Download Datasheet - AEMC Instruments

Transcript
EA
SUR
ES
M
▼
'''
'''
'
D
D
EM
AN
$
AC KS
E
RE
O
EN
RG
ST
TR
Y C
MO T E
V1
V2
V3
N
1000V CAT III
I1
I2
TO
G
RI
N
MO
NI
ON /OFF
START/STOP
Models PEL 102 & PEL 103
Visit the PEL 100 Series
website for more
information on
software,
specifications
and more!
Monitor your power & energy
usage & costs locally or from
anywhere in the world!
SPECIFICATIONS
I3
600V CAT IV
MODEL PEL 103
POWER & ENERGY LOGGER
POWER QUALITY ANALYZERS, METERS & LOGGERS
Power & Energy Loggers PEL 100 Series
►
Special
product
features
MODELS
PEL 102 & PEL 103
GENERAL
Sampling Frequency
Data Storage Rate
Demand Period Storage Rate
Recorded Parameters
(Single- and Poly-Phase)
Event Log
Front Panel Indicator LEDs
Storage Capacity
INPUTS
Voltage
Current
ELECTRICAL
VOLTAGE MEASUREMENT
Single-Phase RMS Voltages
Phase-to-Phase RMS Voltages
Single-Phase RMS Voltages
Phase-to-Phase RMS Voltages
50/60Hz
400Hz
DC
PT Ratios
CURRENT MEASUREMENT
Current Probe: MiniFlex Sensor MA193***
®
CT Ratios
POWER MEASUREMENTS
Active Power (P)*
Reactive Power (Q)*
Apparent Power (S)*
Power Factor
Tangent φ (active/reactive power ratio)
ENERGY MEASUREMENTS
Active Energy (EP)
Reactive Energy (EQ)
Apparent Energy (ES)
THD
Individual Harmonics
External Supply
Back-Up Power Source/Charge Time
Battery Life
MECHANICAL
Communication Ports
Dimension/Weight
Case/Index of Protection
Mounting/Security
DISPLAY
Display Type for Model PEL 103
128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz)
1 per second
User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes)
V, I, W, VA, var, PF, Tan, Wh, VAh, VARh, THD (V and I),
Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF
Tracks and records status changes and error messages along with recorded data
Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status
2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB)
formatted FAT32 are supported
3 voltage input channels via 4mm safety banana jacks
3 current input channels via custom 4 pin jacks that accept AEMC probes and sensors
®
RANGE
42.5 to 69Hz
10 to 1000Vrms
17 to 1700Vrms
340 to 460Hz
10 to 600Vrms
17 to 1200Vrms
100 to 1000V
Programmable from 50V to 65,0000V
RESOLUTION
–
0.1V
0.1 to 1V
–
0.1V
0.1 to 1V
0.1V
0.01V to 0.1V
* ACCURACY (% of Reading)
±0.1Hz
±0.2% Rdg ± 0.2V
±0.2% Rdg ± 0.4V
–
±1% Rdg ± 1V
±1% Rdg ± 1V
±1% Rdg ± 3V (typical)
–
200mA to 100Arms
0.8A to 400Arms
4A to 2000Arms
20A to 10,000Arms
1 to 100mA
10 to 100mA
0.1 to 1A
0.1 to 10A
Programmable from 1:1 to 25,000:1 (probe dependent)
-2 to 2GW
-2 to 2Gvar
0 to 2GVA
-1 to +1
-3.2 to +3.2
0.001W
0.001var
0.001VA
0.001
0.001
0 to 4 x 1018
0 to 4 x 1018
0 to 4 x 1018
1Wh
1varh
1Vah
± 655%
1 to 50 displayed in percentage; 1 to 7 at 400Hz
110V/250V (10%) @ 50/60Hz; 400Hz
Rechargeable 8.4V NiMH battery pack / Approximately 5 hours
30 minutes minimum, 60 minutes typical
±1.2% ± 50mA
±1.2% ± 0.2A
±1.2% ± 1A
±1.2%
±0.5% Rdg ± 0.005% Pnom
±1% Rdg ± 0.01% Qnom
±0.5% Rdg ± 0.005% Snom
± 0.05
± 0.02
±0.5% Rdg
±2% Rdg
±0.5% Rdg
USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 **
10.08 x 4.92 x 1.46" (256 x 125 x 37mm) / <1kg
Double insulated, rubber over-molded, polycarbonate UL94 V1 rated / IP54 non operating
Embedded magnets on back side, keyhole slot on back side / Kensington anti-theft system
2.63 x 2.16" (67 x 55mm), four line, monochrome, backlit LCD with
adjustable brightness and contrast
ENVIRONMENTAL / SAFETY
Operating Temperature/Relative Humidity
50° to 122°F (10° to 50°C) / up to 85%
Storage Temperature
-4° to 122°F (-20° to 50°C) with batteries; -4° to 158°F (-20° to 70°C without batteries)
Safety Rating/CE Rating
Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III / 600V CAT IV, Pollution Degree 2 / Yes
* Maximum value is current probe dependent.
