Download PRO1D V11.122 series MID User manual
Transcript
PRO1D V11.122 series MID DIN rail single phase two wire energy meter 1.1 Safety instructions 1.2 Foreword 1.3 MID certificates 1.4 Type number table 1.5 Performance criteria 1.6 Specifications 1.7 Basic errors 1.8 Description 1.9 Dimensions 1.10 Installation 1.11 Operation 1.12 Troubleshooting 1.13 Technical support User manual Version 1.0 ® 2011 -1- User manual 0014 1.1 Safety instructions Information for Your Own Safety This manual does not contain all of the safety measures for operation of this equipment (module, device) because special operating conditions, local code requirements or local regulations may necessitate further measures. However, it does contain information which must be adhered to for your own personal safety and to avoid damage to the equipment. This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the severity of the warning. Warning Means that failure to observe the instruction can result in death, serious injury or considerable material damage. Caution Means hazard of electric shock and failure to take the necessary safety precautions will result in death, serious injury or considerable material damage. Qualified personnel Installation and operation of this equipment described in this manual may only be performed by qualified personnel. Only people that have proper knowledge about the local standards regarding electrical installations and are allowed to work on these installations according to the local regulations are considered qualified personnel in this manual. Use for the intended purpose The equipment (device, module) may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by Inepro Metering B.V. Proper handling The prerequisites for perfect, reliable operation of the product are proper transport, storage, installation and connection, as well as proper operation and maintenance. When operating electrical equipment, certain parts of this equipment carry dangerous voltages. Improper handling can therefore result in serious injury or material damage. ® 2011 Only use isolated tools suitable for the voltages the meter is used for. Do not connect while the circuit is energized (current is running). Do not connect the meter to a 3 phase - 400VAC – network. Place the meter only in dry surroundings. Do not mount the meter in an explosive area or exposed to dust, mildew and/or insects. Make sure the used wires are suitable for the maximum current of this meter. Make sure the AC wires are connected correctly before activating the current/voltage to the meter. Do not touch the meter’s connection clamps directly with your bare hands, with metal, blank wire or other conducting material as that will cause an electric shock and possibly cause injury. Make sure the protection cover is placed after installation. Installation, maintenance and repair should only be done by qualified personnel. -2- User manual 0014 Never break the seals to open the front cover as this might influence the functionality or accuracy of the meter, and will void all warranty. Do not drop, or allow physical impact to the meter as there are high precision components inside that may break and render the meter measurement inaccurate. Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions in the information given. The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions. If you have any suggestions, please let us know. Subject to technical modifications without notice. Copyright Copyright Inepro Metering March 2011 All rights Reserved. It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All rights reserved, particularly for pending or approved patents award or registered trademarks. Registered trademarks DMMetering® is a registered trademark of Inepro Metering – member of the Inepro Group. Other names appearing in this manual may be trademarks of third parties and are property of their respectful owners. 1.2 Foreword Thank you for purchasing the DMMetering PRO1 series DIN rail single phase two wire energy meter. The DMMetering PRO1 series energy meter is the most advanced type electronic kWh meter available at the market. With the DMMetering product range we have introduced a large scale of energy meters on the market suitable for 110V AC to 400V AC (50 or 60Hz). Besides the normal energy meters we also developed our own pre-paid energy and water meters with chip card or infrared card and a complete PC management control system. For more information on other products please contact our sales department at [email protected] or [email protected]. Although we produce the DMMetering PRO1 series meter according to the requirements of IEC 62053-3 and our quality inspection is very accurate there might always be a possibility that your product shows a defect or failure for which we do apologize. Under normal conditions your product should give you years of trouble free operation. In case there is a problem with the energy meter you should contact your dealer immediately. All