Download Section VIII: MEASUREMENT PROTOCOLS

Transcript
® Beginning with training plate "C" say, "JFe 're going to do this in the same way as we did
with your son/daughter. Let's try a couple of practice one's first".
. ® Point to all four pictures on training plate "C" using a circular motion with your index
finger, being careful to point to all four pictures equally. At the same time say, "There
are four pictures on this page. Each is numbered. I will say a word and then I want you
to tell me the number of or point to, the picture that best tells the meaning of the word.
Let's fry one. Which picture best describes parrot? "
- If the participant correctly points to the parrot in quadrant 2, say, great! Let's fry
another one. Which number is scissors?
- If the participant answers incorrectly, point to the correct picture and repeat the
name saying. No, actually, this is parrot. Let's fry again. What number is
parrot? Have the participant point to the correct picture on his/her own.
® In order to begin the test, the participant must answer correctly, without help, at
least 2 consecutive training words on BOTH training plate "C" and "D".
® Turn the booklet to set 13, item 145 (Note: The Research Assistant will need to flip the
booklet around completely and use the other side of the booklet pages at this point).
The test is then administered in the following manner:
® Telling the participant that you are going to begin, use a circular motion with your index
finger to point to all four pictures equally. Beginning with number 145 of set 13 on
the scoring sheet say, here are four pictures again. Which picture describes syringe? Or
which picture is syringe? Or what number is syringe?
« Record the quadrant number that the child points to in the response space on the scoring
sheet. If the response is wrong, circle "E" for error AND write the incorrect response in
the response space.
® Continue administering the test in this manner.
® If the participant makes 2 or more errors in'set 13, the Research Assistant should go
back to set 12 and continue administering the test from there. Continue backwards in
sets until the participant makes 0 or 1 error(s) within a set. Move forward to set 14 only
if the participant makes 0 or 1 error(s) in set 12. If, however, the participant makes 8
or more errors in set 13, the Research Assistant should not continue to set 14.
© Discontinue administration when the participant makes 8 or more errors in a 12-item
set. It is not necessary that these errors be sequential. Importantly, any set that has been
started should be finished. Test administration should never stop mid-set.
® When the child has reached the error threshold (8 or more incorrect responses in a 12
item set), record the number of errors for each set in the "No. of Errors" box at the end
of each set on the score sheet.
c) Scoring
After administering the PPVT, the Research Assistant is responsible for scoring the test. The
following items should be scored:
Ceiling Item: the.last item in the last completed set should be recorded in the space marked
"ceiling item."
Diet-Asthma Manual of Operations
Section VIII- Measurement Protocols
Page 37 of 38