** Computers with Class II Bluetooth will restrict range to 40 ft. Computers without Bluetooth will require a Class I or Class II Bluetooth radio adapter.
*** Maximum current reduced by a factor of 2 for 400Hz fundamental frequency.
1
www.aemc.com
Technical Assistance (800) 343-1391
Models PEL 102 & PEL 103
Large Functional Displays
Information Mode
TM
IP
54
Rated
SA
RA
Hook up, voltage and current ratios and
aggregation period can be configured from
the front panel of the PEL 103.
Max Mode
FET Y
Measurement Mode
Real-time updates are displayed for voltage,
current, power, frequency, power factor and
tangent.
Harmonic Mode
ETHERNET
TIN G
FEATURES
•Simple to use, single-, dual (split-phase)
and three-phase (Y, ∆) power & energy
loggers
•Designed to work in 1000V CAT III and
600V CAT IV environments and fits in
many distribution panels
•Power measurements: VA, W and var
•Energy measurements: VAh, Wh
(source, load) and VARh (4 quadrants)
•DataView software for configuring
real-time communication with a PC and
report generation with pre-defined or
user defined templates
•Ethernet compatible
•Minimal programming required
•Displays stored measurements display or via
Bluetooth (Class 1 - communicates up to
300 ft) to a PC or the Android™ based
mobile application
•Satisfies the requirements of
NEC Code 220.87
•Measures AC/DC
(current probe dependent)
Max values for voltage, current (including
neutral current), power and harmonics.
Total Harmonic Distortion (THD) can be
displayed by phase or phase to phase.
Neutral current THD can also be displayed.
Android™ App Available!
®
PRODUCT INCLUDES
PEL 102 & PEL 103 Kit
Small classic tool bag, three MiniFlex MA193-10BK sensors, 5 ft USB cable, four black test leads
and alligator clips, power cord, 12 color-coded ID
markers, Multifix mounting system,
safety card, sensor
compliance sheet,
2GB SD-Card with
USB-SD-Card
reader, quick start
user guide, and USB
stick supplied with
DataView software
and user manual.
®
●Configure Measurements
and Recordings
●Display Data in Real-Time
●For Use on any Device with an
Android Platform
CATALOG NO.
DESCRIPTION
2137.51
Power & Energy Logger Model PEL 102 (no LCD w/3 MA193-10-BK Sensors)
2137.52
Power & Energy Logger Model PEL 103 (with LCD w/3 MA193-10-BK Sensors)
2137.61
Power & Energy Logger Model PEL 102 (no LCD or Sensors)
2137.62
Power & Energy Logger Model PEL 103 (with LCD, no Sensors)
Technical Assistance (800) 343-1391
®
www.aemc.com
2
POWER QUALITY ANALYZERS, METERS & LOGGERS
Optional Accessories
SENSOR TYPE
CURRENT RANGE
ACCURACY
(TYPICAL)
TYPICAL
ERROR
ON Φ AT
50/60HZ
MAX
CONDUCTOR
SIZE
USED WITH
MODEL
LIMITED
RANGE IF
USED WITH
MODEL
100mA to 3000Aac
±1%
0°
2.75"
(70mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
1 to 1000Aac
1 to 1300Adc
±2.5%
-0.80°
1.6"
(41mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
1 to 1200Aac
±0.3%
+0.2°
2.05"
(52mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
PEL 102
PEL 103
8333
8336
8220
8230
8435
MiniFlex® MA193 *
MR193
Battery operated
SR193
AmpFlex® 193 *
100mA to 12,000Aac
±1%
0°
7.64"
(190mm)
or
11.46"
(290mm)
0.5 to 240Aac
±1%
+0.8°
0.78"
(20mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
±1%
+0.75°
0.78"
(20mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
24" or 36" sensor
MN93
MN193
100A
5A
3
www.aemc.com
200mA to 120Aac
5mA to 6Aac
±1%
+1.7°
Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS
Optional Accessories
SENSOR TYPE
CURRENT RANGE
ACCURACY
(TYPICAL)
TYPICAL
ERROR
ON Φ AT
50/60HZ
±4%
±0.5°
MAX
CONDUCTOR
SIZE
USED WITH
MODEL
LIMITED
RANGE IF
USED WITH
MODEL
0.46"
(11.8mm)
PEL 102
PEL 103
8333
8336
8220
8230
8435
PEL 102
PEL 103
8333
8336
8435
N/A
SL261 **
100A
10A
5 to 100Aac/dc
50mA to 10Aac/dc
±3%
±1°
Battery operated
J93
50 to 3500Aac
50 to 5000Adc
Battery operated
2.83"
(72mm)
±1%
±1°
Busbar:
5 x 1.69"
(127 x 43mm)
* Maximum current reduced by a factor of 2 for 400Hz fundamental frequency.
