Functions (continued) Variable speed drives for asynchronous motors 563723 Altivar 31 Fault management with PowerSuite for PC # Fault management There are different modes of operation on a resettable fault: 5Freewheel stop 5The drive switches to the fallback speed 5The drive maintains the speed at which it was operating when the fault occurred until the fault disappears 5Stop on ramp 5Fast stop The detected resettable faults are as follows: 5drive overheating 5motor overheating 5CANopen bus fault 5Modbus serial link failure 5external faults 5loss of 4-20 mA signal # Fault reset Used to clear the last fault by means of a logic input. The restart conditions after a reset to zero are the same as those of a normal power-up. Resets the following faults: overvoltage, overspeed, external fault, drive overheating, motor phase loss, DC bus overvoltage, loss of 4-20 mA reference, load veering, motor overload if the thermal state is less than 100%, serial link fault. "Line supply undervoltage" and "line supply phase loss" faults are reset automatically when the line supply is restored. Function suitable for applications where the drives are difficult to access, for example on moving parts in material handling systems. # General reset (resets all faults) This function can be used to inhibit all faults, including thermal protection (forced operation) and may cause irreparable damage to the drive. Function suitable for applications where a restart can be vital (conveyor in a furnace, smoke extraction station, machine with hardening products which need to be removed). The function is enabled by a logic input. Fault monitoring is active if the logic input is at state 1. All faults are reset on a change of state of the logic input. # Controlled stop on loss of line supply Used to control motor stopping on a loss of line supply. Function suitable for material handling, machines with high inertia, continuous product processing machines. Type of stop possible: 5locking of the drive and freewheel stop 5stop which uses the mechanical inertia to maintain the drive power supply as long as possible 5stop on ramp 5fast stop (depends on the inertia and the braking ability of the drive) # Stop mode in the event of a fault The type of stop that occurs on detection of a fault can be configured as normal, freewheel or fast for the following faults: 5external fault (detection enabled by a logic input or a bit in a Modbus or CANopen control word) 5motor phase loss fault If a downstream contactor is being used between the drive and the motor, the motor phase loss fault should be inhibited. Presentation: pages 2 to 9 56 Characteristics: pages 10 to 13 References: pages 14 to 17 Dimensions: pages 30 to 35 Schemes: pages 36 to 39 0