Download Untitled
Transcript
Page 41 of 81 Report No.: 28210014 001 IEC 60335-2-80 Clause Requirement + Test Result - Remark Verdict N/A No contact between live parts and accessible metal parts and, for class II constructions, between live parts and metal parts separated from accessible metal parts by supplementary insulation only 26.6 Terminals for type X attachment and for connection to fixed wiring suitable for connection of conductors with required cross-sectional area according to table 13; rated current (A); nominal cross-sectional area (mm²)................................................................: Terminal block is suitable for 2 connection up to 2,5mm rated current < 3A P Terminals only suitable for a specially prepared cord N/A 26.7 Terminals for type X attachment accessible after removal of a cover or part of the enclosure N/A 26.8 Terminals for the connection to fixed wiring, including the earthing terminal, located close to each other P 26.9 Terminals of the pillar type constructed and located as specified P 26.10 Terminals with screw clamping and screwless terminals not used for flat twin tinsel cords, unless conductors ends fitted with a device suitable for screw terminals N/A Pull test of 5 N to the connection N/A For type Y and Z attachment: soldered, welded, crimped and similar connections may be used N/A For Class II appliances: the conductor so positioned or fixed that reliance is not placed on soldering, welding or crimping alone N/A For Class II appliances: soldering, welding or crimping alone used, barriers provided, clearances and creepage distances satisfactory if the conductor becomes free N/A 26.11 27 27.1 PROVISION FOR EARTHING P Accessible metal parts of Class 0I and I appliances, permanently and reliably connected to an earthing terminal or contact of the appliance inlet N/A Earthing terminals not connected to neutral terminal N/A Class 0, II and III appliances have no provision for earthing Safety extra-low voltage circuits not earthed, unless protective extra-low voltage circuits TRF No. IEC60335_2_80C P N/A TRF originator: KEMA