energy meters are sealed with a special seal. Once this seal is broken there is no possibility to claim any warranty. Therefore NEVER open an energy meter or break the seal of the energy meter. The warranty period is 3 years after production, and only valid for construction faults. ® 2011 -3- User manual 0014 1.3 MID certificates ® 2011 -4- User manual 0014 ® 2011 -5- User manual 0014 1.4 Type number table: The PRO1 series is labeled as follows: PRO1D/TE V 11 . x x x 1.5 Pulse led and pulse output: 1 = 1000 impulses / kWh 2 = 2000 impulses / kWh Reverse counting: 1 = Does not count when energy is reversed 2 = Counts up regardless of energy direction Type of display: 1 = LCD without backlight PRO1D 2 = LCD with backlight PRO1D 3 = Mechanical register PRO1TE Performance criteria: Operating humidity Storage humidity Operating temperature Storage temperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter protective class 1.6 ≤ 75% ≤ 95% -10°C - +50°C -30°C - +70°C EN 50470-3 1 IP51 II Specifications: Meter type Nominal voltage (Un) Operational voltage Insulation capabilities: - AC voltage withstand - Impulse voltage withstand Basic current (Ib) Maximum rated current (Imax) Max. current for direct wire connection Max. current for busbar connection Operational current range Peak current withstand Operational frequency range Internal power consumption Test output flash rate (RED LED) Pulse output rate (pins 20 & 21) Consumption indicator (RED LED) ® 2011 PRO1 series 230V AC 161 - 300V AC 2KV for 1 minute 6KV – 1.2µS waveform 5A 45A 32A 45A 0.4% Ib- Imax 30Imax for 0.01s 50Hz ±10% ≤2W / 10VA 1000 or 2000 imp/kWh, see section 1.3 1000 or 2000 imp/kWh, see section 1.3 Flashing at load running -6- User manual 0014 1.7 Basic errors: 0.05Ib 0.1Ib 0.1Ib - Imax 0.2Ib - Imax 1.8 Cosφ Cosφ Cosφ Cosφ Cosφ Cosφ = = = = = = 1 0.5L 0.8C 1 0.5L 0.8C ±1.5% ±1.5% ±1.5% ±1.0% ±1.0% ±1.0% Description A B C D E Register Terminal block Case Protection cover Security wire slot Material Register Case Terminal block Protection cover PC inflammable plastic ABS inflammable plastic ABS inflammable plastic ABS inflammable plastic C B A D 1.9 E Dimensions Height Width Depth Weight ® 2011 117.5 mm 18 mm 58.5 mm 0.12 Kg (net) -7- User manual 0014 1.10 Installation CAUTION Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before working on it. Always use a properly rated voltage sensing device to confirm that power is off. WARNING - - - - ® 2011 Installation should be performed by qualified personnel familiar with applicable codes and regulations. Use isolated tools to install the meter. Fuse or thermal cut-off or single-pole circuit breaker should be fitted on the supply line and not the neutral line. The meter’s casing is sealed, if not properly looked after, this seal could be broken, voiding the warranty and damaging the meter. We recommend that the connecting wire which is used to connect meter to the outside circuit should be sized according to local codes and regulations for the maximum amount of current of the circuit breaker or other overcurrent protection device used in the circuit. An external switch or a circuit-breaker should be installed on the supply wires, which will be used to disconnect the meter. It is recommended that this switch or circuit-breaker is placed near the meter because that is more convenient for the operator. The switch or circuit-breaker should comply with the specifications of the building’s electrical design and all local regulations. An external fuse or thermal cut-off which will be used as an overcurrent protection device for the meter must be installed on the supply side wire, and it is recommended that this protection device is near the meter since that is convenient for the operator. The overcurrent protection device should comply with the specifications of the building’s electrical design and all local regulations. This meter can be installed indoor, or outdoor enclosed in a meter box which is sufficiently protected, subject to local codes and regulations. To prevent tampering, an enclosure with a lock or a similar device can be used. The meter has to be installed against a fire resistant wall. The meter has to be installed in a well ventilated and dry place. The meter has to be installed in a protective box if the meter is exposed to dust or other contaminants. The meter can be installed and used after being tested and can be sealed afterwards. The meter can be installed on a 35mm DIN rail. The meter should be installed on a location where the meter can be read easily. When the meter is installed in an area with frequent surges for example due to thunderstorms, welding machines, inverters etc, the meter should be protected with a Surge Protection Device. After finishing installation, the meter can be sealed to prevent tampering. Connection of the wires should be done in accordance with the following connection diagram. -8- User manual 0014 1 3 4 6 20 and 21 phase line in phase line out neutral