Download User`s Manual - Atel Electronics

Transcript
--
Managed Media Converter User Manual
@@ACTION sys_mib
DESCRIPTION
"Read the value from the temperature sensor. It is a numerical
series
of 5. There is a difference of 0.5 Celsius degree between a level
and
its next one."
::= { rc2201SystemMIB 1 }
rc2201FanRPM OBJECT-TYPE
SYNTAX
INTEGER
ACCESS read-only
STATUS
mandatory
-@@ACTION sys_mib
DESCRIPTION
"Return an approximate RPM of the fan1 on the back panel. The
value less
than or equal to 4200 represents that the fan is operational, else
breakdown."
::= { rc2201SystemMIB 2 }
rc2201DevicePort OBJECT-TYPE
SYNTAX
DisplayString
ACCESS read-only
STATUS
mandatory
-@@ACTION sys_mib
DESCRIPTION
"Get the quantity of ports that this system owns now."
::= { rc2201SystemMIB 3 }
rc2201CaseIntrusion OBJECT-TYPE
SYNTAX
DisplayString
ACCESS read-only
STATUS
mandatory
-@@ACTION sys_mib
DESCRIPTION
"Detect the Case is opened or closed."
::= { rc2201SystemMIB 4 }
rc2201UARTTest
OBJECT-TYPE
SYNTAX
INTEGER(0|1)
ACCESS read-only
STATUS
mandatory
-@@ACTION sys_mib
DESCRIPTION
"UART test.
range (0|1)
1 - pass
0 - failure "
::= { rc2201SystemMIB 5 }
rc2201DramTest
SYNTAX
OBJECT-TYPE
INTEGER(0|1)
Publication date: January, 2007
Revision A2
181