Note: Refer to the power meter’s product user manual for complete specifications.
CATALOG NO.
DESCRIPTION
1201.51
AC/DC Current Probe Model SL261 (BNC)
2140.28
AC Current Probe Model MR193-BK
2140.32
AC Current Probe Model MN93-BK
2140.33
AC Current Probe Model SR193-BK
2140.34
AmpFlex Sensor 24" Model 193-24-BK
2140.35
AmpFlex Sensor 36" Model 193-36-BK
2140.36
AC Current Probe Model MN193-BK
2140.48
MiniFlex Sensor 10” Model MA193-10-BK
2140.49
AC/DC Current Probe Model J93-BK
** AC/DC Current Probe BNC Adapter
for Model SL261 only
Catalog #2140.40
®
®
®
Technical Assistance (800) 343-1391
www.aemc.com
4
DATAVIEW
Control Panel
®
Data Analysis and Reporting Software for the PEL 100 Series
5
Basic information regarding Auto Power Off, instrument name
and location, display brightness and contrast (Model PEL 103),
setting of the real-time clock and SD-card formatting is easily
accomplished from the General tab.
The Communication tab provides information about the various
communication mediums supported by the instrument with clear
and easy setup of all functions from one dialog box.
The Measurement tab specifies the electrical distribution system,
voltage ratios, nominal frequency and current probe options and
ratios.
In the Recording tab, configure the instrument to measure (and
record) over a user selectable recording period from a few hours
to a month or longer. Select demand intervals from one to sixty
minutes and view available memory for data storage.
www.aemc.com
Technical Assistance (800) 343-1391
DATAVIEW
Graphical Display & Report Generation
DataView® software provides a convenient way to configure
and control power and energy tests from a computer. Through
the use of clear and easy-to-use tabbed dialog boxes, all
PEL 100 series functions can be configured and tests can be
initiated.
Configure all functions of the PEL
• Display and analyze real-time data on your PC
•Configure functions and ­parameters from your PC
•Customize views, templates and reports to your exact needs
•Create and store a complete library of configurations that
can be uploaded as needed
•Zoom in and out and pan through sections of the graph to
­analyze the data
•Download, display and analyze recorded data
•Display waveforms, trend graphs, harmonic spectrums,
text summaries, transients, event logs and stored alarms
•Print reports using standard or custom ­templates you design
• Free updates are available on our website www.aemc.com
Reports can be displayed on a PC and printed. Each report includes all
test results in a tabular and graphic format, as well as operator and test
site information. Comments typed by the operator will also be included.
Typical DataView Functional, Digital & Graphical Displays
®
Control Panel Trend View
Title Bar
Tools Menu Bar
Parameter
Selection Buttons
Tabular Listing of Data
at Cursor Position
Movable Cursor
Data Plot/Listing Area
Logger Navigation Tree
In the PEL Control Panel you will find all the necessary tools and selection buttons to review
recorded data as trend plots or tabular lists. Also logger selection, when multiple loggers are
detected, is accomplished in the Control Panel.
Technical Assistance (800) 343-1391
www.aemc.com
6