Download User Manual - Axis Communications
Transcript
AXIS Q2901-E PT Mount Temperature Alarm Camera Detectors - Below (B): Triggers if the temperature falls below the level (C) that you have set in the Detection Temperature field. By default, minimum temperature in the zone is used as the base for temperature detection. + 000 000 000 000 A B C 000 000 000 000 000 B 00000 00000 - Increase:Triggers if the temperature (E) increases faster than the increase rate (F) during an increase time interval (for example, in the time between t1 and t2). The increase rate (F) is defined as number of degrees (in Celsius or Fahrenheit) during a set time interval. In the following example, the measurement points (G) between t1 and t2 trigger an Increase alarm. The Increase alarm for t1 and t2 is active between t2 and t3. The measurement points between t2 and t3 untrigger the Increase alarm). Detection type Increase 29