Download Datasheet - AEMC Instruments
Transcript
EA SUR ES M ▼ ''' ''' ' D D EM AN $ AC KS E RE O EN RG ST TR Y C MO T E V1 V2 V3 N 1000V CAT III I1 I2 TO G RI N MO NI ON /OFF START/STOP Models PEL 102 & PEL 103 Visit the PEL 100 Series website for more information on software, specifications and more! Monitor your power & energy usage & costs locally or from anywhere in the world! SPECIFICATIONS I3 600V CAT IV MODEL PEL 103 POWER & ENERGY LOGGER POWER QUALITY ANALYZERS, METERS & LOGGERS Power & Energy Loggers PEL 100 Series ► Special product features MODELS PEL 102 & PEL 103 GENERAL Sampling Frequency Data Storage Rate Demand Period Storage Rate Recorded Parameters (Single- and Poly-Phase) Event Log Front Panel Indicator LEDs Storage Capacity INPUTS Voltage Current ELECTRICAL VOLTAGE MEASUREMENT Single-Phase RMS Voltages Phase-to-Phase RMS Voltages Single-Phase RMS Voltages Phase-to-Phase RMS Voltages 50/60Hz 400Hz DC PT Ratios CURRENT MEASUREMENT Current Probe: MiniFlex Sensor MA193*** ® CT Ratios POWER MEASUREMENTS Active Power (P)* Reactive Power (Q)* Apparent Power (S)* Power Factor Tangent φ (active/reactive power ratio) ENERGY MEASUREMENTS Active Energy (EP) Reactive Energy (EQ) Apparent Energy (ES) THD Individual Harmonics External Supply Back-Up Power Source/Charge Time Battery Life MECHANICAL Communication Ports Dimension/Weight Case/Index of Protection Mounting/Security DISPLAY Display Type for Model PEL 103 128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz) 1 per second User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes) V, I, W, VA, var, PF, Tan, Wh, VAh, VARh, THD (V and I), Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF Tracks and records status changes and error messages along with recorded data Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported 3 voltage input channels via 4mm safety banana jacks 3 current input channels via custom 4 pin jacks that accept AEMC probes and sensors ® RANGE 42.5 to 69Hz 10 to 1000Vrms 17 to 1700Vrms 340 to 460Hz 10 to 600Vrms 17 to 1200Vrms 100 to 1000V Programmable from 50V to 65,0000V RESOLUTION – 0.1V 0.1 to 1V – 0.1V 0.1 to 1V 0.1V 0.01V to 0.1V * ACCURACY (% of Reading) ±0.1Hz ±0.2% Rdg ± 0.2V ±0.2% Rdg ± 0.4V – ±1% Rdg ± 1V ±1% Rdg ± 1V ±1% Rdg ± 3V (typical) – 200mA to 100Arms 0.8A to 400Arms 4A to 2000Arms 20A to 10,000Arms 1 to 100mA 10 to 100mA 0.1 to 1A 0.1 to 10A Programmable from 1:1 to 25,000:1 (probe dependent) -2 to 2GW -2 to 2Gvar 0 to 2GVA -1 to +1 -3.2 to +3.2 0.001W 0.001var 0.001VA 0.001 0.001 0 to 4 x 1018 0 to 4 x 1018 0 to 4 x 1018 1Wh 1varh 1Vah ± 655% 1 to 50 displayed in percentage; 1 to 7 at 400Hz 110V/250V (10%) @ 50/60Hz; 400Hz Rechargeable 8.4V NiMH battery pack / Approximately 5 hours 30 minutes minimum, 60 minutes typical ±1.2% ± 50mA ±1.2% ± 0.2A ±1.2% ± 1A ±1.2% ±0.5% Rdg ± 0.005% Pnom ±1% Rdg ± 0.01% Qnom ±0.5% Rdg ± 0.005% Snom ± 0.05 ± 0.02 ±0.5% Rdg ±2% Rdg ±0.5% Rdg USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 ** 10.08 x 4.92 x 1.46" (256 x 125 x 37mm) / <1kg Double insulated, rubber over-molded, polycarbonate UL94 V1 rated / IP54 non operating Embedded magnets on back side, keyhole slot on back side / Kensington anti-theft system 2.63 x 2.16" (67 x 55mm), four line, monochrome, backlit LCD with adjustable brightness and contrast ENVIRONMENTAL / SAFETY Operating Temperature/Relative Humidity 50° to 122°F (10° to 50°C) / up to 85% Storage Temperature -4° to 122°F (-20° to 50°C) with batteries; -4° to 158°F (-20° to 70°C without batteries) Safety Rating/CE Rating Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III / 600V CAT IV, Pollution Degree 2 / Yes * Maximum value is current probe dependent. ** Computers with Class II Bluetooth will restrict range to 40 ft. Computers without Bluetooth will require a Class I or Class II Bluetooth radio adapter. *** Maximum current reduced by a factor of 2 for 400Hz fundamental frequency. 