Download mR10000 Recorder User`s Manual
Transcript
9.6 Specifying the Timer Used in Statistical Calculations (TLOG) Explanation Timer No. There are three timers. Periodic: The timer for determining the periodic printout interval. The computed result is printed every interval, and the computed TLOG value is reset. 1: The timer of timer No. 1. Specify whether the computed value is printed every interval and whether to reset the computed value. 2: The timer of timer No. 2. Specify whether the computed value is printed every interval and whether to reset the computed value. • Timer operation The table below shows how each timer operates. Timer # Item Application Target channel Periodic Periodic Measurement and computation channels Timer mode** Absolute time mode Reset computed TLOG value Yes Print when computation No stops 1 and 2* TLOG computation Computation channels Absolute or relative time mode Yes/No selectable Yes * For the timer 1 and 2 settings, see section 9.12. ** Absolute time mode: Keeps time from the reference time. Relative time mode: Starts the time in sync with the starting of the computation. SUM scale Set the sum scale when using statistical calculation (TLOG.SUM). For the definition of the term “sum scale,” see page 7-14. Off: Simply sums the computed values. /s: Sums by converting the computed values to a value over 1 second. /min: Sums by converting the computed values to a value over 1 minute. /h: Sums by converting the computed values to a value over 1 hour. /day: Sums by converting the computed values to a value over 1 day. <Related Topics> Setting the periodic printout timer: Section 7.8 Setting Timer 1 and Timer 2: Section 9.12 9-14 IM 04P01B01-01E