo20.1 H'FFFFF831 to H'0000270F (-1.999 to 9.999) to to to to to to to to to Common fi20.1 H'FFFFF831 to H'0000270F (-1.999 to 9.999) Common fo01.1 H'FFFFF831 to H'0000270F (-1.999 to 9.999) -1.999 -1.999 -1.999 -1.999 -1.999 -1.999 -1.999 -1.999 -1.999 Default value 0.000 1.000 0.000 1.000 0.000 1.000 0.000 1.000 0.000 H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) H'FFFFF831 to H'0000270F (-1.999 to 9.999) Common si1.1 Common si2.1 Common so1.1 Common so2.1 Common si1.2 Common si2.2 Common so1.2 Common so2.2 Common fi01.1 Character 9.999 9.999 9.999 9.999 9.999 9.999 9.999 9.999 9.999 Setting (monitor) value Attributes Character 3 3 3 3 3 3 3 3 3 3 3 3 Decimal point position "H' -" indicated in set values (monitor values) are values set by communication (monitor). *1 .... These are set values for each of the operation functions. Set normalized values based on the input data for the operation function. When a straight-line approximation is included in the input stage of input type K -200.0 to 1300.0°C, -200.0 to 1300.0°C is equivalent to the normalized value 0.000 to 1.000. CB CompoWay/F Variable type Address Approximation setting level −*1 −*1 −*1 −*1 −*1 −*1 −*1 −*1 −*1 −*1 −*1 −*1 Units Set value *1 .... Not displayed in HMI. *2 .... Specified upper limit of input The maximum is -19999 to 99999. *3 .... Temperature input: Specified range width of sensor input Analog input: -110% to 110% of scaling range width The maximum is -19999 to 99999. *4 .... The upper limit of the automatic selection range of PID set No. 8 is fixed at 999.99% FS for internal data (this can be changed but it will not affect operation). *5 .... Selected PID set number. CA CompoWay/F Variable type Address Appendix