line in neutral line out Pulse output contact 1.11 Operation Consumption indication There is a two color LED on the front panel of the meter. When the meter is powered on and no load is connected to it, the LED lights up green. When power is consumed, the LED will flash red. The faster the LED flashes, the more power is consumed. For this meter, the LED will flash 1000 or 2000 times per kWh depending on the version of the meter, see section 1.3 for details. Please note: There are two versions of this meter with a difference in how reverse current is handled. One version counts up in both directions and one only counts up in one direction and doesn’t count in the other direction. This has an effect if the meter is connected in reverse (terminal 3 Load in and terminal 1 load out) or used with any sort of energy production system (solar panels, wind generators, etc). See section 1.3 for details. Reading the meter The PRO1 series meter can be delivered with either a digital or mechanical register. See the version numbering in section 1.3. Digital register The PRO1D series energy meter is equipped with a 5+2 digit LCD which is used to record consumption and can’t be reset to zero. The display has 5 digits before and 2 decimals after the dot on the display. The reading accuracy is 1/100 kWh. Mechanical register The PRO1TE series energy meter is equipped with a mechanical 5+1 register which is used to record consumption and can’t be reset to zero. Five decimals are marked with black color and one decimal is marked with red. The reading accuracy is 1/10 kWh. Pulse output The PRO1 series DIN rail energy meter is equipped with a pulse output which is optically isolated from the inside circuit. It generates pulses in proportion to the measured consumption for purpose of remote reading or accuracy testing. The pulse output is a polarity dependant, open-collector transistor output requiring an external voltage source for correct operation. For this external voltage source, the voltage (Ui) should be lower than 27V DC, and the maximum switching current (Iimax) is 27mA. To connect the impulse output, connect 5-27V DC to connector 20 (collector), and the signal wire (S) to connector 21 (emitter). The pulse output depends on the version and is either 1000 or 2000 impulses per kWh. See section 1.3 for details regarding the impulses per kWh. ® 2011 -9- User manual 0014 1.12 Troubleshooting CAUTION During repair and maintenance, do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other conducting material as that will cause an electric shock and possibly cause injury. Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before opening the protection cover before working on it. Turn off and lock out all power supply to the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock. WARNING ® 2011 Maintenance or repair should only be performed by qualified personnel familiar with applicable codes and regulations. Use insulated tools to maintain or repair the meter. Make sure the protection cover is in place after maintenance or repair. The meter’s casing is sealed, if not properly looked after, this seal could be broken, voiding the warranty and damaging the meter. - 10 - User manual 0014 Problem Check Solution The consumption LED is not flashing (PULSE LED). Is there any load connected to the meter? Only if there is a load on the meter will this LED flash. Is the load on the line very low? The register doesn’t count. No pulse output. Pulse output rate wrong. ® 2011 If the load is very low, the time between 2 flashes is very long. This can be mistaken for a broken meter. As a test, an electric water boiler (~1600W) should make it blink once every second. Is the meter connected in reverse in case of a reverse enabled meter ? Swap the connecting wires to the meter (clamp 3 should be connected to load in and clamp 6 to load out) See section 1.10 for details. Maybe there is a fault inside the meter. Please contact technical support for a meter replacement. Is there almost no load on the meter? Check if the consumption led is blinking (see above). 200 flashes of the LED equals 0.1kWh or 0.2kWh and should be clearly visible on the display. Maybe there is a fault inside the meter. Please contact technical support for a meter replacement. Is DC power connected to the meter ? Check the external voltage source (Ui) is 5-27V DC. Is the pulse output connected correctly? Check correct connection: connect 5-27V DC to connection 20 (collector), and the signal wire (S) to connection 21(emitter). Maybe there is a fault inside the meter. Please contact technical support for a meter replacement. Maybe there is a fault inside the meter. Please contact technical support for a meter replacement. - 11 - User manual 0014 1.13 Technical support For questions about one of our products please contact: - The Inepro Metering dealer in your region Your local Inepro Metering distributor Email: [email protected] www.ineprometering.com ® 2011 - 12 - User manual 0014