Download X - Duevi

Transcript
Learning
*0
Radio Zone 02 P
X
Learning
*_
Radio Code 02 P
Learning
*X
Radio Code 02 P
7.3.
#
21
In the selected memory location you could find the following symbols:
after “Learning”:
“X” = already a memorized sensor in this location.
“0” = free memory location.
after “Radio Zone…”
“P” = perimeter type sensor.
“T” = volumetric type sensor (PIR).
Once positioned in the desired zone:
Press “X” key quickly > You will see “_”: the control panel is now ready for
another sensor code to be programmed.
Hold down “X” key > Delete the current sensor.
Provoke an alarm signal ONLY from the sensor to be memorized, so that
it transmits its code to the control panel.
If the control panel receives a signal from the sensor correctly, it will
confirm its memorization with an “X” in the place of “_”.
If the memory is not possible the control panel will emit three “beeps”.
Learning siren tamper (only for SIRR-A/B v2)
Chose an empty sensor memory location.
Push the “#” key for at least 3 seconds and no more than 6 seconds: the control panel will send
to siren a request to transmit its own tamper code; the siren will send its code that will then be
learned.