Report No.: 28210014 001
IEC 60335-2-80
Clause
Requirement + Test
Result - Remark
Verdict
N/A
No contact between live parts and accessible metal
parts and, for class II constructions, between live
parts and metal parts separated from accessible
metal parts by supplementary insulation only
26.6
Terminals for type X attachment and for connection
to fixed wiring suitable for connection of conductors
with required cross-sectional area according to
table 13; rated current (A); nominal cross-sectional
area (mm²)................................................................:
Terminal block is suitable for
2
connection up to 2,5mm
rated current < 3A
P
Terminals only suitable for a specially prepared cord
N/A
26.7
Terminals for type X attachment accessible after
removal of a cover or part of the enclosure
N/A
26.8
Terminals for the connection to fixed wiring, including
the earthing terminal, located close to each other
P
26.9
Terminals of the pillar type constructed and located
as specified
P
26.10
Terminals with screw clamping and screwless
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for
screw terminals
N/A
Pull test of 5 N to the connection
N/A
For type Y and Z attachment: soldered, welded,
crimped and similar connections may be used
N/A
For Class II appliances: the conductor so positioned
or fixed that reliance is not placed on soldering,
welding or crimping alone
N/A
For Class II appliances: soldering, welding or
crimping alone used, barriers provided, clearances
and creepage distances satisfactory if the conductor
becomes free
N/A
26.11
27
27.1
PROVISION FOR EARTHING
P
Accessible metal parts of Class 0I and I appliances,
permanently and reliably connected to an earthing
terminal or contact of the appliance inlet
N/A
Earthing terminals not connected to neutral terminal
N/A
Class 0, II and III appliances have no provision for
earthing
Safety extra-low voltage circuits not earthed, unless
protective extra-low voltage circuits
TRF No. IEC60335_2_80C
P
N/A
TRF originator: KEMA