Download Diviner 2000 User Guide
Transcript
Part 1—The Diviner 2000 display unit and probe Calibrating Diviner 2000 Scaled Frequency (SF) 1 0.9 0.8 0.7 0.6 Equation of line: 0.5 0.4 0.3 0.2 SF = 0.2746*(volumetric water content^0.3314) + 0 R2 = 0.9985 0.1 0 0 10 20 30 40 50 Volumetric Soil Water Content (%) Figure 6—Diviner 2000 calibration equation for combined soil textures Working with the default calibration equation The default calibration equation is based on combined data gathered from sampling on sand, sandy loam and an organic potting soil. It is described in Figure 6. It is built into the Diviner 2000 display unit and is labeled as the calibration equation for soil type #01. If you chose to work with the default calibration equation, the data will show relative soil water changes in all soil types except for those on which the equation is based. In these soil types, the data will show absolute values. Relative data Most users use this form of measurement because they are interested in the relative changes in soil water dynamics for their daily irrigation management practices. This concept was introduced successfully with EnviroSCAN, Sentek Pty Ltd's continuous monitoring system. Almost all economic gains recorded with EnviroSCAN in commercial agriculture were made using the concept of ‘relative change’ in soil water dynamics. Based on this experience, Sentek Pty Ltd recommends that relative changes in volumetric soil moisture content based on the default calibration supplied, can be used to show the most important soil water trends. Sentek Pty Ltd ACN 007 916 672 Page 15