1 www.aemc.com Technical Assistance (800) 343-1391 Models PEL 102 & PEL 103 Large Functional Displays Information Mode TM IP 54 Rated SA RA Hook up, voltage and current ratios and aggregation period can be configured from the front panel of the PEL 103. Max Mode FET Y Measurement Mode Real-time updates are displayed for voltage, current, power, frequency, power factor and tangent. Harmonic Mode ETHERNET TIN G FEATURES •Simple to use, single-, dual (split-phase) and three-phase (Y, ∆) power & energy loggers •Designed to work in 1000V CAT III and 600V CAT IV environments and fits in many distribution panels •Power measurements: VA, W and var •Energy measurements: VAh, Wh (source, load) and VARh (4 quadrants) •DataView software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates •Ethernet compatible •Minimal programming required •Displays stored measurements display or via Bluetooth (Class 1 - communicates up to 300 ft) to a PC or the Android™ based mobile application •Satisfies the requirements of NEC Code 220.87 •Measures AC/DC (current probe dependent) Max values for voltage, current (including neutral current), power and harmonics. Total Harmonic Distortion (THD) can be displayed by phase or phase to phase. Neutral current THD can also be displayed. Android™ App Available! ® PRODUCT INCLUDES PEL 102 & PEL 103 Kit Small classic tool bag, three MiniFlex MA193-10BK sensors, 5 ft USB cable, four black test leads and alligator clips, power cord, 12 color-coded ID markers, Multifix mounting system, safety card, sensor compliance sheet, 2GB SD-Card with USB-SD-Card reader, quick start user guide, and USB stick supplied with DataView software and user manual. ® ●Configure Measurements and Recordings ●Display Data in Real-Time ●For Use on any Device with an Android Platform CATALOG NO. DESCRIPTION 2137.51 Power & Energy Logger Model PEL 102 (no LCD w/3 MA193-10-BK Sensors) 2137.52 Power & Energy Logger Model PEL 103 (with LCD w/3 MA193-10-BK Sensors) 2137.61 Power & Energy Logger Model PEL 102 (no LCD or Sensors) 2137.62 Power & Energy Logger Model PEL 103 (with LCD, no Sensors) Technical Assistance (800) 343-1391 ® www.aemc.com 2 POWER QUALITY ANALYZERS, METERS & LOGGERS Optional Accessories SENSOR TYPE CURRENT RANGE ACCURACY (TYPICAL) TYPICAL ERROR ON Φ AT 50/60HZ MAX CONDUCTOR SIZE USED WITH MODEL LIMITED RANGE IF USED WITH MODEL 100mA to 3000Aac ±1% 0° 2.75" (70mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 1 to 1000Aac 1 to 1300Adc ±2.5% -0.80° 1.6" (41mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 1 to 1200Aac ±0.3% +0.2° 2.05" (52mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 PEL 102 PEL 103 8333 8336 8220 8230 8435 MiniFlex® MA193 * MR193 Battery operated SR193 AmpFlex® 193 * 100mA to 12,000Aac ±1% 0° 7.64" (190mm) or 11.46" (290mm) 0.5 to 240Aac ±1% +0.8° 0.78" (20mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 ±1% +0.75° 0.78" (20mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 24" or 36" sensor MN93 MN193 100A 5A 3 www.aemc.com 200mA to 120Aac 5mA to 6Aac ±1% +1.7° Technical Assistance (800) 343-1391 POWER QUALITY ANALYZERS, METERS & LOGGERS Optional Accessories SENSOR TYPE CURRENT RANGE ACCURACY (TYPICAL) TYPICAL ERROR ON Φ AT 50/60HZ ±4% ±0.5° MAX CONDUCTOR SIZE USED WITH MODEL LIMITED RANGE IF USED WITH MODEL 0.46" (11.8mm) PEL 102 PEL 103 8333 8336 8220 8230 8435 PEL 102 PEL 103 8333 8336 8435 N/A SL261 ** 100A 10A 5 to 100Aac/dc 50mA to 10Aac/dc ±3% ±1° Battery operated J93 50 to 3500Aac 50 to 5000Adc Battery operated 2.83" (72mm) ±1% ±1° Busbar: 5 x 1.69" (127 x 43mm) * Maximum current reduced by a factor of 2 for 400Hz fundamental frequency. Note: Refer to the power meter’s product user manual for complete specifications. CATALOG NO. DESCRIPTION 1201.51 AC/DC Current Probe Model SL261 (BNC) 2140.28 AC Current Probe Model MR193-BK 2140.32 AC Current Probe Model MN93-BK 2140.33 AC Current Probe Model SR193-BK 2140.34 AmpFlex Sensor 24" Model 193-24-BK 2140.35 AmpFlex Sensor 36" Model 193-36-BK 2140.36 AC Current Probe Model MN193-BK 2140.48 MiniFlex Sensor 10” Model MA193-10-BK 2140.49 AC/DC Current Probe Model J93-BK ** AC/DC Current Probe BNC Adapter for Model SL261 only Catalog #2140.40 ® ® ® Technical Assistance (800) 343-1391 www.aemc.com 4 DATAVIEW Control Panel ® Data Analysis and Reporting Software for the PEL 100 Series 5 Basic information regarding Auto Power Off, instrument name and location, display brightness and contrast (Model PEL 103), setting of the real-time clock and SD-card formatting is easily accomplished from the General tab. The Communication tab provides information about the various communication mediums supported by the instrument with clear and easy setup of all functions from one dialog box. The Measurement tab specifies the electrical distribution system, voltage ratios, nominal frequency and current probe options and ratios. In the Recording tab, configure the instrument to measure (and record) over a user selectable recording period from a few hours to a month or longer. Select demand intervals from one to sixty minutes and view available memory for data storage. www.aemc.com Technical Assistance (800) 343-1391 DATAVIEW Graphical Display & Report Generation DataView® software provides a convenient way to configure and control power and energy tests from a computer. Through the use of clear and easy-to-use tabbed dialog boxes, all PEL 100 series functions can be configured and tests can be initiated. Configure all functions of the PEL • Display and analyze real-time data on your PC •Configure functions and parameters from your PC •Customize views, templates and reports to your exact needs •Create and store a complete library of configurations that can be uploaded as needed •Zoom in and out and pan through sections of the graph to analyze the data •Download, display and analyze recorded data •Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms •Print reports using standard or custom templates you design • Free updates are available on our website www.aemc.com Reports can be displayed on a PC and printed. Each report includes all test results in a tabular and graphic format, as well as operator and test site information. Comments typed by the operator will also be included. Typical DataView Functional, Digital & Graphical Displays ® Control Panel Trend View Title Bar Tools Menu Bar Parameter Selection Buttons Tabular Listing of Data at Cursor Position Movable Cursor Data Plot/Listing Area Logger Navigation Tree In the PEL Control Panel you will find all the necessary tools and selection buttons to review recorded data as trend plots or tabular lists. Also logger selection, when multiple loggers are detected, is accomplished in the Control Panel. Technical Assistance (800) 343-1391 www.aemc.com 6